ABAP Select data from SAP table FMEUF_BKPF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMEUF_BKPF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMEUF_BKPF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FMEUF_BKPF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FMEUF_BKPF TYPE STANDARD TABLE OF FMEUF_BKPF,
      WA_FMEUF_BKPF TYPE FMEUF_BKPF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FMEUF_BKPF> TYPE FMEUF_BKPF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FMEUF_BKPF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FMEUF_BKPF
  INTO TABLE IT_FMEUF_BKPF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FMEUF_BKPF
*  INTO TABLE @DATA(IT_FMEUF_BKPF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FMEUF_BKPF INDEX 1 INTO DATA(WA_FMEUF_BKPF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FMEUF_BKPF ASSIGNING <FMEUF_BKPF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMEUF_BKPF>-AWTYP = 1.
<FMEUF_BKPF>-AWSYS = 1.
<FMEUF_BKPF>-AWKEY = 1.
<FMEUF_BKPF>-FINEXC = 1.
<FMEUF_BKPF>-BUKRS = 1.
ENDLOOP.

LOOP AT IT_FMEUF_BKPF INTO WA_FMEUF_BKPF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FMEUF_BKPF-BELNR, sy-vline,
WA_FMEUF_BKPF-GJAHR, sy-vline,
WA_FMEUF_BKPF-BLART, sy-vline,
WA_FMEUF_BKPF-BLDAT, sy-vline,
WA_FMEUF_BKPF-BUDAT, sy-vline,
WA_FMEUF_BKPF-WAERS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMEUF_BKPF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMEUF_BKPF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMEUF_BKPF INTO WA_FMEUF_BKPF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AWSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMEUF_BKPF-AWSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMEUF_BKPF-AWSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMEUF_BKPF-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMEUF_BKPF-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMEUF_BKPF-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMEUF_BKPF-GJAHR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMEUF_BKPF_STR,
AWTYP TYPE STRING,
AWSYS TYPE STRING,
AWKEY TYPE STRING,
FINEXC TYPE STRING,
BUKRS TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BLART TYPE STRING,
BLDAT TYPE STRING,
BUDAT TYPE STRING,
WAERS TYPE STRING,
HWAER TYPE STRING,
HWAE2 TYPE STRING,
HWAE3 TYPE STRING,
FIKRS TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMEUF_BKPF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMEUF_BKPF_STR-AWTYP sy-vline
WA_FMEUF_BKPF_STR-AWSYS sy-vline
WA_FMEUF_BKPF_STR-AWKEY sy-vline
WA_FMEUF_BKPF_STR-FINEXC sy-vline
WA_FMEUF_BKPF_STR-BUKRS sy-vline
WA_FMEUF_BKPF_STR-BELNR sy-vline
WA_FMEUF_BKPF_STR-GJAHR sy-vline
WA_FMEUF_BKPF_STR-BLART sy-vline
WA_FMEUF_BKPF_STR-BLDAT sy-vline
WA_FMEUF_BKPF_STR-BUDAT sy-vline
WA_FMEUF_BKPF_STR-WAERS sy-vline
WA_FMEUF_BKPF_STR-HWAER sy-vline
WA_FMEUF_BKPF_STR-HWAE2 sy-vline
WA_FMEUF_BKPF_STR-HWAE3 sy-vline
WA_FMEUF_BKPF_STR-FIKRS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.