ABAP Select data from SAP table FMSF1080_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMSF1080_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMSF1080_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FMSF1080_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FMSF1080_S TYPE STANDARD TABLE OF FMSF1080_S,
      WA_FMSF1080_S TYPE FMSF1080_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FMSF1080_S> TYPE FMSF1080_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FMSF1080_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FMSF1080_S
  INTO TABLE IT_FMSF1080_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FMSF1080_S
*  INTO TABLE @DATA(IT_FMSF1080_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FMSF1080_S INDEX 1 INTO DATA(WA_FMSF1080_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FMSF1080_S ASSIGNING <FMSF1080_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMSF1080_S>-WA_FMSF1080 = 1.
<FMSF1080_S>-LAUFD = 1.
<FMSF1080_S>-LAUFI = 1.
<FMSF1080_S>-BUKRS = 1.
<FMSF1080_S>-BELNR = 1.
ENDLOOP.

LOOP AT IT_FMSF1080_S INTO WA_FMSF1080_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FMSF1080_S-PAY_FULL_DOC, sy-vline,
WA_FMSF1080_S-CHECK, sy-vline,
WA_FMSF1080_S-GJAHR, sy-vline,
WA_FMSF1080_S-BUDAT, sy-vline,
WA_FMSF1080_S-REC_DEPT_NAME1, sy-vline,
WA_FMSF1080_S-REC_DEPT_STREET, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMSF1080_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMSF1080_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMSF1080_S INTO WA_FMSF1080_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMSF1080_S-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMSF1080_S-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMSF1080_S-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMSF1080_S-GJAHR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMSF1080_S_STR,
WA_FMSF1080 TYPE STRING,
LAUFD TYPE STRING,
LAUFI TYPE STRING,
BUKRS TYPE STRING,
BELNR TYPE STRING,
PAY_FULL_DOC TYPE STRING,
CHECK TYPE STRING,
GJAHR TYPE STRING,
BUDAT TYPE STRING,
REC_DEPT_NAME1 TYPE STRING,
REC_DEPT_STREET TYPE STRING,
REC_DEPT_CITY TYPE STRING,
REC_DEPT_STATE TYPE STRING,
REC_DEPT_ZIP TYPE STRING,
CHRGD_DEPT_NAME1 TYPE STRING,
CHRGD_DEPT_STREET TYPE STRING,
CHRGD_DEPT_CITY TYPE STRING,
CHRGD_DEPT_STATE TYPE STRING,
CHRGD_DEPT_ZIP TYPE STRING,
CHECK_AMT TYPE STRING,
WAERS TYPE STRING,
T_SF1080DET TYPE STRING,
T_SF1080ACCT TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMSF1080_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMSF1080_S_STR-WA_FMSF1080 sy-vline
WA_FMSF1080_S_STR-LAUFD sy-vline
WA_FMSF1080_S_STR-LAUFI sy-vline
WA_FMSF1080_S_STR-BUKRS sy-vline
WA_FMSF1080_S_STR-BELNR sy-vline
WA_FMSF1080_S_STR-PAY_FULL_DOC sy-vline
WA_FMSF1080_S_STR-CHECK sy-vline
WA_FMSF1080_S_STR-GJAHR sy-vline
WA_FMSF1080_S_STR-BUDAT sy-vline
WA_FMSF1080_S_STR-REC_DEPT_NAME1 sy-vline
WA_FMSF1080_S_STR-REC_DEPT_STREET sy-vline
WA_FMSF1080_S_STR-REC_DEPT_CITY sy-vline
WA_FMSF1080_S_STR-REC_DEPT_STATE sy-vline
WA_FMSF1080_S_STR-REC_DEPT_ZIP sy-vline
WA_FMSF1080_S_STR-CHRGD_DEPT_NAME1 sy-vline
WA_FMSF1080_S_STR-CHRGD_DEPT_STREET sy-vline
WA_FMSF1080_S_STR-CHRGD_DEPT_CITY sy-vline
WA_FMSF1080_S_STR-CHRGD_DEPT_STATE sy-vline
WA_FMSF1080_S_STR-CHRGD_DEPT_ZIP sy-vline
WA_FMSF1080_S_STR-CHECK_AMT sy-vline
WA_FMSF1080_S_STR-WAERS sy-vline
WA_FMSF1080_S_STR-T_SF1080DET sy-vline
WA_FMSF1080_S_STR-T_SF1080ACCT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.