ABAP Select data from SAP table FKKCIBW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKCIBW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKCIBW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKKCIBW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKKCIBW TYPE STANDARD TABLE OF FKKCIBW,
      WA_FKKCIBW TYPE FKKCIBW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKKCIBW> TYPE FKKCIBW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKKCIBW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKKCIBW
  INTO TABLE IT_FKKCIBW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKKCIBW
*  INTO TABLE @DATA(IT_FKKCIBW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKKCIBW INDEX 1 INTO DATA(WA_FKKCIBW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKKCIBW ASSIGNING <FKKCIBW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKCIBW>-BUKRS = 1.
<FKKCIBW>-SPART = 1.
<FKKCIBW>-BETRW = 1.
<FKKCIBW>-WAERS = 1.
<FKKCIBW>-AUGRD = 1.
ENDLOOP.

LOOP AT IT_FKKCIBW INTO WA_FKKCIBW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKKCIBW-MAHNV, sy-vline,
WA_FKKCIBW-MAHNS, sy-vline,
WA_FKKCIBW-BETRH, sy-vline,
WA_FKKCIBW-HWAER, sy-vline,
WA_FKKCIBW-GSBER, sy-vline,
WA_FKKCIBW-BUDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKCIBW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKCIBW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKCIBW INTO WA_FKKCIBW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKCIBW-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKCIBW-GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKCIBW-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKCIBW-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADDRNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKCIBW-ADDRNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKCIBW-ADDRNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIL, internal->external for field FIPEX CALL FUNCTION 'CONVERSION_EXIT_FMCIL_OUTPUT' EXPORTING input = WA_FKKCIBW-FIPEX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKCIBW-FIPEX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKCIBW-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKCIBW-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKCIBW_STR,
BUKRS TYPE STRING,
SPART TYPE STRING,
BETRW TYPE STRING,
WAERS TYPE STRING,
AUGRD TYPE STRING,
MAHNV TYPE STRING,
MAHNS TYPE STRING,
BETRH TYPE STRING,
HWAER TYPE STRING,
GSBER TYPE STRING,
BUDAT TYPE STRING,
FAEDN TYPE STRING,
AUGDT TYPE STRING,
GPART TYPE STRING,
VKONT TYPE STRING,
ADDRNUMBER TYPE STRING,
POST_CODE1 TYPE STRING,
COUNTRY TYPE STRING,
DELAY TYPE STRING,
FIPEX TYPE STRING,
FISTL TYPE STRING,
FONDS TYPE STRING,
FKBER TYPE STRING,
MEASURE TYPE STRING,
GRANT_NBR TYPE STRING,
ORIGFIKRS TYPE STRING,
BUDGET_PD TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKCIBW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKCIBW_STR-BUKRS sy-vline
WA_FKKCIBW_STR-SPART sy-vline
WA_FKKCIBW_STR-BETRW sy-vline
WA_FKKCIBW_STR-WAERS sy-vline
WA_FKKCIBW_STR-AUGRD sy-vline
WA_FKKCIBW_STR-MAHNV sy-vline
WA_FKKCIBW_STR-MAHNS sy-vline
WA_FKKCIBW_STR-BETRH sy-vline
WA_FKKCIBW_STR-HWAER sy-vline
WA_FKKCIBW_STR-GSBER sy-vline
WA_FKKCIBW_STR-BUDAT sy-vline
WA_FKKCIBW_STR-FAEDN sy-vline
WA_FKKCIBW_STR-AUGDT sy-vline
WA_FKKCIBW_STR-GPART sy-vline
WA_FKKCIBW_STR-VKONT sy-vline
WA_FKKCIBW_STR-ADDRNUMBER sy-vline
WA_FKKCIBW_STR-POST_CODE1 sy-vline
WA_FKKCIBW_STR-COUNTRY sy-vline
WA_FKKCIBW_STR-DELAY sy-vline
WA_FKKCIBW_STR-FIPEX sy-vline
WA_FKKCIBW_STR-FISTL sy-vline
WA_FKKCIBW_STR-FONDS sy-vline
WA_FKKCIBW_STR-FKBER sy-vline
WA_FKKCIBW_STR-MEASURE sy-vline
WA_FKKCIBW_STR-GRANT_NBR sy-vline
WA_FKKCIBW_STR-ORIGFIKRS sy-vline
WA_FKKCIBW_STR-BUDGET_PD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.