ABAP Select data from SAP table FKC_MIG_FKK_SEC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKC_MIG_FKK_SEC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKC_MIG_FKK_SEC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKC_MIG_FKK_SEC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKC_MIG_FKK_SEC TYPE STANDARD TABLE OF FKC_MIG_FKK_SEC,
      WA_FKC_MIG_FKK_SEC TYPE FKC_MIG_FKK_SEC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKC_MIG_FKK_SEC> TYPE FKC_MIG_FKK_SEC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKC_MIG_FKK_SEC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKC_MIG_FKK_SEC
  INTO TABLE IT_FKC_MIG_FKK_SEC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKC_MIG_FKK_SEC
*  INTO TABLE @DATA(IT_FKC_MIG_FKK_SEC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKC_MIG_FKK_SEC INDEX 1 INTO DATA(WA_FKC_MIG_FKK_SEC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKC_MIG_FKK_SEC ASSIGNING <FKC_MIG_FKK_SEC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKC_MIG_FKK_SEC>-SENDER_TECHNICAL_ID = 1.
<FKC_MIG_FKK_SEC>-SECURITY = 1.
<FKC_MIG_FKK_SEC>-VKONT = 1.
<FKC_MIG_FKK_SEC>-REASON = 1.
<FKC_MIG_FKK_SEC>-REQUEST = 1.
ENDLOOP.

LOOP AT IT_FKC_MIG_FKK_SEC INTO WA_FKC_MIG_FKK_SEC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKC_MIG_FKK_SEC-WAERS, sy-vline,
WA_FKC_MIG_FKK_SEC-SEC_START, sy-vline,
WA_FKC_MIG_FKK_SEC-SEC_RETURN, sy-vline,
WA_FKC_MIG_FKK_SEC-IKEY, sy-vline,
WA_FKC_MIG_FKK_SEC-EXT_REF_NO, sy-vline,
WA_FKC_MIG_FKK_SEC-VTREF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKC_MIG_FKK_SEC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKC_MIG_FKK_SEC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKC_MIG_FKK_SEC INTO WA_FKC_MIG_FKK_SEC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SECURITY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKC_MIG_FKK_SEC-SECURITY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKC_MIG_FKK_SEC-SECURITY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKC_MIG_FKK_SEC-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKC_MIG_FKK_SEC-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VTREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKC_MIG_FKK_SEC-VTREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKC_MIG_FKK_SEC-VTREF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKC_MIG_FKK_SEC_STR,
SENDER_TECHNICAL_ID TYPE STRING,
SECURITY TYPE STRING,
VKONT TYPE STRING,
REASON TYPE STRING,
REQUEST TYPE STRING,
WAERS TYPE STRING,
SEC_START TYPE STRING,
SEC_RETURN TYPE STRING,
IKEY TYPE STRING,
EXT_REF_NO TYPE STRING,
VTREF TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKC_MIG_FKK_SEC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKC_MIG_FKK_SEC_STR-SENDER_TECHNICAL_ID sy-vline
WA_FKC_MIG_FKK_SEC_STR-SECURITY sy-vline
WA_FKC_MIG_FKK_SEC_STR-VKONT sy-vline
WA_FKC_MIG_FKK_SEC_STR-REASON sy-vline
WA_FKC_MIG_FKK_SEC_STR-REQUEST sy-vline
WA_FKC_MIG_FKK_SEC_STR-WAERS sy-vline
WA_FKC_MIG_FKK_SEC_STR-SEC_START sy-vline
WA_FKC_MIG_FKK_SEC_STR-SEC_RETURN sy-vline
WA_FKC_MIG_FKK_SEC_STR-IKEY sy-vline
WA_FKC_MIG_FKK_SEC_STR-EXT_REF_NO sy-vline
WA_FKC_MIG_FKK_SEC_STR-VTREF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.