ABAP Select data from SAP table FITV_S_TA_PERS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FITV_S_TA_PERS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FITV_S_TA_PERS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FITV_S_TA_PERS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FITV_S_TA_PERS TYPE STANDARD TABLE OF FITV_S_TA_PERS,
      WA_FITV_S_TA_PERS TYPE FITV_S_TA_PERS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FITV_S_TA_PERS> TYPE FITV_S_TA_PERS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FITV_S_TA_PERS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FITV_S_TA_PERS
  INTO TABLE IT_FITV_S_TA_PERS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FITV_S_TA_PERS
*  INTO TABLE @DATA(IT_FITV_S_TA_PERS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FITV_S_TA_PERS INDEX 1 INTO DATA(WA_FITV_S_TA_PERS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FITV_S_TA_PERS ASSIGNING <FITV_S_TA_PERS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FITV_S_TA_PERS>-APPR_OBJ = 1.
<FITV_S_TA_PERS>-KOKRS = 1.
<FITV_S_TA_PERS>-KOSTL_SET = 1.
<FITV_S_TA_PERS>-KOSTL_SETX = 1.
<FITV_S_TA_PERS>-KOSTL_TO = 1.
ENDLOOP.

LOOP AT IT_FITV_S_TA_PERS INTO WA_FITV_S_TA_PERS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FITV_S_TA_PERS-KOSTL, sy-vline,
WA_FITV_S_TA_PERS-SELTYPE, sy-vline,
WA_FITV_S_TA_PERS-SEL_HRORG, sy-vline,
WA_FITV_S_TA_PERS-SEL_KONTOBJ, sy-vline,
WA_FITV_S_TA_PERS-SEL_STMOBJ, sy-vline,
WA_FITV_S_TA_PERS-SEL_PROFILE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FITV_S_TA_PERS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FITV_S_TA_PERS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FITV_S_TA_PERS INTO WA_FITV_S_TA_PERS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KOSTL_TO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FITV_S_TA_PERS-KOSTL_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FITV_S_TA_PERS-KOSTL_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FITV_S_TA_PERS-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FITV_S_TA_PERS-KOSTL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FITV_S_TA_PERS_STR,
APPR_OBJ TYPE STRING,
KOKRS TYPE STRING,
KOSTL_SET TYPE STRING,
KOSTL_SETX TYPE STRING,
KOSTL_TO TYPE STRING,
KOSTL TYPE STRING,
SELTYPE TYPE STRING,
SEL_HRORG TYPE STRING,
SEL_KONTOBJ TYPE STRING,
SEL_STMOBJ TYPE STRING,
SEL_PROFILE TYPE STRING,
SORT_BY TYPE STRING,
VIEWGR TYPE STRING,
VIEWID TYPE STRING,
DESIGN TYPE STRING,END OF T_EKKO_STR. DATA: WA_FITV_S_TA_PERS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FITV_S_TA_PERS_STR-APPR_OBJ sy-vline
WA_FITV_S_TA_PERS_STR-KOKRS sy-vline
WA_FITV_S_TA_PERS_STR-KOSTL_SET sy-vline
WA_FITV_S_TA_PERS_STR-KOSTL_SETX sy-vline
WA_FITV_S_TA_PERS_STR-KOSTL_TO sy-vline
WA_FITV_S_TA_PERS_STR-KOSTL sy-vline
WA_FITV_S_TA_PERS_STR-SELTYPE sy-vline
WA_FITV_S_TA_PERS_STR-SEL_HRORG sy-vline
WA_FITV_S_TA_PERS_STR-SEL_KONTOBJ sy-vline
WA_FITV_S_TA_PERS_STR-SEL_STMOBJ sy-vline
WA_FITV_S_TA_PERS_STR-SEL_PROFILE sy-vline
WA_FITV_S_TA_PERS_STR-SORT_BY sy-vline
WA_FITV_S_TA_PERS_STR-VIEWGR sy-vline
WA_FITV_S_TA_PERS_STR-VIEWID sy-vline
WA_FITV_S_TA_PERS_STR-DESIGN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.