ABAP Select data from SAP table FMLCRUCT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMLCRUCT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMLCRUCT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FMLCRUCT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FMLCRUCT TYPE STANDARD TABLE OF FMLCRUCT,
      WA_FMLCRUCT TYPE FMLCRUCT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FMLCRUCT> TYPE FMLCRUCT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FMLCRUCT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FMLCRUCT
  INTO TABLE IT_FMLCRUCT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FMLCRUCT
*  INTO TABLE @DATA(IT_FMLCRUCT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FMLCRUCT INDEX 1 INTO DATA(WA_FMLCRUCT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FMLCRUCT ASSIGNING <FMLCRUCT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMLCRUCT>-MANDT = 1.
<FMLCRUCT>-BELNR = 1.
<FMLCRUCT>-KJAHR = 1.
<FMLCRUCT>-POSNR = 1.
<FMLCRUCT>-BDATJ = 1.
ENDLOOP.

LOOP AT IT_FMLCRUCT INTO WA_FMLCRUCT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FMLCRUCT-POPER, sy-vline,
WA_FMLCRUCT-CURTP, sy-vline,
WA_FMLCRUCT-WAERS, sy-vline,
WA_FMLCRUCT-SALK3, sy-vline,
WA_FMLCRUCT-SALK3_OLD, sy-vline,
WA_FMLCRUCT-SALKV, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMLCRUCT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMLCRUCT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMLCRUCT INTO WA_FMLCRUCT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMLCRUCT-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMLCRUCT-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field KJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMLCRUCT-KJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMLCRUCT-KJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field BDATJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMLCRUCT-BDATJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMLCRUCT-BDATJ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMLCRUCT_STR,
MANDT TYPE STRING,
BELNR TYPE STRING,
KJAHR TYPE STRING,
POSNR TYPE STRING,
BDATJ TYPE STRING,
POPER TYPE STRING,
CURTP TYPE STRING,
WAERS TYPE STRING,
SALK3 TYPE STRING,
SALK3_OLD TYPE STRING,
SALKV TYPE STRING,
SALKV_OLD TYPE STRING,
PEINH TYPE STRING,
PVPRS_OLD TYPE STRING,
STPRS_OLD TYPE STRING,
VPRSV_OLD TYPE STRING,
SDM_VERSION TYPE STRING,
BNBTR TYPE STRING,
EXBWR TYPE STRING,
VKWRT TYPE STRING,
VKWRA TYPE STRING,
EXVKW TYPE STRING,
VKSAL_OLD TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMLCRUCT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMLCRUCT_STR-MANDT sy-vline
WA_FMLCRUCT_STR-BELNR sy-vline
WA_FMLCRUCT_STR-KJAHR sy-vline
WA_FMLCRUCT_STR-POSNR sy-vline
WA_FMLCRUCT_STR-BDATJ sy-vline
WA_FMLCRUCT_STR-POPER sy-vline
WA_FMLCRUCT_STR-CURTP sy-vline
WA_FMLCRUCT_STR-WAERS sy-vline
WA_FMLCRUCT_STR-SALK3 sy-vline
WA_FMLCRUCT_STR-SALK3_OLD sy-vline
WA_FMLCRUCT_STR-SALKV sy-vline
WA_FMLCRUCT_STR-SALKV_OLD sy-vline
WA_FMLCRUCT_STR-PEINH sy-vline
WA_FMLCRUCT_STR-PVPRS_OLD sy-vline
WA_FMLCRUCT_STR-STPRS_OLD sy-vline
WA_FMLCRUCT_STR-VPRSV_OLD sy-vline
WA_FMLCRUCT_STR-SDM_VERSION sy-vline
WA_FMLCRUCT_STR-BNBTR sy-vline
WA_FMLCRUCT_STR-EXBWR sy-vline
WA_FMLCRUCT_STR-VKWRT sy-vline
WA_FMLCRUCT_STR-VKWRA sy-vline
WA_FMLCRUCT_STR-EXVKW sy-vline
WA_FMLCRUCT_STR-VKSAL_OLD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.