ABAP Select data from SAP table FMFGCLEARING into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMFGCLEARING table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMFGCLEARING. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FMFGCLEARING table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FMFGCLEARING TYPE STANDARD TABLE OF FMFGCLEARING,
      WA_FMFGCLEARING TYPE FMFGCLEARING,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FMFGCLEARING> TYPE FMFGCLEARING.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FMFGCLEARING.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FMFGCLEARING
  INTO TABLE IT_FMFGCLEARING.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FMFGCLEARING
*  INTO TABLE @DATA(IT_FMFGCLEARING2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FMFGCLEARING INDEX 1 INTO DATA(WA_FMFGCLEARING2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FMFGCLEARING ASSIGNING <FMFGCLEARING>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMFGCLEARING>-BUKRS = 1.
<FMFGCLEARING>-BELNR = 1.
<FMFGCLEARING>-GJAHR = 1.
<FMFGCLEARING>-BLDAT = 1.
<FMFGCLEARING>-BUDAT = 1.
ENDLOOP.

LOOP AT IT_FMFGCLEARING INTO WA_FMFGCLEARING.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FMFGCLEARING-BLART, sy-vline,
WA_FMFGCLEARING-HKONT, sy-vline,
WA_FMFGCLEARING-BSCHL, sy-vline,
WA_FMFGCLEARING-STBLG, sy-vline,
WA_FMFGCLEARING-USNAM, sy-vline,
ENDLOOP. *Add any further fields from structure WA_FMFGCLEARING you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMFGCLEARING TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMFGCLEARING INTO WA_FMFGCLEARING. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMFGCLEARING-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMFGCLEARING-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMFGCLEARING-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMFGCLEARING-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMFGCLEARING-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMFGCLEARING-HKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STBLG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMFGCLEARING-STBLG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMFGCLEARING-STBLG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMFGCLEARING_STR,
BUKRS TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BLDAT TYPE STRING,
BUDAT TYPE STRING,
BLART TYPE STRING,
HKONT TYPE STRING,
BSCHL TYPE STRING,
STBLG TYPE STRING,
USNAM TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMFGCLEARING_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMFGCLEARING_STR-BUKRS sy-vline
WA_FMFGCLEARING_STR-BELNR sy-vline
WA_FMFGCLEARING_STR-GJAHR sy-vline
WA_FMFGCLEARING_STR-BLDAT sy-vline
WA_FMFGCLEARING_STR-BUDAT sy-vline
WA_FMFGCLEARING_STR-BLART sy-vline
WA_FMFGCLEARING_STR-HKONT sy-vline
WA_FMFGCLEARING_STR-BSCHL sy-vline
WA_FMFGCLEARING_STR-STBLG sy-vline
WA_FMFGCLEARING_STR-USNAM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.