ABAP Select data from SAP table FKK_VT_SEL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKK_VT_SEL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKK_VT_SEL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKK_VT_SEL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKK_VT_SEL TYPE STANDARD TABLE OF FKK_VT_SEL,
      WA_FKK_VT_SEL TYPE FKK_VT_SEL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKK_VT_SEL> TYPE FKK_VT_SEL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKK_VT_SEL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKK_VT_SEL
  INTO TABLE IT_FKK_VT_SEL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKK_VT_SEL
*  INTO TABLE @DATA(IT_FKK_VT_SEL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKK_VT_SEL INDEX 1 INTO DATA(WA_FKK_VT_SEL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKK_VT_SEL ASSIGNING <FKK_VT_SEL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKK_VT_SEL>-VTPOS = 1.
<FKK_VT_SEL>-VTKEY = 1.
<FKK_VT_SEL>-GPART = 1.
<FKK_VT_SEL>-LOEVM = 1.
<FKK_VT_SEL>-VTBEZ = 1.
ENDLOOP.

LOOP AT IT_FKK_VT_SEL INTO WA_FKK_VT_SEL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKK_VT_SEL-VTALT, sy-vline,
WA_FKK_VT_SEL-VTBEG, sy-vline,
WA_FKK_VT_SEL-VTEND, sy-vline,
WA_FKK_VT_SEL-BEGRU, sy-vline,
WA_FKK_VT_SEL-BUKRS, sy-vline,
WA_FKK_VT_SEL-BUKRS_I, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKK_VT_SEL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKK_VT_SEL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKK_VT_SEL INTO WA_FKK_VT_SEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VTKEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_VT_SEL-VTKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_VT_SEL-VTKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_VT_SEL-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_VT_SEL-GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VTALT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_VT_SEL-VTALT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_VT_SEL-VTALT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_VT_SEL-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_VT_SEL-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PPACC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_VT_SEL-PPACC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_VT_SEL-PPACC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_VT_SEL-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_VT_SEL-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEGMT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_VT_SEL-SEGMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_VT_SEL-SEGMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MAKEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_VT_SEL-MAKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_VT_SEL-MAKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SRVRP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_VT_SEL-SRVRP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_VT_SEL-SRVRP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VTKRF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_VT_SEL-VTKRF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_VT_SEL-VTKRF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKK_VT_SEL_STR,
VTPOS TYPE STRING,
VTKEY TYPE STRING,
GPART TYPE STRING,
LOEVM TYPE STRING,
VTBEZ TYPE STRING,
VTALT TYPE STRING,
VTBEG TYPE STRING,
VTEND TYPE STRING,
BEGRU TYPE STRING,
BUKRS TYPE STRING,
BUKRS_I TYPE STRING,
TZONE TYPE STRING,
VTCAT TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
VTITT TYPE STRING,
VKONT TYPE STRING,
PPACC TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
PRCTR TYPE STRING,
SEGMT TYPE STRING,
STDSP TYPE STRING,
GSBER TYPE STRING,
PRDNR TYPE STRING,
CYCLE TYPE STRING,
CYCLE_DAY TYPE STRING,
CYCLE_DATE TYPE STRING,
VALTO_PRE TYPE STRING,
VTTRG TYPE STRING,
MAKEY TYPE STRING,
MAPRD TYPE STRING,
SRVRP TYPE STRING,
PTSRL TYPE STRING,
VTCHR TYPE STRING,
VTKRF TYPE STRING,
VTBEG_LOCL TYPE STRING,
VTEND_LOCL TYPE STRING,
VALFR_LOCL TYPE STRING,
VALTO_LOCL TYPE STRING,
VBER1 TYPE STRING,
VBER2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKK_VT_SEL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKK_VT_SEL_STR-VTPOS sy-vline
WA_FKK_VT_SEL_STR-VTKEY sy-vline
WA_FKK_VT_SEL_STR-GPART sy-vline
WA_FKK_VT_SEL_STR-LOEVM sy-vline
WA_FKK_VT_SEL_STR-VTBEZ sy-vline
WA_FKK_VT_SEL_STR-VTALT sy-vline
WA_FKK_VT_SEL_STR-VTBEG sy-vline
WA_FKK_VT_SEL_STR-VTEND sy-vline
WA_FKK_VT_SEL_STR-BEGRU sy-vline
WA_FKK_VT_SEL_STR-BUKRS sy-vline
WA_FKK_VT_SEL_STR-BUKRS_I sy-vline
WA_FKK_VT_SEL_STR-TZONE sy-vline
WA_FKK_VT_SEL_STR-VTCAT sy-vline
WA_FKK_VT_SEL_STR-ERDAT sy-vline
WA_FKK_VT_SEL_STR-ERNAM sy-vline
WA_FKK_VT_SEL_STR-VALFR sy-vline
WA_FKK_VT_SEL_STR-VALTO sy-vline
WA_FKK_VT_SEL_STR-VTITT sy-vline
WA_FKK_VT_SEL_STR-VKONT sy-vline
WA_FKK_VT_SEL_STR-PPACC sy-vline
WA_FKK_VT_SEL_STR-VKORG sy-vline
WA_FKK_VT_SEL_STR-VTWEG sy-vline
WA_FKK_VT_SEL_STR-SPART sy-vline
WA_FKK_VT_SEL_STR-PRCTR sy-vline
WA_FKK_VT_SEL_STR-SEGMT sy-vline
WA_FKK_VT_SEL_STR-STDSP sy-vline
WA_FKK_VT_SEL_STR-GSBER sy-vline
WA_FKK_VT_SEL_STR-PRDNR sy-vline
WA_FKK_VT_SEL_STR-CYCLE sy-vline
WA_FKK_VT_SEL_STR-CYCLE_DAY sy-vline
WA_FKK_VT_SEL_STR-CYCLE_DATE sy-vline
WA_FKK_VT_SEL_STR-VALTO_PRE sy-vline
WA_FKK_VT_SEL_STR-VTTRG sy-vline
WA_FKK_VT_SEL_STR-MAKEY sy-vline
WA_FKK_VT_SEL_STR-MAPRD sy-vline
WA_FKK_VT_SEL_STR-SRVRP sy-vline
WA_FKK_VT_SEL_STR-PTSRL sy-vline
WA_FKK_VT_SEL_STR-VTCHR sy-vline
WA_FKK_VT_SEL_STR-VTKRF sy-vline
WA_FKK_VT_SEL_STR-VTBEG_LOCL sy-vline
WA_FKK_VT_SEL_STR-VTEND_LOCL sy-vline
WA_FKK_VT_SEL_STR-VALFR_LOCL sy-vline
WA_FKK_VT_SEL_STR-VALTO_LOCL sy-vline
WA_FKK_VT_SEL_STR-VBER1 sy-vline
WA_FKK_VT_SEL_STR-VBER2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.