ABAP Select data from SAP table FINS_CO_SETTLING_INFO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FINS_CO_SETTLING_INFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FINS_CO_SETTLING_INFO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FINS_CO_SETTLING_INFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FINS_CO_SETTLING_INFO TYPE STANDARD TABLE OF FINS_CO_SETTLING_INFO,
      WA_FINS_CO_SETTLING_INFO TYPE FINS_CO_SETTLING_INFO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FINS_CO_SETTLING_INFO> TYPE FINS_CO_SETTLING_INFO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FINS_CO_SETTLING_INFO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FINS_CO_SETTLING_INFO
  INTO TABLE IT_FINS_CO_SETTLING_INFO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FINS_CO_SETTLING_INFO
*  INTO TABLE @DATA(IT_FINS_CO_SETTLING_INFO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FINS_CO_SETTLING_INFO INDEX 1 INTO DATA(WA_FINS_CO_SETTLING_INFO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FINS_CO_SETTLING_INFO ASSIGNING <FINS_CO_SETTLING_INFO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FINS_CO_SETTLING_INFO>-KOKRS = 1.
<FINS_CO_SETTLING_INFO>-TEMP_BELNR = 1.
<FINS_CO_SETTLING_INFO>-BUZEI = 1.
<FINS_CO_SETTLING_INFO>-BW_REFBZ = 1.
<FINS_CO_SETTLING_INFO>-PREC_CO_BELNR = 1.
ENDLOOP.

LOOP AT IT_FINS_CO_SETTLING_INFO INTO WA_FINS_CO_SETTLING_INFO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FINS_CO_SETTLING_INFO-PREC_CO_BUZEI, sy-vline,
WA_FINS_CO_SETTLING_INFO-PREC_BW_REFBZ, sy-vline,
WA_FINS_CO_SETTLING_INFO-PREC_AWTYP, sy-vline,
WA_FINS_CO_SETTLING_INFO-PREC_AWORG, sy-vline,
WA_FINS_CO_SETTLING_INFO-PREC_AWREF, sy-vline,
WA_FINS_CO_SETTLING_INFO-PREC_AWSYS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FINS_CO_SETTLING_INFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FINS_CO_SETTLING_INFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FINS_CO_SETTLING_INFO INTO WA_FINS_CO_SETTLING_INFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field TEMP_BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CO_SETTLING_INFO-TEMP_BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CO_SETTLING_INFO-TEMP_BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PREC_CO_BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CO_SETTLING_INFO-PREC_CO_BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CO_SETTLING_INFO-PREC_CO_BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PREC_AWREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CO_SETTLING_INFO-PREC_AWREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CO_SETTLING_INFO-PREC_AWREF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PREC_AWSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CO_SETTLING_INFO-PREC_AWSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CO_SETTLING_INFO-PREC_AWSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PREC_CO_BELNR_SENDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CO_SETTLING_INFO-PREC_CO_BELNR_SENDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CO_SETTLING_INFO-PREC_CO_BELNR_SENDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PREC_LOGSYSTEM_SENDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CO_SETTLING_INFO-PREC_LOGSYSTEM_SENDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CO_SETTLING_INFO-PREC_LOGSYSTEM_SENDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CO_SETTLING_INFO-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CO_SETTLING_INFO-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BEKNZ, internal->external for field BEKNZ CALL FUNCTION 'CONVERSION_EXIT_BEKNZ_OUTPUT' EXPORTING input = WA_FINS_CO_SETTLING_INFO-BEKNZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CO_SETTLING_INFO-BEKNZ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FINS_CO_SETTLING_INFO_STR,
KOKRS TYPE STRING,
TEMP_BELNR TYPE STRING,
BUZEI TYPE STRING,
BW_REFBZ TYPE STRING,
PREC_CO_BELNR TYPE STRING,
PREC_CO_BUZEI TYPE STRING,
PREC_BW_REFBZ TYPE STRING,
PREC_AWTYP TYPE STRING,
PREC_AWORG TYPE STRING,
PREC_AWREF TYPE STRING,
PREC_AWSYS TYPE STRING,
PREC_AWITEM TYPE STRING,
PREC_SUBTA TYPE STRING,
PREC_CO_ZLENR TYPE STRING,
PREC_CO_BELKZ TYPE STRING,
PREC_DRCRK TYPE STRING,
PREC_CO_BELNR_SENDER TYPE STRING,
PREC_KOKRS_SENDER TYPE STRING,
PREC_LOGSYSTEM_SENDER TYPE STRING,
BTTYPE_CO TYPE STRING,
PREC_BUKRS TYPE STRING,
VERSN TYPE STRING,
BEKNZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_FINS_CO_SETTLING_INFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FINS_CO_SETTLING_INFO_STR-KOKRS sy-vline
WA_FINS_CO_SETTLING_INFO_STR-TEMP_BELNR sy-vline
WA_FINS_CO_SETTLING_INFO_STR-BUZEI sy-vline
WA_FINS_CO_SETTLING_INFO_STR-BW_REFBZ sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_CO_BELNR sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_CO_BUZEI sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_BW_REFBZ sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_AWTYP sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_AWORG sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_AWREF sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_AWSYS sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_AWITEM sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_SUBTA sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_CO_ZLENR sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_CO_BELKZ sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_DRCRK sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_CO_BELNR_SENDER sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_KOKRS_SENDER sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_LOGSYSTEM_SENDER sy-vline
WA_FINS_CO_SETTLING_INFO_STR-BTTYPE_CO sy-vline
WA_FINS_CO_SETTLING_INFO_STR-PREC_BUKRS sy-vline
WA_FINS_CO_SETTLING_INFO_STR-VERSN sy-vline
WA_FINS_CO_SETTLING_INFO_STR-BEKNZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.