ABAP Select data from SAP table FIS_FSV_DATA_SELECT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FIS_FSV_DATA_SELECT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FIS_FSV_DATA_SELECT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FIS_FSV_DATA_SELECT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FIS_FSV_DATA_SELECT TYPE STANDARD TABLE OF FIS_FSV_DATA_SELECT,
      WA_FIS_FSV_DATA_SELECT TYPE FIS_FSV_DATA_SELECT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FIS_FSV_DATA_SELECT> TYPE FIS_FSV_DATA_SELECT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FIS_FSV_DATA_SELECT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FIS_FSV_DATA_SELECT
  INTO TABLE IT_FIS_FSV_DATA_SELECT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FIS_FSV_DATA_SELECT
*  INTO TABLE @DATA(IT_FIS_FSV_DATA_SELECT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FIS_FSV_DATA_SELECT INDEX 1 INTO DATA(WA_FIS_FSV_DATA_SELECT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FIS_FSV_DATA_SELECT ASSIGNING <FIS_FSV_DATA_SELECT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FIS_FSV_DATA_SELECT>-CHANGID = 1.
<FIS_FSV_DATA_SELECT>-PARENT = 1.
<FIS_FSV_DATA_SELECT>-ID = 1.
<FIS_FSV_DATA_SELECT>-ERGSL = 1.
<FIS_FSV_DATA_SELECT>-RLDNR = 1.
ENDLOOP.

LOOP AT IT_FIS_FSV_DATA_SELECT INTO WA_FIS_FSV_DATA_SELECT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FIS_FSV_DATA_SELECT-RRCTY, sy-vline,
WA_FIS_FSV_DATA_SELECT-RVERS, sy-vline,
WA_FIS_FSV_DATA_SELECT-CURTP, sy-vline,
WA_FIS_FSV_DATA_SELECT-KTOPL, sy-vline,
WA_FIS_FSV_DATA_SELECT-RACCT, sy-vline,
WA_FIS_FSV_DATA_SELECT-KKTPL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FIS_FSV_DATA_SELECT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FIS_FSV_DATA_SELECT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FIS_FSV_DATA_SELECT INTO WA_FIS_FSV_DATA_SELECT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIS_FSV_DATA_SELECT-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIS_FSV_DATA_SELECT-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIS_FSV_DATA_SELECT-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIS_FSV_DATA_SELECT-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RACCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIS_FSV_DATA_SELECT-RACCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIS_FSV_DATA_SELECT-RACCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILKT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIS_FSV_DATA_SELECT-BILKT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIS_FSV_DATA_SELECT-BILKT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ALTKT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIS_FSV_DATA_SELECT-ALTKT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIS_FSV_DATA_SELECT-ALTKT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEGMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIS_FSV_DATA_SELECT-SEGMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIS_FSV_DATA_SELECT-SEGMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIS_FSV_DATA_SELECT-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIS_FSV_DATA_SELECT-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FIS_FSV_DATA_SELECT-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIS_FSV_DATA_SELECT-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field SALDO CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FIS_FSV_DATA_SELECT-SALDO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIS_FSV_DATA_SELECT-SALDO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FIS_FSV_DATA_SELECT_STR,
CHANGID TYPE STRING,
PARENT TYPE STRING,
ID TYPE STRING,
ERGSL TYPE STRING,
RLDNR TYPE STRING,
RRCTY TYPE STRING,
RVERS TYPE STRING,
CURTP TYPE STRING,
KTOPL TYPE STRING,
RACCT TYPE STRING,
KKTPL TYPE STRING,
BILKT TYPE STRING,
KTOP2 TYPE STRING,
ALTKT TYPE STRING,
RBUKRS TYPE STRING,
INCRMNT TYPE STRING,
RBUSA TYPE STRING,
RFAREA TYPE STRING,
SEGMENT TYPE STRING,
KOKRS TYPE STRING,
PRCTR TYPE STRING,
HBKID TYPE STRING,
HKTID TYPE STRING,
ACDOC_EEW_DUMMY TYPE STRING,
DUMMY_INCL_EEW_COBL TYPE STRING,
PLUMI TYPE STRING,
WAERS TYPE STRING,
PERIOD_SIGN TYPE STRING,
RYEAR TYPE STRING,
POPER TYPE STRING,
SALDO TYPE STRING,END OF T_EKKO_STR. DATA: WA_FIS_FSV_DATA_SELECT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FIS_FSV_DATA_SELECT_STR-CHANGID sy-vline
WA_FIS_FSV_DATA_SELECT_STR-PARENT sy-vline
WA_FIS_FSV_DATA_SELECT_STR-ID sy-vline
WA_FIS_FSV_DATA_SELECT_STR-ERGSL sy-vline
WA_FIS_FSV_DATA_SELECT_STR-RLDNR sy-vline
WA_FIS_FSV_DATA_SELECT_STR-RRCTY sy-vline
WA_FIS_FSV_DATA_SELECT_STR-RVERS sy-vline
WA_FIS_FSV_DATA_SELECT_STR-CURTP sy-vline
WA_FIS_FSV_DATA_SELECT_STR-KTOPL sy-vline
WA_FIS_FSV_DATA_SELECT_STR-RACCT sy-vline
WA_FIS_FSV_DATA_SELECT_STR-KKTPL sy-vline
WA_FIS_FSV_DATA_SELECT_STR-BILKT sy-vline
WA_FIS_FSV_DATA_SELECT_STR-KTOP2 sy-vline
WA_FIS_FSV_DATA_SELECT_STR-ALTKT sy-vline
WA_FIS_FSV_DATA_SELECT_STR-RBUKRS sy-vline
WA_FIS_FSV_DATA_SELECT_STR-INCRMNT sy-vline
WA_FIS_FSV_DATA_SELECT_STR-RBUSA sy-vline
WA_FIS_FSV_DATA_SELECT_STR-RFAREA sy-vline
WA_FIS_FSV_DATA_SELECT_STR-SEGMENT sy-vline
WA_FIS_FSV_DATA_SELECT_STR-KOKRS sy-vline
WA_FIS_FSV_DATA_SELECT_STR-PRCTR sy-vline
WA_FIS_FSV_DATA_SELECT_STR-HBKID sy-vline
WA_FIS_FSV_DATA_SELECT_STR-HKTID sy-vline
WA_FIS_FSV_DATA_SELECT_STR-ACDOC_EEW_DUMMY sy-vline
WA_FIS_FSV_DATA_SELECT_STR-DUMMY_INCL_EEW_COBL sy-vline
WA_FIS_FSV_DATA_SELECT_STR-PLUMI sy-vline
WA_FIS_FSV_DATA_SELECT_STR-WAERS sy-vline
WA_FIS_FSV_DATA_SELECT_STR-PERIOD_SIGN sy-vline
WA_FIS_FSV_DATA_SELECT_STR-RYEAR sy-vline
WA_FIS_FSV_DATA_SELECT_STR-POPER sy-vline
WA_FIS_FSV_DATA_SELECT_STR-SALDO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.