ABAP Select data from SAP table FKKBI_BWTRIG_DISP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKBI_BWTRIG_DISP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKBI_BWTRIG_DISP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKKBI_BWTRIG_DISP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKKBI_BWTRIG_DISP TYPE STANDARD TABLE OF FKKBI_BWTRIG_DISP,
      WA_FKKBI_BWTRIG_DISP TYPE FKKBI_BWTRIG_DISP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKKBI_BWTRIG_DISP> TYPE FKKBI_BWTRIG_DISP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKKBI_BWTRIG_DISP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKKBI_BWTRIG_DISP
  INTO TABLE IT_FKKBI_BWTRIG_DISP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKKBI_BWTRIG_DISP
*  INTO TABLE @DATA(IT_FKKBI_BWTRIG_DISP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKKBI_BWTRIG_DISP INDEX 1 INTO DATA(WA_FKKBI_BWTRIG_DISP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKKBI_BWTRIG_DISP ASSIGNING <FKKBI_BWTRIG_DISP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKBI_BWTRIG_DISP>-MANDT = 1.
<FKKBI_BWTRIG_DISP>-APPLK = 1.
<FKKBI_BWTRIG_DISP>-EDRCAT = 1.
<FKKBI_BWTRIG_DISP>-DATASOURCE = 1.
<FKKBI_BWTRIG_DISP>-LOADPERIOD = 1.
ENDLOOP.

LOOP AT IT_FKKBI_BWTRIG_DISP INTO WA_FKKBI_BWTRIG_DISP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKKBI_BWTRIG_DISP-BILLACCOUNT, sy-vline,
WA_FKKBI_BWTRIG_DISP-GPART, sy-vline,
WA_FKKBI_BWTRIG_DISP-VKONT, sy-vline,
WA_FKKBI_BWTRIG_DISP-VTREF, sy-vline,
WA_FKKBI_BWTRIG_DISP-LOADTIME, sy-vline,
WA_FKKBI_BWTRIG_DISP-BA_FROM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKBI_BWTRIG_DISP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKBI_BWTRIG_DISP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKBI_BWTRIG_DISP INTO WA_FKKBI_BWTRIG_DISP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKBI_BWTRIG_DISP-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKBI_BWTRIG_DISP-GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKBI_BWTRIG_DISP-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKBI_BWTRIG_DISP-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VTREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKBI_BWTRIG_DISP-VTREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKBI_BWTRIG_DISP-VTREF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKBI_BWTRIG_DISP_STR,
MANDT TYPE STRING,
APPLK TYPE STRING,
EDRCAT TYPE STRING,
DATASOURCE TYPE STRING,
LOADPERIOD TYPE STRING,
BILLACCOUNT TYPE STRING,
GPART TYPE STRING,
VKONT TYPE STRING,
VTREF TYPE STRING,
LOADTIME TYPE STRING,
BA_FROM TYPE STRING,
BA_TO TYPE STRING,
BW_INIT_STATUS TYPE STRING,
BILL_EXPAND TYPE STRING,
SIMULATE TYPE STRING,
SIMULATE_LOG TYPE STRING,
LOG_HANDLE TYPE STRING,
CRMODE TYPE STRING,
CRDATE TYPE STRING,
CRTIME TYPE STRING,
CRREQUNR TYPE STRING,
EXTRACT_TO TYPE STRING,
EXTRACTED_TO TYPE STRING,
LAST_BA TYPE STRING,
LAST_LOADTIME TYPE STRING,
REQUNR TYPE STRING,
BWTRIG_EXSTAT TYPE STRING,
EXDATE TYPE STRING,
EXTIME TYPE STRING,
EXDURA TYPE STRING,
CNT_BILLACC_EXTR TYPE STRING,
CNT_BILLACC_CANC TYPE STRING,
CNT_EDR_EXTR TYPE STRING,
CNT_DS_LINES TYPE STRING,
BILLACCTYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKBI_BWTRIG_DISP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKBI_BWTRIG_DISP_STR-MANDT sy-vline
WA_FKKBI_BWTRIG_DISP_STR-APPLK sy-vline
WA_FKKBI_BWTRIG_DISP_STR-EDRCAT sy-vline
WA_FKKBI_BWTRIG_DISP_STR-DATASOURCE sy-vline
WA_FKKBI_BWTRIG_DISP_STR-LOADPERIOD sy-vline
WA_FKKBI_BWTRIG_DISP_STR-BILLACCOUNT sy-vline
WA_FKKBI_BWTRIG_DISP_STR-GPART sy-vline
WA_FKKBI_BWTRIG_DISP_STR-VKONT sy-vline
WA_FKKBI_BWTRIG_DISP_STR-VTREF sy-vline
WA_FKKBI_BWTRIG_DISP_STR-LOADTIME sy-vline
WA_FKKBI_BWTRIG_DISP_STR-BA_FROM sy-vline
WA_FKKBI_BWTRIG_DISP_STR-BA_TO sy-vline
WA_FKKBI_BWTRIG_DISP_STR-BW_INIT_STATUS sy-vline
WA_FKKBI_BWTRIG_DISP_STR-BILL_EXPAND sy-vline
WA_FKKBI_BWTRIG_DISP_STR-SIMULATE sy-vline
WA_FKKBI_BWTRIG_DISP_STR-SIMULATE_LOG sy-vline
WA_FKKBI_BWTRIG_DISP_STR-LOG_HANDLE sy-vline
WA_FKKBI_BWTRIG_DISP_STR-CRMODE sy-vline
WA_FKKBI_BWTRIG_DISP_STR-CRDATE sy-vline
WA_FKKBI_BWTRIG_DISP_STR-CRTIME sy-vline
WA_FKKBI_BWTRIG_DISP_STR-CRREQUNR sy-vline
WA_FKKBI_BWTRIG_DISP_STR-EXTRACT_TO sy-vline
WA_FKKBI_BWTRIG_DISP_STR-EXTRACTED_TO sy-vline
WA_FKKBI_BWTRIG_DISP_STR-LAST_BA sy-vline
WA_FKKBI_BWTRIG_DISP_STR-LAST_LOADTIME sy-vline
WA_FKKBI_BWTRIG_DISP_STR-REQUNR sy-vline
WA_FKKBI_BWTRIG_DISP_STR-BWTRIG_EXSTAT sy-vline
WA_FKKBI_BWTRIG_DISP_STR-EXDATE sy-vline
WA_FKKBI_BWTRIG_DISP_STR-EXTIME sy-vline
WA_FKKBI_BWTRIG_DISP_STR-EXDURA sy-vline
WA_FKKBI_BWTRIG_DISP_STR-CNT_BILLACC_EXTR sy-vline
WA_FKKBI_BWTRIG_DISP_STR-CNT_BILLACC_CANC sy-vline
WA_FKKBI_BWTRIG_DISP_STR-CNT_EDR_EXTR sy-vline
WA_FKKBI_BWTRIG_DISP_STR-CNT_DS_LINES sy-vline
WA_FKKBI_BWTRIG_DISP_STR-BILLACCTYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.