ABAP Select data from SAP table FMFCTR_EXT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMFCTR_EXT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMFCTR_EXT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FMFCTR_EXT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FMFCTR_EXT TYPE STANDARD TABLE OF FMFCTR_EXT,
      WA_FMFCTR_EXT TYPE FMFCTR_EXT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FMFCTR_EXT> TYPE FMFCTR_EXT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FMFCTR_EXT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FMFCTR_EXT
  INTO TABLE IT_FMFCTR_EXT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FMFCTR_EXT
*  INTO TABLE @DATA(IT_FMFCTR_EXT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FMFCTR_EXT INDEX 1 INTO DATA(WA_FMFCTR_EXT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FMFCTR_EXT ASSIGNING <FMFCTR_EXT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMFCTR_EXT>-AGCYCODE = 1.
<FMFCTR_EXT>-ORGCODE = 1.
<FMFCTR_EXT>-AGCYTYPE = 1.
<FMFCTR_EXT>-SUPTYPE = 1.
<FMFCTR_EXT>-REVUNIT = 1.
ENDLOOP.

LOOP AT IT_FMFCTR_EXT INTO WA_FMFCTR_EXT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FMFCTR_EXT-NEWPAY, sy-vline,
WA_FMFCTR_EXT-HBKID, sy-vline,
WA_FMFCTR_EXT-MINIS, sy-vline,
WA_FMFCTR_EXT-SECEST, sy-vline,
WA_FMFCTR_EXT-AREA, sy-vline,
WA_FMFCTR_EXT-SERFA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMFCTR_EXT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMFCTR_EXT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMFCTR_EXT INTO WA_FMFCTR_EXT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMFCTR_EXT_STR,
AGCYCODE TYPE STRING,
ORGCODE TYPE STRING,
AGCYTYPE TYPE STRING,
SUPTYPE TYPE STRING,
REVUNIT TYPE STRING,
NEWPAY TYPE STRING,
HBKID TYPE STRING,
MINIS TYPE STRING,
SECEST TYPE STRING,
AREA TYPE STRING,
SERFA TYPE STRING,
ORGAN TYPE STRING,
CAPI TYPE STRING,
DIVI TYPE STRING,
SUBD TYPE STRING,
TORC TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMFCTR_EXT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMFCTR_EXT_STR-AGCYCODE sy-vline
WA_FMFCTR_EXT_STR-ORGCODE sy-vline
WA_FMFCTR_EXT_STR-AGCYTYPE sy-vline
WA_FMFCTR_EXT_STR-SUPTYPE sy-vline
WA_FMFCTR_EXT_STR-REVUNIT sy-vline
WA_FMFCTR_EXT_STR-NEWPAY sy-vline
WA_FMFCTR_EXT_STR-HBKID sy-vline
WA_FMFCTR_EXT_STR-MINIS sy-vline
WA_FMFCTR_EXT_STR-SECEST sy-vline
WA_FMFCTR_EXT_STR-AREA sy-vline
WA_FMFCTR_EXT_STR-SERFA sy-vline
WA_FMFCTR_EXT_STR-ORGAN sy-vline
WA_FMFCTR_EXT_STR-CAPI sy-vline
WA_FMFCTR_EXT_STR-DIVI sy-vline
WA_FMFCTR_EXT_STR-SUBD sy-vline
WA_FMFCTR_EXT_STR-TORC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.