ABAP Select data from SAP table FKNVA_ADDR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKNVA_ADDR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKNVA_ADDR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKNVA_ADDR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKNVA_ADDR TYPE STANDARD TABLE OF FKNVA_ADDR,
      WA_FKNVA_ADDR TYPE FKNVA_ADDR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKNVA_ADDR> TYPE FKNVA_ADDR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKNVA_ADDR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKNVA_ADDR
  INTO TABLE IT_FKNVA_ADDR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKNVA_ADDR
*  INTO TABLE @DATA(IT_FKNVA_ADDR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKNVA_ADDR INDEX 1 INTO DATA(WA_FKNVA_ADDR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKNVA_ADDR ASSIGNING <FKNVA_ADDR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKNVA_ADDR>-MANDT = 1.
<FKNVA_ADDR>-KUNNR = 1.
<FKNVA_ADDR>-ADRNR = 1.
<FKNVA_ADDR>-ABLAD = 1.
<FKNVA_ADDR>-LFDNR = 1.
ENDLOOP.

LOOP AT IT_FKNVA_ADDR INTO WA_FKNVA_ADDR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKNVA_ADDR-KNFAK, sy-vline,
WA_FKNVA_ADDR-WANID, sy-vline,
WA_FKNVA_ADDR-MOAB1, sy-vline,
WA_FKNVA_ADDR-MOBI1, sy-vline,
WA_FKNVA_ADDR-MOAB2, sy-vline,
WA_FKNVA_ADDR-MOBI2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKNVA_ADDR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKNVA_ADDR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKNVA_ADDR INTO WA_FKNVA_ADDR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKNVA_ADDR-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKNVA_ADDR-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKNVA_ADDR-ADRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKNVA_ADDR-ADRNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKNVA_ADDR_STR,
MANDT TYPE STRING,
KUNNR TYPE STRING,
ADRNR TYPE STRING,
ABLAD TYPE STRING,
LFDNR TYPE STRING,
KNFAK TYPE STRING,
WANID TYPE STRING,
MOAB1 TYPE STRING,
MOBI1 TYPE STRING,
MOAB2 TYPE STRING,
MOBI2 TYPE STRING,
DIAB1 TYPE STRING,
DIBI1 TYPE STRING,
DIAB2 TYPE STRING,
DIBI2 TYPE STRING,
MIAB1 TYPE STRING,
MIBI1 TYPE STRING,
MIAB2 TYPE STRING,
MIBI2 TYPE STRING,
DOAB1 TYPE STRING,
DOBI1 TYPE STRING,
DOAB2 TYPE STRING,
DOBI2 TYPE STRING,
FRAB1 TYPE STRING,
FRBI1 TYPE STRING,
FRAB2 TYPE STRING,
FRBI2 TYPE STRING,
SAAB1 TYPE STRING,
SABI1 TYPE STRING,
SAAB2 TYPE STRING,
SABI2 TYPE STRING,
SOAB1 TYPE STRING,
SOBI1 TYPE STRING,
SOAB2 TYPE STRING,
SOBI2 TYPE STRING,
DEFAB TYPE STRING,
KZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKNVA_ADDR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKNVA_ADDR_STR-MANDT sy-vline
WA_FKNVA_ADDR_STR-KUNNR sy-vline
WA_FKNVA_ADDR_STR-ADRNR sy-vline
WA_FKNVA_ADDR_STR-ABLAD sy-vline
WA_FKNVA_ADDR_STR-LFDNR sy-vline
WA_FKNVA_ADDR_STR-KNFAK sy-vline
WA_FKNVA_ADDR_STR-WANID sy-vline
WA_FKNVA_ADDR_STR-MOAB1 sy-vline
WA_FKNVA_ADDR_STR-MOBI1 sy-vline
WA_FKNVA_ADDR_STR-MOAB2 sy-vline
WA_FKNVA_ADDR_STR-MOBI2 sy-vline
WA_FKNVA_ADDR_STR-DIAB1 sy-vline
WA_FKNVA_ADDR_STR-DIBI1 sy-vline
WA_FKNVA_ADDR_STR-DIAB2 sy-vline
WA_FKNVA_ADDR_STR-DIBI2 sy-vline
WA_FKNVA_ADDR_STR-MIAB1 sy-vline
WA_FKNVA_ADDR_STR-MIBI1 sy-vline
WA_FKNVA_ADDR_STR-MIAB2 sy-vline
WA_FKNVA_ADDR_STR-MIBI2 sy-vline
WA_FKNVA_ADDR_STR-DOAB1 sy-vline
WA_FKNVA_ADDR_STR-DOBI1 sy-vline
WA_FKNVA_ADDR_STR-DOAB2 sy-vline
WA_FKNVA_ADDR_STR-DOBI2 sy-vline
WA_FKNVA_ADDR_STR-FRAB1 sy-vline
WA_FKNVA_ADDR_STR-FRBI1 sy-vline
WA_FKNVA_ADDR_STR-FRAB2 sy-vline
WA_FKNVA_ADDR_STR-FRBI2 sy-vline
WA_FKNVA_ADDR_STR-SAAB1 sy-vline
WA_FKNVA_ADDR_STR-SABI1 sy-vline
WA_FKNVA_ADDR_STR-SAAB2 sy-vline
WA_FKNVA_ADDR_STR-SABI2 sy-vline
WA_FKNVA_ADDR_STR-SOAB1 sy-vline
WA_FKNVA_ADDR_STR-SOBI1 sy-vline
WA_FKNVA_ADDR_STR-SOAB2 sy-vline
WA_FKNVA_ADDR_STR-SOBI2 sy-vline
WA_FKNVA_ADDR_STR-DEFAB sy-vline
WA_FKNVA_ADDR_STR-KZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.