ABAP Select data from SAP table FKKBIEDR_PRNT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKBIEDR_PRNT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKBIEDR_PRNT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKKBIEDR_PRNT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKKBIEDR_PRNT TYPE STANDARD TABLE OF FKKBIEDR_PRNT,
      WA_FKKBIEDR_PRNT TYPE FKKBIEDR_PRNT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKKBIEDR_PRNT> TYPE FKKBIEDR_PRNT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKKBIEDR_PRNT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKKBIEDR_PRNT
  INTO TABLE IT_FKKBIEDR_PRNT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKKBIEDR_PRNT
*  INTO TABLE @DATA(IT_FKKBIEDR_PRNT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKKBIEDR_PRNT INDEX 1 INTO DATA(WA_FKKBIEDR_PRNT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKKBIEDR_PRNT ASSIGNING <FKKBIEDR_PRNT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKBIEDR_PRNT>-BILLDOCNO = 1.
<FKKBIEDR_PRNT>-MANDT = 1.
<FKKBIEDR_PRNT>-LOADPERIOD = 1.
<FKKBIEDR_PRNT>-BILLACCOUNT = 1.
<FKKBIEDR_PRNT>-LOADTIME = 1.
ENDLOOP.

LOOP AT IT_FKKBIEDR_PRNT INTO WA_FKKBIEDR_PRNT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKKBIEDR_PRNT-EDRUUID, sy-vline,
WA_FKKBIEDR_PRNT-EVENTTIME, sy-vline,
WA_FKKBIEDR_PRNT-EDRTYPE, sy-vline,
WA_FKKBIEDR_PRNT-EDRAMOUNT, sy-vline,
WA_FKKBIEDR_PRNT-EDRCURR, sy-vline,
WA_FKKBIEDR_PRNT-BILLINGOBJECT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKBIEDR_PRNT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKBIEDR_PRNT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKBIEDR_PRNT INTO WA_FKKBIEDR_PRNT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EMGPA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKBIEDR_PRNT-EMGPA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKBIEDR_PRNT-EMGPA.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKBIEDR_PRNT_STR,
BILLDOCNO TYPE STRING,
MANDT TYPE STRING,
LOADPERIOD TYPE STRING,
BILLACCOUNT TYPE STRING,
LOADTIME TYPE STRING,
EDRUUID TYPE STRING,
EVENTTIME TYPE STRING,
EDRTYPE TYPE STRING,
EDRAMOUNT TYPE STRING,
EDRCURR TYPE STRING,
BILLINGOBJECT TYPE STRING,
EDRCAT TYPE STRING,
EMISSCLASS TYPE STRING,
AXLECLASS TYPE STRING,
EMBVT TYPE STRING,
EMGPA TYPE STRING,
PCARD_GUID TYPE STRING,
PCARD_XSETT TYPE STRING,
PYREF TYPE STRING,
PY_AMOUNT TYPE STRING,
PY_CURR TYPE STRING,
PY_PRIO TYPE STRING,
PYMET TYPE STRING,
LOAD_DATE TYPE STRING,
LOAD_TIME TYPE STRING,
EVENT_DATE TYPE STRING,
EVENT_TIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKBIEDR_PRNT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKBIEDR_PRNT_STR-BILLDOCNO sy-vline
WA_FKKBIEDR_PRNT_STR-MANDT sy-vline
WA_FKKBIEDR_PRNT_STR-LOADPERIOD sy-vline
WA_FKKBIEDR_PRNT_STR-BILLACCOUNT sy-vline
WA_FKKBIEDR_PRNT_STR-LOADTIME sy-vline
WA_FKKBIEDR_PRNT_STR-EDRUUID sy-vline
WA_FKKBIEDR_PRNT_STR-EVENTTIME sy-vline
WA_FKKBIEDR_PRNT_STR-EDRTYPE sy-vline
WA_FKKBIEDR_PRNT_STR-EDRAMOUNT sy-vline
WA_FKKBIEDR_PRNT_STR-EDRCURR sy-vline
WA_FKKBIEDR_PRNT_STR-BILLINGOBJECT sy-vline
WA_FKKBIEDR_PRNT_STR-EDRCAT sy-vline
WA_FKKBIEDR_PRNT_STR-EMISSCLASS sy-vline
WA_FKKBIEDR_PRNT_STR-AXLECLASS sy-vline
WA_FKKBIEDR_PRNT_STR-EMBVT sy-vline
WA_FKKBIEDR_PRNT_STR-EMGPA sy-vline
WA_FKKBIEDR_PRNT_STR-PCARD_GUID sy-vline
WA_FKKBIEDR_PRNT_STR-PCARD_XSETT sy-vline
WA_FKKBIEDR_PRNT_STR-PYREF sy-vline
WA_FKKBIEDR_PRNT_STR-PY_AMOUNT sy-vline
WA_FKKBIEDR_PRNT_STR-PY_CURR sy-vline
WA_FKKBIEDR_PRNT_STR-PY_PRIO sy-vline
WA_FKKBIEDR_PRNT_STR-PYMET sy-vline
WA_FKKBIEDR_PRNT_STR-LOAD_DATE sy-vline
WA_FKKBIEDR_PRNT_STR-LOAD_TIME sy-vline
WA_FKKBIEDR_PRNT_STR-EVENT_DATE sy-vline
WA_FKKBIEDR_PRNT_STR-EVENT_TIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.