ABAP Select data from SAP table FINSV_MP_ST_AG2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FINSV_MP_ST_AG2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FINSV_MP_ST_AG2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FINSV_MP_ST_AG2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FINSV_MP_ST_AG2 TYPE STANDARD TABLE OF FINSV_MP_ST_AG2,
      WA_FINSV_MP_ST_AG2 TYPE FINSV_MP_ST_AG2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FINSV_MP_ST_AG2> TYPE FINSV_MP_ST_AG2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FINSV_MP_ST_AG2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FINSV_MP_ST_AG2
  INTO TABLE IT_FINSV_MP_ST_AG2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FINSV_MP_ST_AG2
*  INTO TABLE @DATA(IT_FINSV_MP_ST_AG22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FINSV_MP_ST_AG2 INDEX 1 INTO DATA(WA_FINSV_MP_ST_AG22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FINSV_MP_ST_AG2 ASSIGNING <FINSV_MP_ST_AG2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FINSV_MP_ST_AG2>-MANDT = 1.
<FINSV_MP_ST_AG2>-PROJECT_ID = 1.
<FINSV_MP_ST_AG2>-SET_ID = 1.
<FINSV_MP_ST_AG2>-RUN_ID = 1.
<FINSV_MP_ST_AG2>-ITERATION = 1.
ENDLOOP.

LOOP AT IT_FINSV_MP_ST_AG2 INTO WA_FINSV_MP_ST_AG2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FINSV_MP_ST_AG2-START_PROCESSING, sy-vline,
WA_FINSV_MP_ST_AG2-END_PROCESSING, sy-vline,
WA_FINSV_MP_ST_AG2-NUM_SMSG, sy-vline,
WA_FINSV_MP_ST_AG2-NUM_IMSG, sy-vline,
WA_FINSV_MP_ST_AG2-NUM_WMSG, sy-vline,
WA_FINSV_MP_ST_AG2-NUM_EMSG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FINSV_MP_ST_AG2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FINSV_MP_ST_AG2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FINSV_MP_ST_AG2 INTO WA_FINSV_MP_ST_AG2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PROJECT_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINSV_MP_ST_AG2-PROJECT_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINSV_MP_ST_AG2-PROJECT_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FINSV_MP_ST_AG2_STR,
MANDT TYPE STRING,
PROJECT_ID TYPE STRING,
SET_ID TYPE STRING,
RUN_ID TYPE STRING,
ITERATION TYPE STRING,
START_PROCESSING TYPE STRING,
END_PROCESSING TYPE STRING,
NUM_SMSG TYPE STRING,
NUM_IMSG TYPE STRING,
NUM_WMSG TYPE STRING,
NUM_EMSG TYPE STRING,
X_RESET TYPE STRING,
NUM_0 TYPE STRING,
NUM_1 TYPE STRING,
NUM_3 TYPE STRING,
NUM_4 TYPE STRING,
NUM_5 TYPE STRING,
NUM_6 TYPE STRING,
NUM_9 TYPE STRING,
NUM_09 TYPE STRING,
NUM_34 TYPE STRING,
NUM_SKIPPED TYPE STRING,
NUM_PROC_SKIPPED TYPE STRING,
NUM_PROC TYPE STRING,
NUM_DONE TYPE STRING,
NUM_USER TYPE STRING,
NUM_SEQUENCE TYPE STRING,
NUM_ALL TYPE STRING,
RUN_STATUS TYPE STRING,
RUN_STATUS_TIME TYPE STRING,
RUN_STATUS_UNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_FINSV_MP_ST_AG2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FINSV_MP_ST_AG2_STR-MANDT sy-vline
WA_FINSV_MP_ST_AG2_STR-PROJECT_ID sy-vline
WA_FINSV_MP_ST_AG2_STR-SET_ID sy-vline
WA_FINSV_MP_ST_AG2_STR-RUN_ID sy-vline
WA_FINSV_MP_ST_AG2_STR-ITERATION sy-vline
WA_FINSV_MP_ST_AG2_STR-START_PROCESSING sy-vline
WA_FINSV_MP_ST_AG2_STR-END_PROCESSING sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_SMSG sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_IMSG sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_WMSG sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_EMSG sy-vline
WA_FINSV_MP_ST_AG2_STR-X_RESET sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_0 sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_1 sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_3 sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_4 sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_5 sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_6 sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_9 sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_09 sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_34 sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_SKIPPED sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_PROC_SKIPPED sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_PROC sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_DONE sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_USER sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_SEQUENCE sy-vline
WA_FINSV_MP_ST_AG2_STR-NUM_ALL sy-vline
WA_FINSV_MP_ST_AG2_STR-RUN_STATUS sy-vline
WA_FINSV_MP_ST_AG2_STR-RUN_STATUS_TIME sy-vline
WA_FINSV_MP_ST_AG2_STR-RUN_STATUS_UNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.