ABAP Select data from SAP table FKKBIX_UPLOAD_DISP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKBIX_UPLOAD_DISP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKBIX_UPLOAD_DISP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKKBIX_UPLOAD_DISP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKKBIX_UPLOAD_DISP TYPE STANDARD TABLE OF FKKBIX_UPLOAD_DISP,
      WA_FKKBIX_UPLOAD_DISP TYPE FKKBIX_UPLOAD_DISP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKKBIX_UPLOAD_DISP> TYPE FKKBIX_UPLOAD_DISP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKKBIX_UPLOAD_DISP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKKBIX_UPLOAD_DISP
  INTO TABLE IT_FKKBIX_UPLOAD_DISP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKKBIX_UPLOAD_DISP
*  INTO TABLE @DATA(IT_FKKBIX_UPLOAD_DISP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKKBIX_UPLOAD_DISP INDEX 1 INTO DATA(WA_FKKBIX_UPLOAD_DISP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKKBIX_UPLOAD_DISP ASSIGNING <FKKBIX_UPLOAD_DISP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKBIX_UPLOAD_DISP>-SOURCE = 1.
<FKKBIX_UPLOAD_DISP>-SOURCE_TYPE = 1.
<FKKBIX_UPLOAD_DISP>-UPLOAD_SCHEMA = 1.
<FKKBIX_UPLOAD_DISP>-CPCODEPAGE = 1.
<FKKBIX_UPLOAD_DISP>-DELIMITER = 1.
ENDLOOP.

LOOP AT IT_FKKBIX_UPLOAD_DISP INTO WA_FKKBIX_UPLOAD_DISP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKKBIX_UPLOAD_DISP-START_LINE, sy-vline,
WA_FKKBIX_UPLOAD_DISP-DECIMAL_SEPARATOR, sy-vline,
WA_FKKBIX_UPLOAD_DISP-THOUSAND_SEPARATOR, sy-vline,
WA_FKKBIX_UPLOAD_DISP-UPL_COMMENT, sy-vline,
WA_FKKBIX_UPLOAD_DISP-DATE_FORMAT, sy-vline,
WA_FKKBIX_UPLOAD_DISP-SETTINGS_PROG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKBIX_UPLOAD_DISP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKBIX_UPLOAD_DISP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKBIX_UPLOAD_DISP INTO WA_FKKBIX_UPLOAD_DISP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKBIX_UPLOAD_DISP_STR,
SOURCE TYPE STRING,
SOURCE_TYPE TYPE STRING,
UPLOAD_SCHEMA TYPE STRING,
CPCODEPAGE TYPE STRING,
DELIMITER TYPE STRING,
START_LINE TYPE STRING,
DECIMAL_SEPARATOR TYPE STRING,
THOUSAND_SEPARATOR TYPE STRING,
UPL_COMMENT TYPE STRING,
DATE_FORMAT TYPE STRING,
SETTINGS_PROG TYPE STRING,
SETTINGS_DYNP TYPE STRING,
COLUMN_SEPARATOR TYPE STRING,
RECORDTYPE_IDENTIFIER TYPE STRING,
REPORTNAME TYPE STRING,
FUBA_READ TYPE STRING,
FUBA_LOAD TYPE STRING,
FUBA_SAMPLE TYPE STRING,
DOCU TYPE STRING,
UPLOAD_SCHEMA_TEXT TYPE STRING,
SOURCE_TYPE_TEXT TYPE STRING,
CPCOMMENT TYPE STRING,
DECIMAL_SEPARATOR_TXT TYPE STRING,
THOUSAND_SEPARATOR_TXT TYPE STRING,
COLUMN_SEPARATOR_TXT TYPE STRING,
DELIMITER_TXT TYPE STRING,
RECORDTYPE_IDENTIFIER_TXT TYPE STRING,
DATE_FORMAT_TXT TYPE STRING,
ADD_PARAMS TYPE STRING,
EXT_REF32 TYPE STRING,
TEXT60 TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKBIX_UPLOAD_DISP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-SOURCE sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-SOURCE_TYPE sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-UPLOAD_SCHEMA sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-CPCODEPAGE sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-DELIMITER sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-START_LINE sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-DECIMAL_SEPARATOR sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-THOUSAND_SEPARATOR sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-UPL_COMMENT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-DATE_FORMAT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-SETTINGS_PROG sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-SETTINGS_DYNP sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-COLUMN_SEPARATOR sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-RECORDTYPE_IDENTIFIER sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-REPORTNAME sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-FUBA_READ sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-FUBA_LOAD sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-FUBA_SAMPLE sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-DOCU sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-UPLOAD_SCHEMA_TEXT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-SOURCE_TYPE_TEXT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-CPCOMMENT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-DECIMAL_SEPARATOR_TXT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-THOUSAND_SEPARATOR_TXT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-COLUMN_SEPARATOR_TXT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-DELIMITER_TXT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-RECORDTYPE_IDENTIFIER_TXT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-DATE_FORMAT_TXT sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-ADD_PARAMS sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-EXT_REF32 sy-vline
WA_FKKBIX_UPLOAD_DISP_STR-TEXT60 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.