ABAP Select data from SAP table FICOS_STR_API_DATE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FICOS_STR_API_DATE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FICOS_STR_API_DATE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FICOS_STR_API_DATE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FICOS_STR_API_DATE TYPE STANDARD TABLE OF FICOS_STR_API_DATE,
      WA_FICOS_STR_API_DATE TYPE FICOS_STR_API_DATE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FICOS_STR_API_DATE> TYPE FICOS_STR_API_DATE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FICOS_STR_API_DATE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FICOS_STR_API_DATE
  INTO TABLE IT_FICOS_STR_API_DATE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FICOS_STR_API_DATE
*  INTO TABLE @DATA(IT_FICOS_STR_API_DATE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FICOS_STR_API_DATE INDEX 1 INTO DATA(WA_FICOS_STR_API_DATE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FICOS_STR_API_DATE ASSIGNING <FICOS_STR_API_DATE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FICOS_STR_API_DATE>-EXTKEY_COND = 1.
<FICOS_STR_API_DATE>-EXTKEY_COMP = 1.
<FICOS_STR_API_DATE>-I_COND = 1.
<FICOS_STR_API_DATE>-D_VALIDFROM = 1.
<FICOS_STR_API_DATE>-F_VALIDFROMINC = 1.
ENDLOOP.

LOOP AT IT_FICOS_STR_API_DATE INTO WA_FICOS_STR_API_DATE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FICOS_STR_API_DATE-F_VALIDFROMULT, sy-vline,
WA_FICOS_STR_API_DATE-D_VALIDTO, sy-vline,
WA_FICOS_STR_API_DATE-F_VALIDTOINC, sy-vline,
WA_FICOS_STR_API_DATE-F_VALIDTOULT, sy-vline,
WA_FICOS_STR_API_DATE-O_LEVEL, sy-vline,
WA_FICOS_STR_API_DATE-O_LEVELTOFROM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FICOS_STR_API_DATE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FICOS_STR_API_DATE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FICOS_STR_API_DATE INTO WA_FICOS_STR_API_DATE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FICOS_STR_API_DATE_STR,
EXTKEY_COND TYPE STRING,
EXTKEY_COMP TYPE STRING,
I_COND TYPE STRING,
D_VALIDFROM TYPE STRING,
F_VALIDFROMINC TYPE STRING,
F_VALIDFROMULT TYPE STRING,
D_VALIDTO TYPE STRING,
F_VALIDTOINC TYPE STRING,
F_VALIDTOULT TYPE STRING,
O_LEVEL TYPE STRING,
O_LEVELTOFROM TYPE STRING,
F_ZEROCOND TYPE STRING,
O_TIMELIM TYPE STRING,
O_LEVELEVAL TYPE STRING,
O_STATUS TYPE STRING,
F_CORRESPONDENCE TYPE STRING,
O_LEVELTOFREVAL TYPE STRING,
O_RELCONDTYPE TYPE STRING,
F_NOINHERITANCE TYPE STRING,
O_CONDSOURCE TYPE STRING,
I_LIST_SOURCE TYPE STRING,
O_REFUND TYPE STRING,
I_BASIS_ORDER TYPE STRING,
I_COMP_REL TYPE STRING,
O_DATECATG TYPE STRING,
N_REPPERIOD TYPE STRING,
O_REPUNIT TYPE STRING,
O_KEYDATE TYPE STRING,
D_STARTDATE TYPE STRING,
F_STARTDATEINC TYPE STRING,
F_STARTDATEULT TYPE STRING,
O_DATERULE TYPE STRING,
O_PULLDATE TYPE STRING,
O_RHYTHMCATG TYPE STRING,
O_REFSTARTDATE TYPE STRING,
