ABAP Select data from SAP table FKK_CREDITITEM_ODATA_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKK_CREDITITEM_ODATA_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKK_CREDITITEM_ODATA_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKK_CREDITITEM_ODATA_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKK_CREDITITEM_ODATA_DATA TYPE STANDARD TABLE OF FKK_CREDITITEM_ODATA_DATA,
      WA_FKK_CREDITITEM_ODATA_DATA TYPE FKK_CREDITITEM_ODATA_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKK_CREDITITEM_ODATA_DATA> TYPE FKK_CREDITITEM_ODATA_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKK_CREDITITEM_ODATA_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKK_CREDITITEM_ODATA_DATA
  INTO TABLE IT_FKK_CREDITITEM_ODATA_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKK_CREDITITEM_ODATA_DATA
*  INTO TABLE @DATA(IT_FKK_CREDITITEM_ODATA_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKK_CREDITITEM_ODATA_DATA INDEX 1 INTO DATA(WA_FKK_CREDITITEM_ODATA_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKK_CREDITITEM_ODATA_DATA ASSIGNING <FKK_CREDITITEM_ODATA_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKK_CREDITITEM_ODATA_DATA>-ODATA_KEY = 1.
<FKK_CREDITITEM_ODATA_DATA>-BETRW = 1.
<FKK_CREDITITEM_ODATA_DATA>-WAERS = 1.
<FKK_CREDITITEM_ODATA_DATA>-BUKRS = 1.
<FKK_CREDITITEM_ODATA_DATA>-SEGMENT = 1.
ENDLOOP.

LOOP AT IT_FKK_CREDITITEM_ODATA_DATA INTO WA_FKK_CREDITITEM_ODATA_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKK_CREDITITEM_ODATA_DATA-SPART, sy-vline,
WA_FKK_CREDITITEM_ODATA_DATA-GSBER, sy-vline,
WA_FKK_CREDITITEM_ODATA_DATA-GPART, sy-vline,
WA_FKK_CREDITITEM_ODATA_DATA-POSTALCODE, sy-vline,
WA_FKK_CREDITITEM_ODATA_DATA-VKONT, sy-vline,
WA_FKK_CREDITITEM_ODATA_DATA-VKTYP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKK_CREDITITEM_ODATA_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKK_CREDITITEM_ODATA_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKK_CREDITITEM_ODATA_DATA INTO WA_FKK_CREDITITEM_ODATA_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SEGMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_CREDITITEM_ODATA_DATA-SEGMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_CREDITITEM_ODATA_DATA-SEGMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_CREDITITEM_ODATA_DATA-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_CREDITITEM_ODATA_DATA-GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_CREDITITEM_ODATA_DATA-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_CREDITITEM_ODATA_DATA-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VTREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKK_CREDITITEM_ODATA_DATA-VTREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKK_CREDITITEM_ODATA_DATA-VTREF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKK_CREDITITEM_ODATA_DATA_STR,
ODATA_KEY TYPE STRING,
BETRW TYPE STRING,
WAERS TYPE STRING,
BUKRS TYPE STRING,
SEGMENT TYPE STRING,
SPART TYPE STRING,
GSBER TYPE STRING,
GPART TYPE STRING,
POSTALCODE TYPE STRING,
VKONT TYPE STRING,
VKTYP TYPE STRING,
KOFIZ TYPE STRING,
BLART TYPE STRING,
HVORG TYPE STRING,
TVORG TYPE STRING,
STAKZ TYPE STRING,
FAEDN TYPE STRING,
BEGRU TYPE STRING,
ITEMNUMBER TYPE STRING,
PERTYPE TYPE STRING,
PERNUMBER TYPE STRING,
PERFROM TYPE STRING,
PERTO TYPE STRING,
APPSTATE TYPE STRING,
TEXT TYPE STRING,
FAEDN_CODE TYPE STRING,
VTREF TYPE STRING,
SUBAP TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKK_CREDITITEM_ODATA_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-ODATA_KEY sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-BETRW sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-WAERS sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-BUKRS sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-SEGMENT sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-SPART sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-GSBER sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-GPART sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-POSTALCODE sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-VKONT sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-VKTYP sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-KOFIZ sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-BLART sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-HVORG sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-TVORG sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-STAKZ sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-FAEDN sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-BEGRU sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-ITEMNUMBER sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-PERTYPE sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-PERNUMBER sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-PERFROM sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-PERTO sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-APPSTATE sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-TEXT sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-FAEDN_CODE sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-VTREF sy-vline
WA_FKK_CREDITITEM_ODATA_DATA_STR-SUBAP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.