ABAP Select data from SAP table FIAAKW_S_OUTPUT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FIAAKW_S_OUTPUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FIAAKW_S_OUTPUT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FIAAKW_S_OUTPUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FIAAKW_S_OUTPUT TYPE STANDARD TABLE OF FIAAKW_S_OUTPUT,
      WA_FIAAKW_S_OUTPUT TYPE FIAAKW_S_OUTPUT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FIAAKW_S_OUTPUT> TYPE FIAAKW_S_OUTPUT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FIAAKW_S_OUTPUT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FIAAKW_S_OUTPUT
  INTO TABLE IT_FIAAKW_S_OUTPUT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FIAAKW_S_OUTPUT
*  INTO TABLE @DATA(IT_FIAAKW_S_OUTPUT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FIAAKW_S_OUTPUT INDEX 1 INTO DATA(WA_FIAAKW_S_OUTPUT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FIAAKW_S_OUTPUT ASSIGNING <FIAAKW_S_OUTPUT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FIAAKW_S_OUTPUT>-BUKRS = 1.
<FIAAKW_S_OUTPUT>-BUKTXT = 1.
<FIAAKW_S_OUTPUT>-COL_SEQUENCE = 1.
<FIAAKW_S_OUTPUT>-COL_TEXT = 1.
<FIAAKW_S_OUTPUT>-ORD41 = 1.
ENDLOOP.

LOOP AT IT_FIAAKW_S_OUTPUT INTO WA_FIAAKW_S_OUTPUT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FIAAKW_S_OUTPUT-ORDTEXT, sy-vline,
WA_FIAAKW_S_OUTPUT-ANLKL, sy-vline,
WA_FIAAKW_S_OUTPUT-FKBER2, sy-vline,
WA_FIAAKW_S_OUTPUT-ANLN1, sy-vline,
WA_FIAAKW_S_OUTPUT-ANLN2, sy-vline,
WA_FIAAKW_S_OUTPUT-TXT50, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FIAAKW_S_OUTPUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FIAAKW_S_OUTPUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FIAAKW_S_OUTPUT INTO WA_FIAAKW_S_OUTPUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ANLKL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-ANLKL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-ANLKL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLN1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-ANLN1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-ANLN1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLN2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-ANLN2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-ANLN2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field COST_PYEAR CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-COST_PYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-COST_PYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field COST_CYEAR CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-COST_CYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-COST_CYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field ADD_ANN CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-ADD_ANN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-ADD_ANN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DISP_ANN CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-DISP_ANN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-DISP_ANN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DEPR_ANN CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-DEPR_ANN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-DEPR_ANN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DEPR_DISP_ANN CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-DEPR_DISP_ANN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-DEPR_DISP_ANN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DEPR_CYEAR CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-DEPR_CYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-DEPR_CYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DEPR_PYEAR CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-DEPR_PYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-DEPR_PYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field NBV_YEAR CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-NBV_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-NBV_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field NBV_PYEAR CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FIAAKW_S_OUTPUT-NBV_PYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIAAKW_S_OUTPUT-NBV_PYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FIAAKW_S_OUTPUT_STR,
BUKRS TYPE STRING,
BUKTXT TYPE STRING,
COL_SEQUENCE TYPE STRING,
COL_TEXT TYPE STRING,
ORD41 TYPE STRING,
ORDTEXT TYPE STRING,
ANLKL TYPE STRING,
FKBER2 TYPE STRING,
ANLN1 TYPE STRING,
ANLN2 TYPE STRING,
TXT50 TYPE STRING,
AKTIV TYPE STRING,
WAERS TYPE STRING,
COST_PYEAR TYPE STRING,
COST_CYEAR TYPE STRING,
ADD_ANN TYPE STRING,
DISP_ANN TYPE STRING,
DEPR_ANN TYPE STRING,
DEPR_DISP_ANN TYPE STRING,
DEPR_CYEAR TYPE STRING,
DEPR_PYEAR TYPE STRING,
NBV_YEAR TYPE STRING,
NBV_PYEAR TYPE STRING,END OF T_EKKO_STR. DATA: WA_FIAAKW_S_OUTPUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FIAAKW_S_OUTPUT_STR-BUKRS sy-vline
WA_FIAAKW_S_OUTPUT_STR-BUKTXT sy-vline
WA_FIAAKW_S_OUTPUT_STR-COL_SEQUENCE sy-vline
WA_FIAAKW_S_OUTPUT_STR-COL_TEXT sy-vline
WA_FIAAKW_S_OUTPUT_STR-ORD41 sy-vline
WA_FIAAKW_S_OUTPUT_STR-ORDTEXT sy-vline
WA_FIAAKW_S_OUTPUT_STR-ANLKL sy-vline
WA_FIAAKW_S_OUTPUT_STR-FKBER2 sy-vline
WA_FIAAKW_S_OUTPUT_STR-ANLN1 sy-vline
WA_FIAAKW_S_OUTPUT_STR-ANLN2 sy-vline
WA_FIAAKW_S_OUTPUT_STR-TXT50 sy-vline
WA_FIAAKW_S_OUTPUT_STR-AKTIV sy-vline
WA_FIAAKW_S_OUTPUT_STR-WAERS sy-vline
WA_FIAAKW_S_OUTPUT_STR-COST_PYEAR sy-vline
WA_FIAAKW_S_OUTPUT_STR-COST_CYEAR sy-vline
WA_FIAAKW_S_OUTPUT_STR-ADD_ANN sy-vline
WA_FIAAKW_S_OUTPUT_STR-DISP_ANN sy-vline
WA_FIAAKW_S_OUTPUT_STR-DEPR_ANN sy-vline
WA_FIAAKW_S_OUTPUT_STR-DEPR_DISP_ANN sy-vline
WA_FIAAKW_S_OUTPUT_STR-DEPR_CYEAR sy-vline
WA_FIAAKW_S_OUTPUT_STR-DEPR_PYEAR sy-vline
WA_FIAAKW_S_OUTPUT_STR-NBV_YEAR sy-vline
WA_FIAAKW_S_OUTPUT_STR-NBV_PYEAR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.