ABAP Select data from SAP table FIS_CF_FC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FIS_CF_FC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FIS_CF_FC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FIS_CF_FC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FIS_CF_FC TYPE STANDARD TABLE OF FIS_CF_FC,
      WA_FIS_CF_FC TYPE FIS_CF_FC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FIS_CF_FC> TYPE FIS_CF_FC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FIS_CF_FC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FIS_CF_FC
  INTO TABLE IT_FIS_CF_FC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FIS_CF_FC
*  INTO TABLE @DATA(IT_FIS_CF_FC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FIS_CF_FC INDEX 1 INTO DATA(WA_FIS_CF_FC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FIS_CF_FC ASSIGNING <FIS_CF_FC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FIS_CF_FC>-MANDT = 1.
<FIS_CF_FC>-APPLCLASS = 1.
<FIS_CF_FC>-SUBCLASS = 1.
<FIS_CF_FC>-TABNAME = 1.
<FIS_CF_FC>-FORM = 1.
ENDLOOP.

LOOP AT IT_FIS_CF_FC INTO WA_FIS_CF_FC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FIS_CF_FC-SUBNR, sy-vline,
WA_FIS_CF_FC-ELNR1, sy-vline,
WA_FIS_CF_FC-ELNR2, sy-vline,
WA_FIS_CF_FC-PRART, sy-vline,
WA_FIS_CF_FC-FROW, sy-vline,
WA_FIS_CF_FC-FCOLUMN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FIS_CF_FC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FIS_CF_FC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FIS_CF_FC INTO WA_FIS_CF_FC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FIS_CF_FC_STR,
MANDT TYPE STRING,
APPLCLASS TYPE STRING,
SUBCLASS TYPE STRING,
TABNAME TYPE STRING,
FORM TYPE STRING,
SUBNR TYPE STRING,
ELNR1 TYPE STRING,
ELNR2 TYPE STRING,
PRART TYPE STRING,
FROW TYPE STRING,
FCOLUMN TYPE STRING,
TXTKZ TYPE STRING,
TXTMT TYPE STRING,
TXTLG TYPE STRING,
FIELD TYPE STRING,
SNR TYPE STRING,
SIGN TYPE STRING,
OPT TYPE STRING,
LOW TYPE STRING,
HIGH TYPE STRING,
POINTER TYPE STRING,
LFDNR TYPE STRING,
FORMULA_Z TYPE STRING,
ELTYP TYPE STRING,
SUBNR_1 TYPE STRING,
ELNR2_1 TYPE STRING,
POINTER_A TYPE STRING,
LFDNR_1 TYPE STRING,
FORMULA_A TYPE STRING,
ELTYP_1 TYPE STRING,
FMLTP TYPE STRING,
FMLTP_1 TYPE STRING,
FLENGTH TYPE STRING,
TEXTA TYPE STRING,
LRIGHT TYPE STRING,
ROUND TYPE STRING,
DECIM TYPE STRING,
NOZERO TYPE STRING,
VZUK TYPE STRING,
INTENS TYPE STRING,
FLEX TYPE STRING,
PATTER TYPE STRING,
SFTCH TYPE STRING,
SFTCT TYPE STRING,
PRGRP TYPE STRING,
COLOR TYPE STRING,
FPAGE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FIS_CF_FC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FIS_CF_FC_STR-MANDT sy-vline
WA_FIS_CF_FC_STR-APPLCLASS sy-vline
WA_FIS_CF_FC_STR-SUBCLASS sy-vline
WA_FIS_CF_FC_STR-TABNAME sy-vline
WA_FIS_CF_FC_STR-FORM sy-vline
WA_FIS_CF_FC_STR-SUBNR sy-vline
WA_FIS_CF_FC_STR-ELNR1 sy-vline
WA_FIS_CF_FC_STR-ELNR2 sy-vline
WA_FIS_CF_FC_STR-PRART sy-vline
WA_FIS_CF_FC_STR-FROW sy-vline
WA_FIS_CF_FC_STR-FCOLUMN sy-vline
WA_FIS_CF_FC_STR-TXTKZ sy-vline
WA_FIS_CF_FC_STR-TXTMT sy-vline
WA_FIS_CF_FC_STR-TXTLG sy-vline
WA_FIS_CF_FC_STR-FIELD sy-vline
WA_FIS_CF_FC_STR-SNR sy-vline
WA_FIS_CF_FC_STR-SIGN sy-vline
WA_FIS_CF_FC_STR-OPT sy-vline
WA_FIS_CF_FC_STR-LOW sy-vline
WA_FIS_CF_FC_STR-HIGH sy-vline
WA_FIS_CF_FC_STR-POINTER sy-vline
WA_FIS_CF_FC_STR-LFDNR sy-vline
WA_FIS_CF_FC_STR-FORMULA_Z sy-vline
WA_FIS_CF_FC_STR-ELTYP sy-vline
WA_FIS_CF_FC_STR-SUBNR_1 sy-vline
WA_FIS_CF_FC_STR-ELNR2_1 sy-vline
WA_FIS_CF_FC_STR-POINTER_A sy-vline
WA_FIS_CF_FC_STR-LFDNR_1 sy-vline
WA_FIS_CF_FC_STR-FORMULA_A sy-vline
WA_FIS_CF_FC_STR-ELTYP_1 sy-vline
WA_FIS_CF_FC_STR-FMLTP sy-vline
WA_FIS_CF_FC_STR-FMLTP_1 sy-vline
WA_FIS_CF_FC_STR-FLENGTH sy-vline
WA_FIS_CF_FC_STR-TEXTA sy-vline
WA_FIS_CF_FC_STR-LRIGHT sy-vline
WA_FIS_CF_FC_STR-ROUND sy-vline
WA_FIS_CF_FC_STR-DECIM sy-vline
WA_FIS_CF_FC_STR-NOZERO sy-vline
WA_FIS_CF_FC_STR-VZUK sy-vline
WA_FIS_CF_FC_STR-INTENS sy-vline
WA_FIS_CF_FC_STR-FLEX sy-vline
WA_FIS_CF_FC_STR-PATTER sy-vline
WA_FIS_CF_FC_STR-SFTCH sy-vline
WA_FIS_CF_FC_STR-SFTCT sy-vline
WA_FIS_CF_FC_STR-PRGRP sy-vline
WA_FIS_CF_FC_STR-COLOR sy-vline
WA_FIS_CF_FC_STR-FPAGE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.