ABAP Select data from SAP table FKK_MAD_FILTER_SCR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKK_MAD_FILTER_SCR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKK_MAD_FILTER_SCR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKK_MAD_FILTER_SCR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKK_MAD_FILTER_SCR TYPE STANDARD TABLE OF FKK_MAD_FILTER_SCR,
      WA_FKK_MAD_FILTER_SCR TYPE FKK_MAD_FILTER_SCR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKK_MAD_FILTER_SCR> TYPE FKK_MAD_FILTER_SCR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKK_MAD_FILTER_SCR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKK_MAD_FILTER_SCR
  INTO TABLE IT_FKK_MAD_FILTER_SCR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKK_MAD_FILTER_SCR
*  INTO TABLE @DATA(IT_FKK_MAD_FILTER_SCR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKK_MAD_FILTER_SCR INDEX 1 INTO DATA(WA_FKK_MAD_FILTER_SCR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKK_MAD_FILTER_SCR ASSIGNING <FKK_MAD_FILTER_SCR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKK_MAD_FILTER_SCR>-SEL_TYPE = 1.
<FKK_MAD_FILTER_SCR>-SEL_GPART = 1.
<FKK_MAD_FILTER_SCR>-SEL_NAME = 1.
<FKK_MAD_FILTER_SCR>-TEXT = 1.
<FKK_MAD_FILTER_SCR>-SEL_NAME_OLD = 1.
ENDLOOP.

LOOP AT IT_FKK_MAD_FILTER_SCR INTO WA_FKK_MAD_FILTER_SCR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKK_MAD_FILTER_SCR-TEXT_OLD, sy-vline,
WA_FKK_MAD_FILTER_SCR-UNAME, sy-vline,
WA_FKK_MAD_FILTER_SCR-DATUM, sy-vline,
WA_FKK_MAD_FILTER_SCR-UZEIT, sy-vline,
WA_FKK_MAD_FILTER_SCR-MTUSR_NAME, sy-vline,
ENDLOOP. *Add any further fields from structure WA_FKK_MAD_FILTER_SCR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKK_MAD_FILTER_SCR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKK_MAD_FILTER_SCR INTO WA_FKK_MAD_FILTER_SCR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SEL_GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_MAD_FILTER_SCR-SEL_GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_MAD_FILTER_SCR-SEL_GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEL_NAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_MAD_FILTER_SCR-SEL_NAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_MAD_FILTER_SCR-SEL_NAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEL_NAME_OLD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_MAD_FILTER_SCR-SEL_NAME_OLD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_MAD_FILTER_SCR-SEL_NAME_OLD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKK_MAD_FILTER_SCR_STR,
SEL_TYPE TYPE STRING,
SEL_GPART TYPE STRING,
SEL_NAME TYPE STRING,
TEXT TYPE STRING,
SEL_NAME_OLD TYPE STRING,
TEXT_OLD TYPE STRING,
UNAME TYPE STRING,
DATUM TYPE STRING,
UZEIT TYPE STRING,
MTUSR_NAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKK_MAD_FILTER_SCR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKK_MAD_FILTER_SCR_STR-SEL_TYPE sy-vline
WA_FKK_MAD_FILTER_SCR_STR-SEL_GPART sy-vline
WA_FKK_MAD_FILTER_SCR_STR-SEL_NAME sy-vline
WA_FKK_MAD_FILTER_SCR_STR-TEXT sy-vline
WA_FKK_MAD_FILTER_SCR_STR-SEL_NAME_OLD sy-vline
WA_FKK_MAD_FILTER_SCR_STR-TEXT_OLD sy-vline
WA_FKK_MAD_FILTER_SCR_STR-UNAME sy-vline
WA_FKK_MAD_FILTER_SCR_STR-DATUM sy-vline
WA_FKK_MAD_FILTER_SCR_STR-UZEIT sy-vline
WA_FKK_MAD_FILTER_SCR_STR-MTUSR_NAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.