ABAP Select data from SAP table FKKBIXBIT_SEL_IT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKBIXBIT_SEL_IT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKBIXBIT_SEL_IT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKKBIXBIT_SEL_IT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKKBIXBIT_SEL_IT TYPE STANDARD TABLE OF FKKBIXBIT_SEL_IT,
      WA_FKKBIXBIT_SEL_IT TYPE FKKBIXBIT_SEL_IT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKKBIXBIT_SEL_IT> TYPE FKKBIXBIT_SEL_IT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKKBIXBIT_SEL_IT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKKBIXBIT_SEL_IT
  INTO TABLE IT_FKKBIXBIT_SEL_IT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKKBIXBIT_SEL_IT
*  INTO TABLE @DATA(IT_FKKBIXBIT_SEL_IT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKKBIXBIT_SEL_IT INDEX 1 INTO DATA(WA_FKKBIXBIT_SEL_IT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKKBIXBIT_SEL_IT ASSIGNING <FKKBIXBIT_SEL_IT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKBIXBIT_SEL_IT>-GPART_RTAB = 1.
<FKKBIXBIT_SEL_IT>-VKONT_RTAB = 1.
<FKKBIXBIT_SEL_IT>-VKONT_GPART_RTAB = 1.
<FKKBIXBIT_SEL_IT>-SRCTATYPE_RTAB = 1.
<FKKBIXBIT_SEL_IT>-SRCTAID_RTAB = 1.
ENDLOOP.

LOOP AT IT_FKKBIXBIT_SEL_IT INTO WA_FKKBIXBIT_SEL_IT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKKBIXBIT_SEL_IT-BITSTATUS_RTAB, sy-vline,
WA_FKKBIXBIT_SEL_IT-BITCAT_RTAB, sy-vline,
WA_FKKBIXBIT_SEL_IT-BITDATE_RTAB, sy-vline,
WA_FKKBIXBIT_SEL_IT-BITTIME_RTAB, sy-vline,
WA_FKKBIXBIT_SEL_IT-BITCRDATE_RTAB, sy-vline,
WA_FKKBIXBIT_SEL_IT-SUBPROCESS_RTAB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKBIXBIT_SEL_IT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKBIXBIT_SEL_IT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKBIXBIT_SEL_IT INTO WA_FKKBIXBIT_SEL_IT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKBIXBIT_SEL_IT_STR,
GPART_RTAB TYPE STRING,
VKONT_RTAB TYPE STRING,
VKONT_GPART_RTAB TYPE STRING,
SRCTATYPE_RTAB TYPE STRING,
SRCTAID_RTAB TYPE STRING,
BITSTATUS_RTAB TYPE STRING,
BITCAT_RTAB TYPE STRING,
BITDATE_RTAB TYPE STRING,
BITTIME_RTAB TYPE STRING,
BITCRDATE_RTAB TYPE STRING,
SUBPROCESS_RTAB TYPE STRING,
BITTYPE_RTAB TYPE STRING,
INVDOCNO_RTAB TYPE STRING,
BILLDOCNO_RTAB TYPE STRING,
INVBILL_CRDATE_UNINV_TAB TYPE STRING,
BILLDOCNO_UNINV_RTAB TYPE STRING,
INVBILL_CRDATE_TAB TYPE STRING,
USE_BILLDOCNO_UNINV TYPE STRING,
BILLCRDATE_RTAB TYPE STRING,
BILL_FIRST_RTAB TYPE STRING,
MDCAT_RTAB TYPE STRING,
PREPAID_RTAB TYPE STRING,
BITREVERSED_RTAB TYPE STRING,
BITREVERSAL_RTAB TYPE STRING,
BILLREVERSED_RTAB TYPE STRING,
BILLREVERSAL_RTAB TYPE STRING,
FURTHER_SEL_TAB TYPE STRING,
NO_COLLECT TYPE STRING,
BIXBIT_DBTAB_TAB TYPE STRING,
RECORDS TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKBIXBIT_SEL_IT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKBIXBIT_SEL_IT_STR-GPART_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-VKONT_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-VKONT_GPART_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-SRCTATYPE_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-SRCTAID_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BITSTATUS_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BITCAT_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BITDATE_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BITTIME_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BITCRDATE_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-SUBPROCESS_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BITTYPE_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-INVDOCNO_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BILLDOCNO_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-INVBILL_CRDATE_UNINV_TAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BILLDOCNO_UNINV_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-INVBILL_CRDATE_TAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-USE_BILLDOCNO_UNINV sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BILLCRDATE_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BILL_FIRST_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-MDCAT_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-PREPAID_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BITREVERSED_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BITREVERSAL_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BILLREVERSED_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BILLREVERSAL_RTAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-FURTHER_SEL_TAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-NO_COLLECT sy-vline
WA_FKKBIXBIT_SEL_IT_STR-BIXBIT_DBTAB_TAB sy-vline
WA_FKKBIXBIT_SEL_IT_STR-RECORDS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.