ABAP Select data from SAP table FKKCC_ADDITIONAL_ATTRIB_DESC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKCC_ADDITIONAL_ATTRIB_DESC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKCC_ADDITIONAL_ATTRIB_DESC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKKCC_ADDITIONAL_ATTRIB_DESC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKKCC_ADDITIONAL_ATTRIB_DESC TYPE STANDARD TABLE OF FKKCC_ADDITIONAL_ATTRIB_DESC,
      WA_FKKCC_ADDITIONAL_ATTRIB_DESC TYPE FKKCC_ADDITIONAL_ATTRIB_DESC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKKCC_ADDITIONAL_ATTRIB_DESC> TYPE FKKCC_ADDITIONAL_ATTRIB_DESC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKKCC_ADDITIONAL_ATTRIB_DESC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKKCC_ADDITIONAL_ATTRIB_DESC
  INTO TABLE IT_FKKCC_ADDITIONAL_ATTRIB_DESC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKKCC_ADDITIONAL_ATTRIB_DESC
*  INTO TABLE @DATA(IT_FKKCC_ADDITIONAL_ATTRIB_DESC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKKCC_ADDITIONAL_ATTRIB_DESC INDEX 1 INTO DATA(WA_FKKCC_ADDITIONAL_ATTRIB_DESC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKKCC_ADDITIONAL_ATTRIB_DESC ASSIGNING <FKKCC_ADDITIONAL_ATTRIB_DESC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKCC_ADDITIONAL_ATTRIB_DESC>-CONTROLLER = 1.
<FKKCC_ADDITIONAL_ATTRIB_DESC>-NAME = 1.
<FKKCC_ADDITIONAL_ATTRIB_DESC>-CHOICE = 1.
<FKKCC_ADDITIONAL_ATTRIB_DESC>-SELECTION = 1.
<FKKCC_ADDITIONAL_ATTRIB_DESC>-CONTROLLER = 1.
ENDLOOP.

LOOP AT IT_FKKCC_ADDITIONAL_ATTRIB_DESC INTO WA_FKKCC_ADDITIONAL_ATTRIB_DESC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKKCC_ADDITIONAL_ATTRIB_DESC-PATTERN, sy-vline,
WA_FKKCC_ADDITIONAL_ATTRIB_DESC-STRING_ENUMERATION, sy-vline,
WA_FKKCC_ADDITIONAL_ATTRIB_DESC-CONTROLLER, sy-vline,
WA_FKKCC_ADDITIONAL_ATTRIB_DESC-VALUE, sy-vline,
WA_FKKCC_ADDITIONAL_ATTRIB_DESC-NUMBER_ENUMERATION, sy-vline,
WA_FKKCC_ADDITIONAL_ATTRIB_DESC-CONTROLLER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKCC_ADDITIONAL_ATTRIB_DESC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKCC_ADDITIONAL_ATTRIB_DESC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKCC_ADDITIONAL_ATTRIB_DESC INTO WA_FKKCC_ADDITIONAL_ATTRIB_DESC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKCC_ADDITIONAL_ATTRIB_DESC_STR,
CONTROLLER TYPE STRING,
NAME TYPE STRING,
CHOICE TYPE STRING,
SELECTION TYPE STRING,
CONTROLLER TYPE STRING,
PATTERN TYPE STRING,
STRING_ENUMERATION TYPE STRING,
CONTROLLER TYPE STRING,
VALUE TYPE STRING,
NUMBER_ENUMERATION TYPE STRING,
CONTROLLER TYPE STRING,
VALUE TYPE STRING,
DATE_ENUMERATION TYPE STRING,
CONTROLLER TYPE STRING,
VALUE TYPE STRING,
NUMBER_RANGE TYPE STRING,
CONTROLLER TYPE STRING,
MIN TYPE STRING,
CONTROLLER TYPE STRING,
INCLUDED TYPE STRING,
CONTENT TYPE STRING,
MAX TYPE STRING,
CONTROLLER TYPE STRING,
INCLUDED TYPE STRING,
CONTENT TYPE STRING,
DATE_RANGE TYPE STRING,
CONTROLLER TYPE STRING,
MIN TYPE STRING,
CONTROLLER TYPE STRING,
INCLUDED TYPE STRING,
CONTENT TYPE STRING,
MAX TYPE STRING,
CONTROLLER TYPE STRING,
INCLUDED TYPE STRING,
CONTENT TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-NAME sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CHOICE sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-SELECTION sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-PATTERN sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-STRING_ENUMERATION sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-VALUE sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-NUMBER_ENUMERATION sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-VALUE sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-DATE_ENUMERATION sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-VALUE sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-NUMBER_RANGE sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-MIN sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-INCLUDED sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTENT sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-MAX sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-INCLUDED sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTENT sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-DATE_RANGE sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-MIN sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-INCLUDED sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTENT sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-MAX sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTROLLER sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-INCLUDED sy-vline
WA_FKKCC_ADDITIONAL_ATTRIB_DESC_STR-CONTENT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.