ABAP Select data from SAP table FKK_VT_CONTROL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKK_VT_CONTROL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKK_VT_CONTROL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKK_VT_CONTROL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKK_VT_CONTROL TYPE STANDARD TABLE OF FKK_VT_CONTROL,
      WA_FKK_VT_CONTROL TYPE FKK_VT_CONTROL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKK_VT_CONTROL> TYPE FKK_VT_CONTROL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKK_VT_CONTROL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKK_VT_CONTROL
  INTO TABLE IT_FKK_VT_CONTROL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKK_VT_CONTROL
*  INTO TABLE @DATA(IT_FKK_VT_CONTROL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKK_VT_CONTROL INDEX 1 INTO DATA(WA_FKK_VT_CONTROL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKK_VT_CONTROL ASSIGNING <FKK_VT_CONTROL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKK_VT_CONTROL>-AKTDB = 1.
<FKK_VT_CONTROL>-AKTYP = 1.
<FKK_VT_CONTROL>-XCHNG = 1.
<FKK_VT_CONTROL>-NRRNG = 1.
<FKK_VT_CONTROL>-XNREX = 1.
ENDLOOP.

LOOP AT IT_FKK_VT_CONTROL INTO WA_FKK_VT_CONTROL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKK_VT_CONTROL-VALDT, sy-vline,
WA_FKK_VT_CONTROL-XENQUEUE, sy-vline,
WA_FKK_VT_CONTROL-XUPDTASK, sy-vline,
WA_FKK_VT_CONTROL-XSAVED, sy-vline,
WA_FKK_VT_CONTROL-XTEST, sy-vline,
WA_FKK_VT_CONTROL-XDINP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKK_VT_CONTROL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKK_VT_CONTROL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKK_VT_CONTROL INTO WA_FKK_VT_CONTROL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKK_VT_CONTROL_STR,
AKTDB TYPE STRING,
AKTYP TYPE STRING,
XCHNG TYPE STRING,
NRRNG TYPE STRING,
XNREX TYPE STRING,
VALDT TYPE STRING,
XENQUEUE TYPE STRING,
XUPDTASK TYPE STRING,
XSAVED TYPE STRING,
XTEST TYPE STRING,
XDINP TYPE STRING,
RUN_TIMESTAMP TYPE STRING,
XCHDOC TYPE STRING,
XLOCKSREAD TYPE STRING,
VALID_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKK_VT_CONTROL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKK_VT_CONTROL_STR-AKTDB sy-vline
WA_FKK_VT_CONTROL_STR-AKTYP sy-vline
WA_FKK_VT_CONTROL_STR-XCHNG sy-vline
WA_FKK_VT_CONTROL_STR-NRRNG sy-vline
WA_FKK_VT_CONTROL_STR-XNREX sy-vline
WA_FKK_VT_CONTROL_STR-VALDT sy-vline
WA_FKK_VT_CONTROL_STR-XENQUEUE sy-vline
WA_FKK_VT_CONTROL_STR-XUPDTASK sy-vline
WA_FKK_VT_CONTROL_STR-XSAVED sy-vline
WA_FKK_VT_CONTROL_STR-XTEST sy-vline
WA_FKK_VT_CONTROL_STR-XDINP sy-vline
WA_FKK_VT_CONTROL_STR-RUN_TIMESTAMP sy-vline
WA_FKK_VT_CONTROL_STR-XCHDOC sy-vline
WA_FKK_VT_CONTROL_STR-XLOCKSREAD sy-vline
WA_FKK_VT_CONTROL_STR-VALID_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.