ABAP Select data from SAP table FINS_CFIN_S_AIF_ACCIT_WT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FINS_CFIN_S_AIF_ACCIT_WT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FINS_CFIN_S_AIF_ACCIT_WT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FINS_CFIN_S_AIF_ACCIT_WT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FINS_CFIN_S_AIF_ACCIT_WT TYPE STANDARD TABLE OF FINS_CFIN_S_AIF_ACCIT_WT,
      WA_FINS_CFIN_S_AIF_ACCIT_WT TYPE FINS_CFIN_S_AIF_ACCIT_WT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FINS_CFIN_S_AIF_ACCIT_WT> TYPE FINS_CFIN_S_AIF_ACCIT_WT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FINS_CFIN_S_AIF_ACCIT_WT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FINS_CFIN_S_AIF_ACCIT_WT
  INTO TABLE IT_FINS_CFIN_S_AIF_ACCIT_WT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FINS_CFIN_S_AIF_ACCIT_WT
*  INTO TABLE @DATA(IT_FINS_CFIN_S_AIF_ACCIT_WT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FINS_CFIN_S_AIF_ACCIT_WT INDEX 1 INTO DATA(WA_FINS_CFIN_S_AIF_ACCIT_WT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FINS_CFIN_S_AIF_ACCIT_WT ASSIGNING <FINS_CFIN_S_AIF_ACCIT_WT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FINS_CFIN_S_AIF_ACCIT_WT>-WT_KEY = 1.
<FINS_CFIN_S_AIF_ACCIT_WT>-WITHT = 1.
<FINS_CFIN_S_AIF_ACCIT_WT>-WT_WITHCD = 1.
<FINS_CFIN_S_AIF_ACCIT_WT>-WT_QSSHH = 1.
<FINS_CFIN_S_AIF_ACCIT_WT>-WT_QSSHB = 1.
ENDLOOP.

LOOP AT IT_FINS_CFIN_S_AIF_ACCIT_WT INTO WA_FINS_CFIN_S_AIF_ACCIT_WT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSSH2, sy-vline,
WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSSH3, sy-vline,
WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIHH, sy-vline,
WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIHB, sy-vline,
WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIH2, sy-vline,
WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIH3, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FINS_CFIN_S_AIF_ACCIT_WT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FINS_CFIN_S_AIF_ACCIT_WT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FINS_CFIN_S_AIF_ACCIT_WT INTO WA_FINS_CFIN_S_AIF_ACCIT_WT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AC152, internal->external for field WT_QSSHH CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSSHH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSSHH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QSSHB CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSSHB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSSHB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QSSH2 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSSH2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSSH2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QSSH3 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSSH3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSSH3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBUIHH CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIHH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIHH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBUIHB CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIHB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIHB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBUIH2 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIH2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIH2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBUIH3 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIH3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBUIH3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WDMBTR CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_WDMBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_WDMBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WWRBTR CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_WWRBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_WWRBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WDMBT2 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_WDMBT2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_WDMBT2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WDMBT3 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_WDMBT3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_WDMBT3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBSHH CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSHH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSHH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBSHB CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSHB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSHB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBSH2 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSH2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSH2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBSH3 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSH3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSH3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBSHHA CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSHHA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSHHA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBSHHB CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSHHB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QBSHHB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QSFHH CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSFHH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSFHH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QSFHB CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSFHB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSFHB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QSFH2 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSFH2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSFH2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QSFH3 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSFH3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_QSFH3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-HKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKONT_OPP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-HKONT_OPP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-HKONT_OPP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUGBL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-AUGBL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-AUGBL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WT_LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINS_CFIN_S_AIF_ACCIT_WT-WT_LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FINS_CFIN_S_AIF_ACCIT_WT_STR,
WT_KEY TYPE STRING,
WITHT TYPE STRING,
WT_WITHCD TYPE STRING,
WT_QSSHH TYPE STRING,
WT_QSSHB TYPE STRING,
WT_QSSH2 TYPE STRING,
WT_QSSH3 TYPE STRING,
WT_QBUIHH TYPE STRING,
WT_QBUIHB TYPE STRING,
WT_QBUIH2 TYPE STRING,
WT_QBUIH3 TYPE STRING,
WT_WDMBTR TYPE STRING,
WT_WWRBTR TYPE STRING,
WT_WDMBT2 TYPE STRING,
WT_WDMBT3 TYPE STRING,
WT_BASMAN TYPE STRING,
WT_AMNMAN TYPE STRING,
WT_QBSHH TYPE STRING,
WT_QBSHB TYPE STRING,
WT_QBSH2 TYPE STRING,
WT_QBSH3 TYPE STRING,
WT_QBSHHA TYPE STRING,
WT_QBSHHB TYPE STRING,
WT_STAT TYPE STRING,
WT_QSFHH TYPE STRING,
WT_QSFHB TYPE STRING,
WT_QSFH2 TYPE STRING,
WT_QSFH3 TYPE STRING,
WT_WTEXMN TYPE STRING,
KOART TYPE STRING,
WT_ACCO TYPE STRING,
HKONT TYPE STRING,
HKONT_OPP TYPE STRING,
QSREC TYPE STRING,
AUGBL TYPE STRING,
AUGDT TYPE STRING,
WT_QSZRT TYPE STRING,
TEXT15 TYPE STRING,
QSATZ TYPE STRING,
WT_SLFWTPD TYPE STRING,
WT_GRUWTPD TYPE STRING,
WT_OPOWTPD TYPE STRING,
WT_GIVENPD TYPE STRING,
CTNUMBER TYPE STRING,
WT_DOWNC TYPE STRING,
WT_RESITEM TYPE STRING,
CTISSUEDATE TYPE STRING,
WT_CALC TYPE STRING,
WT_LOGSYS TYPE STRING,END OF T_EKKO_STR. DATA: WA_FINS_CFIN_S_AIF_ACCIT_WT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_KEY sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WITHT sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_WITHCD sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QSSHH sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QSSHB sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QSSH2 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QSSH3 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QBUIHH sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QBUIHB sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QBUIH2 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QBUIH3 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_WDMBTR sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_WWRBTR sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_WDMBT2 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_WDMBT3 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_BASMAN sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_AMNMAN sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QBSHH sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QBSHB sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QBSH2 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QBSH3 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QBSHHA sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QBSHHB sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_STAT sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QSFHH sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QSFHB sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QSFH2 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QSFH3 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_WTEXMN sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-KOART sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_ACCO sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-HKONT sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-HKONT_OPP sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-QSREC sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-AUGBL sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-AUGDT sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_QSZRT sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-TEXT15 sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-QSATZ sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_SLFWTPD sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_GRUWTPD sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_OPOWTPD sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_GIVENPD sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-CTNUMBER sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_DOWNC sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_RESITEM sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-CTISSUEDATE sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_CALC sy-vline
WA_FINS_CFIN_S_AIF_ACCIT_WT_STR-WT_LOGSYS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.