ABAP Select data from SAP table FKKBIX_RATING_BIT_PY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKBIX_RATING_BIT_PY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKBIX_RATING_BIT_PY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKKBIX_RATING_BIT_PY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKKBIX_RATING_BIT_PY TYPE STANDARD TABLE OF FKKBIX_RATING_BIT_PY,
      WA_FKKBIX_RATING_BIT_PY TYPE FKKBIX_RATING_BIT_PY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKKBIX_RATING_BIT_PY> TYPE FKKBIX_RATING_BIT_PY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKKBIX_RATING_BIT_PY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKKBIX_RATING_BIT_PY
  INTO TABLE IT_FKKBIX_RATING_BIT_PY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKKBIX_RATING_BIT_PY
*  INTO TABLE @DATA(IT_FKKBIX_RATING_BIT_PY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKKBIX_RATING_BIT_PY INDEX 1 INTO DATA(WA_FKKBIX_RATING_BIT_PY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKKBIX_RATING_BIT_PY ASSIGNING <FKKBIX_RATING_BIT_PY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKBIX_RATING_BIT_PY>-BITNO = 1.
<FKKBIX_RATING_BIT_PY>-BITCAT = 1.
<FKKBIX_RATING_BIT_PY>-SRCTATYPE = 1.
<FKKBIX_RATING_BIT_PY>-SRCTAID = 1.
<FKKBIX_RATING_BIT_PY>-VKONT = 1.
ENDLOOP.

LOOP AT IT_FKKBIX_RATING_BIT_PY INTO WA_FKKBIX_RATING_BIT_PY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKKBIX_RATING_BIT_PY-PYMET, sy-vline,
WA_FKKBIX_RATING_BIT_PY-EMBVT, sy-vline,
WA_FKKBIX_RATING_BIT_PY-EMGPA, sy-vline,
WA_FKKBIX_RATING_BIT_PY-PCARD_GUID, sy-vline,
WA_FKKBIX_RATING_BIT_PY-PCARD_GUID32, sy-vline,
WA_FKKBIX_RATING_BIT_PY-PCARD_XSETT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKBIX_RATING_BIT_PY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKBIX_RATING_BIT_PY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKBIX_RATING_BIT_PY INTO WA_FKKBIX_RATING_BIT_PY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SRCTAID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKBIX_RATING_BIT_PY-SRCTAID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKBIX_RATING_BIT_PY-SRCTAID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKBIX_RATING_BIT_PY-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKBIX_RATING_BIT_PY-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EMGPA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKBIX_RATING_BIT_PY-EMGPA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKBIX_RATING_BIT_PY-EMGPA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EMADR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKBIX_RATING_BIT_PY-EMADR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKBIX_RATING_BIT_PY-EMADR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKBIX_RATING_BIT_PY_STR,
BITNO TYPE STRING,
BITCAT TYPE STRING,
SRCTATYPE TYPE STRING,
SRCTAID TYPE STRING,
VKONT TYPE STRING,
PYMET TYPE STRING,
EMBVT TYPE STRING,
EMGPA TYPE STRING,
PCARD_GUID TYPE STRING,
PCARD_GUID32 TYPE STRING,
PCARD_XSETT TYPE STRING,
PYREF TYPE STRING,
PY_AMOUNT TYPE STRING,
PY_CURR TYPE STRING,
PY_PRIO TYPE STRING,
BITREF32 TYPE STRING,
PY_GROUP TYPE STRING,
CCARD_ID TYPE STRING,
CCINS TYPE STRING,
CCNUM TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,
CCNAME TYPE STRING,
CGUID TYPE STRING,
ENCTP TYPE STRING,
AUNUM TYPE STRING,
AUTRA TYPE STRING,
AUDAT TYPE STRING,
AUTIM TYPE STRING,
AUTWR TYPE STRING,
CCWAE TYPE STRING,
MERCH TYPE STRING,
EXPDT TYPE STRING,
EXPTM TYPE STRING,
EXTMP TYPE STRING,
AUTMP TYPE STRING,
AUCID TYPE STRING,
AVREF TYPE STRING,
EMADR TYPE STRING,
EMCRD TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKBIX_RATING_BIT_PY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-BITNO sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-BITCAT sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-SRCTATYPE sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-SRCTAID sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-VKONT sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-PYMET sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-EMBVT sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-EMGPA sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-PCARD_GUID sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-PCARD_GUID32 sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-PCARD_XSETT sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-PYREF sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-PY_AMOUNT sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-PY_CURR sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-PY_PRIO sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-BITREF32 sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-PY_GROUP sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-CCARD_ID sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-CCINS sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-CCNUM sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-DATAB sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-DATBI sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-CCNAME sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-CGUID sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-ENCTP sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-AUNUM sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-AUTRA sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-AUDAT sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-AUTIM sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-AUTWR sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-CCWAE sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-MERCH sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-EXPDT sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-EXPTM sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-EXTMP sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-AUTMP sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-AUCID sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-AVREF sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-EMADR sy-vline
WA_FKKBIX_RATING_BIT_PY_STR-EMCRD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.