ABAP Select data from SAP table FKKBIX_UPLOAD_BIT_RESULT_CNT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKBIX_UPLOAD_BIT_RESULT_CNT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKBIX_UPLOAD_BIT_RESULT_CNT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKKBIX_UPLOAD_BIT_RESULT_CNT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKKBIX_UPLOAD_BIT_RESULT_CNT TYPE STANDARD TABLE OF FKKBIX_UPLOAD_BIT_RESULT_CNT,
      WA_FKKBIX_UPLOAD_BIT_RESULT_CNT TYPE FKKBIX_UPLOAD_BIT_RESULT_CNT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKKBIX_UPLOAD_BIT_RESULT_CNT> TYPE FKKBIX_UPLOAD_BIT_RESULT_CNT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKKBIX_UPLOAD_BIT_RESULT_CNT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKKBIX_UPLOAD_BIT_RESULT_CNT
  INTO TABLE IT_FKKBIX_UPLOAD_BIT_RESULT_CNT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKKBIX_UPLOAD_BIT_RESULT_CNT
*  INTO TABLE @DATA(IT_FKKBIX_UPLOAD_BIT_RESULT_CNT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKKBIX_UPLOAD_BIT_RESULT_CNT INDEX 1 INTO DATA(WA_FKKBIX_UPLOAD_BIT_RESULT_CNT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKKBIX_UPLOAD_BIT_RESULT_CNT ASSIGNING <FKKBIX_UPLOAD_BIT_RESULT_CNT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKBIX_UPLOAD_BIT_RESULT_CNT>-IT = 1.
<FKKBIX_UPLOAD_BIT_RESULT_CNT>-PY = 1.
<FKKBIX_UPLOAD_BIT_RESULT_CNT>-TX = 1.
<FKKBIX_UPLOAD_BIT_RESULT_CNT>-TT = 1.
<FKKBIX_UPLOAD_BIT_RESULT_CNT>-IT0 = 1.
ENDLOOP.

LOOP AT IT_FKKBIX_UPLOAD_BIT_RESULT_CNT INTO WA_FKKBIX_UPLOAD_BIT_RESULT_CNT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKKBIX_UPLOAD_BIT_RESULT_CNT-PY0, sy-vline,
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT-TX0, sy-vline,
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT-TT0, sy-vline,
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT-IT1, sy-vline,
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT-PY1, sy-vline,
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT-TX1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKBIX_UPLOAD_BIT_RESULT_CNT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKBIX_UPLOAD_BIT_RESULT_CNT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKBIX_UPLOAD_BIT_RESULT_CNT INTO WA_FKKBIX_UPLOAD_BIT_RESULT_CNT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR,
IT TYPE STRING,
PY TYPE STRING,
TX TYPE STRING,
TT TYPE STRING,
IT0 TYPE STRING,
PY0 TYPE STRING,
TX0 TYPE STRING,
TT0 TYPE STRING,
IT1 TYPE STRING,
PY1 TYPE STRING,
TX1 TYPE STRING,
TT1 TYPE STRING,
IT3 TYPE STRING,
PY3 TYPE STRING,
TX3 TYPE STRING,
TT3 TYPE STRING,
IT_ERR TYPE STRING,
PY_ERR TYPE STRING,
TX_ERR TYPE STRING,
TT_ERR TYPE STRING,
SRCTA TYPE STRING,
SRCTA_ERR TYPE STRING,
BILLDOCNO TYPE STRING,
INVDOCNO TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-IT sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-PY sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-TX sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-TT sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-IT0 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-PY0 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-TX0 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-TT0 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-IT1 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-PY1 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-TX1 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-TT1 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-IT3 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-PY3 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-TX3 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-TT3 sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-IT_ERR sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-PY_ERR sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-TX_ERR sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-TT_ERR sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-SRCTA sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-SRCTA_ERR sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-BILLDOCNO sy-vline
WA_FKKBIX_UPLOAD_BIT_RESULT_CNT_STR-INVDOCNO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.