ABAP Select data from SAP table FIARSEPA_S_BOE_ALV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FIARSEPA_S_BOE_ALV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FIARSEPA_S_BOE_ALV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FIARSEPA_S_BOE_ALV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FIARSEPA_S_BOE_ALV TYPE STANDARD TABLE OF FIARSEPA_S_BOE_ALV,
      WA_FIARSEPA_S_BOE_ALV TYPE FIARSEPA_S_BOE_ALV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FIARSEPA_S_BOE_ALV> TYPE FIARSEPA_S_BOE_ALV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FIARSEPA_S_BOE_ALV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FIARSEPA_S_BOE_ALV
  INTO TABLE IT_FIARSEPA_S_BOE_ALV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FIARSEPA_S_BOE_ALV
*  INTO TABLE @DATA(IT_FIARSEPA_S_BOE_ALV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FIARSEPA_S_BOE_ALV INDEX 1 INTO DATA(WA_FIARSEPA_S_BOE_ALV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FIARSEPA_S_BOE_ALV ASSIGNING <FIARSEPA_S_BOE_ALV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FIARSEPA_S_BOE_ALV>-ICON = 1.
<FIARSEPA_S_BOE_ALV>-MESSG = 1.
<FIARSEPA_S_BOE_ALV>-BUKRS = 1.
<FIARSEPA_S_BOE_ALV>-VBLNR = 1.
<FIARSEPA_S_BOE_ALV>-GJAHR = 1.
ENDLOOP.

LOOP AT IT_FIARSEPA_S_BOE_ALV INTO WA_FIARSEPA_S_BOE_ALV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FIARSEPA_S_BOE_ALV-LAUFD, sy-vline,
WA_FIARSEPA_S_BOE_ALV-LAUFI, sy-vline,
WA_FIARSEPA_S_BOE_ALV-WEFAE, sy-vline,
WA_FIARSEPA_S_BOE_ALV-WDATE, sy-vline,
WA_FIARSEPA_S_BOE_ALV-BELNR, sy-vline,
WA_FIARSEPA_S_BOE_ALV-DISBJ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FIARSEPA_S_BOE_ALV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FIARSEPA_S_BOE_ALV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FIARSEPA_S_BOE_ALV INTO WA_FIARSEPA_S_BOE_ALV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIARSEPA_S_BOE_ALV-VBLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIARSEPA_S_BOE_ALV-VBLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FIARSEPA_S_BOE_ALV-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIARSEPA_S_BOE_ALV-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIARSEPA_S_BOE_ALV-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIARSEPA_S_BOE_ALV-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field DISBJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FIARSEPA_S_BOE_ALV-DISBJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIARSEPA_S_BOE_ALV-DISBJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIARSEPA_S_BOE_ALV-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIARSEPA_S_BOE_ALV-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIARSEPA_S_BOE_ALV-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIARSEPA_S_BOE_ALV-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field DMBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FIARSEPA_S_BOE_ALV-DMBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIARSEPA_S_BOE_ALV-DMBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field WRBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FIARSEPA_S_BOE_ALV-WRBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIARSEPA_S_BOE_ALV-WRBTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FIARSEPA_S_BOE_ALV_STR,
ICON TYPE STRING,
MESSG TYPE STRING,
BUKRS TYPE STRING,
VBLNR TYPE STRING,
GJAHR TYPE STRING,
LAUFD TYPE STRING,
LAUFI TYPE STRING,
WEFAE TYPE STRING,
WDATE TYPE STRING,
BELNR TYPE STRING,
DISBJ TYPE STRING,
BLDAT TYPE STRING,
BUDAT TYPE STRING,
XBLNR TYPE STRING,
ZUONR TYPE STRING,
BANKA TYPE STRING,
BANKS TYPE STRING,
UIBAN TYPE STRING,
SWIFT TYPE STRING,
UBNKL TYPE STRING,
UBKNT TYPE STRING,
SAKNR TYPE STRING,
HBKID TYPE STRING,
HKTID TYPE STRING,
VALUT TYPE STRING,
KUNNR TYPE STRING,
ZNME1 TYPE STRING,
DMBTR TYPE STRING,
HWAER TYPE STRING,
WRBTR TYPE STRING,
WAERS TYPE STRING,
RZAWE TYPE STRING,
UMSKZ TYPE STRING,
WBZOG TYPE STRING,
WORT2 TYPE STRING,
SND_COUNTRY TYPE STRING,
SND_IBAN TYPE STRING,
SND_BIC TYPE STRING,
ZBNKL TYPE STRING,
ZBNKN TYPE STRING,
BKONT TYPE STRING,
ADDR TYPE STRING,
MNDID TYPE STRING,
BUZEI TYPE STRING,END OF T_EKKO_STR. DATA: WA_FIARSEPA_S_BOE_ALV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-ICON sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-MESSG sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-BUKRS sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-VBLNR sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-GJAHR sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-LAUFD sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-LAUFI sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-WEFAE sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-WDATE sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-BELNR sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-DISBJ sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-BLDAT sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-BUDAT sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-XBLNR sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-ZUONR sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-BANKA sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-BANKS sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-UIBAN sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-SWIFT sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-UBNKL sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-UBKNT sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-SAKNR sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-HBKID sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-HKTID sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-VALUT sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-KUNNR sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-ZNME1 sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-DMBTR sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-HWAER sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-WRBTR sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-WAERS sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-RZAWE sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-UMSKZ sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-WBZOG sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-WORT2 sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-SND_COUNTRY sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-SND_IBAN sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-SND_BIC sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-ZBNKL sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-ZBNKN sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-BKONT sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-ADDR sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-MNDID sy-vline
WA_FIARSEPA_S_BOE_ALV_STR-BUZEI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.