N_REFSTARTNUM TYPE STRING,
U_REFSTARTUNIT TYPE STRING,
F_FIXEDPERIOD TYPE STRING,
O_RELDATECATG TYPE STRING,
O_RELDATESHIFT TYPE STRING,
O_REL_MISC TYPE STRING,
O_CAL1 TYPE STRING,
O_CAL2 TYPE STRING,
O_CAL3 TYPE STRING,
O_CAL5 TYPE STRING,
O_CAL6 TYPE STRING,
O_KEYDATES40 TYPE STRING,
N_LOCKOUTDAYS TYPE STRING,
I_GRP TYPE STRING,
D_VALIDTO_IMPL TYPE STRING,END OF T_EKKO_STR. DATA: WA_FICOS_STR_API_DATE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FICOS_STR_API_DATE_STR-EXTKEY_COND sy-vline
WA_FICOS_STR_API_DATE_STR-EXTKEY_COMP sy-vline
WA_FICOS_STR_API_DATE_STR-I_COND sy-vline
WA_FICOS_STR_API_DATE_STR-D_VALIDFROM sy-vline
WA_FICOS_STR_API_DATE_STR-F_VALIDFROMINC sy-vline
WA_FICOS_STR_API_DATE_STR-F_VALIDFROMULT sy-vline
WA_FICOS_STR_API_DATE_STR-D_VALIDTO sy-vline
WA_FICOS_STR_API_DATE_STR-F_VALIDTOINC sy-vline
WA_FICOS_STR_API_DATE_STR-F_VALIDTOULT sy-vline
WA_FICOS_STR_API_DATE_STR-O_LEVEL sy-vline
WA_FICOS_STR_API_DATE_STR-O_LEVELTOFROM sy-vline
WA_FICOS_STR_API_DATE_STR-F_ZEROCOND sy-vline
WA_FICOS_STR_API_DATE_STR-O_TIMELIM sy-vline
WA_FICOS_STR_API_DATE_STR-O_LEVELEVAL sy-vline
WA_FICOS_STR_API_DATE_STR-O_STATUS sy-vline
WA_FICOS_STR_API_DATE_STR-F_CORRESPONDENCE sy-vline
WA_FICOS_STR_API_DATE_STR-O_LEVELTOFREVAL sy-vline
WA_FICOS_STR_API_DATE_STR-O_RELCONDTYPE sy-vline
WA_FICOS_STR_API_DATE_STR-F_NOINHERITANCE sy-vline
WA_FICOS_STR_API_DATE_STR-O_CONDSOURCE sy-vline
WA_FICOS_STR_API_DATE_STR-I_LIST_SOURCE sy-vline
WA_FICOS_STR_API_DATE_STR-O_REFUND sy-vline
WA_FICOS_STR_API_DATE_STR-I_BASIS_ORDER sy-vline
WA_FICOS_STR_API_DATE_STR-I_COMP_REL sy-vline
WA_FICOS_STR_API_DATE_STR-O_DATECATG sy-vline
WA_FICOS_STR_API_DATE_STR-N_REPPERIOD sy-vline
WA_FICOS_STR_API_DATE_STR-O_REPUNIT sy-vline
WA_FICOS_STR_API_DATE_STR-O_KEYDATE sy-vline
WA_FICOS_STR_API_DATE_STR-D_STARTDATE sy-vline
WA_FICOS_STR_API_DATE_STR-F_STARTDATEINC sy-vline
WA_FICOS_STR_API_DATE_STR-F_STARTDATEULT sy-vline
WA_FICOS_STR_API_DATE_STR-O_DATERULE sy-vline
WA_FICOS_STR_API_DATE_STR-O_PULLDATE sy-vline
WA_FICOS_STR_API_DATE_STR-O_RHYTHMCATG sy-vline
WA_FICOS_STR_API_DATE_STR-O_REFSTARTDATE sy-vline
WA_FICOS_STR_API_DATE_STR-N_REFSTARTNUM sy-vline
WA_FICOS_STR_API_DATE_STR-U_REFSTARTUNIT sy-vline
WA_FICOS_STR_API_DATE_STR-F_FIXEDPERIOD sy-vline
WA_FICOS_STR_API_DATE_STR-O_RELDATECATG sy-vline
WA_FICOS_STR_API_DATE_STR-O_RELDATESHIFT sy-vline
WA_FICOS_STR_API_DATE_STR-O_REL_MISC sy-vline
WA_FICOS_STR_API_DATE_STR-O_CAL1 sy-vline
WA_FICOS_STR_API_DATE_STR-O_CAL2 sy-vline
WA_FICOS_STR_API_DATE_STR-O_CAL3 sy-vline
WA_FICOS_STR_API_DATE_STR-O_CAL5 sy-vline
WA_FICOS_STR_API_DATE_STR-O_CAL6 sy-vline
WA_FICOS_STR_API_DATE_STR-O_KEYDATES40 sy-vline
WA_FICOS_STR_API_DATE_STR-N_LOCKOUTDAYS sy-vline
WA_FICOS_STR_API_DATE_STR-I_GRP sy-vline
WA_FICOS_STR_API_DATE_STR-D_VALIDTO_IMPL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.