ABAP Select data from SAP table FGLV_SIL_RP_CC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FGLV_SIL_RP_CC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FGLV_SIL_RP_CC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FGLV_SIL_RP_CC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FGLV_SIL_RP_CC TYPE STANDARD TABLE OF FGLV_SIL_RP_CC,
      WA_FGLV_SIL_RP_CC TYPE FGLV_SIL_RP_CC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FGLV_SIL_RP_CC> TYPE FGLV_SIL_RP_CC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FGLV_SIL_RP_CC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FGLV_SIL_RP_CC
  INTO TABLE IT_FGLV_SIL_RP_CC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FGLV_SIL_RP_CC
*  INTO TABLE @DATA(IT_FGLV_SIL_RP_CC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FGLV_SIL_RP_CC INDEX 1 INTO DATA(WA_FGLV_SIL_RP_CC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FGLV_SIL_RP_CC ASSIGNING <FGLV_SIL_RP_CC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FGLV_SIL_RP_CC>-RCLNT = 1.
<FGLV_SIL_RP_CC>-RLDNR = 1.
<FGLV_SIL_RP_CC>-RBUKRS = 1.
<FGLV_SIL_RP_CC>-BELNR = 1.
<FGLV_SIL_RP_CC>-GJAHR = 1.
ENDLOOP.

LOOP AT IT_FGLV_SIL_RP_CC INTO WA_FGLV_SIL_RP_CC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FGLV_SIL_RP_CC-BUDAT, sy-vline,
WA_FGLV_SIL_RP_CC-BSTAT, sy-vline,
WA_FGLV_SIL_RP_CC-AWTYP, sy-vline,
WA_FGLV_SIL_RP_CC-AWSYS, sy-vline,
WA_FGLV_SIL_RP_CC-AWORG, sy-vline,
WA_FGLV_SIL_RP_CC-AWREF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FGLV_SIL_RP_CC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FGLV_SIL_RP_CC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FGLV_SIL_RP_CC INTO WA_FGLV_SIL_RP_CC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FGLV_SIL_RP_CC-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FGLV_SIL_RP_CC-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FGLV_SIL_RP_CC-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FGLV_SIL_RP_CC-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FGLV_SIL_RP_CC-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FGLV_SIL_RP_CC-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AWSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FGLV_SIL_RP_CC-AWSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FGLV_SIL_RP_CC-AWSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AWREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FGLV_SIL_RP_CC-AWREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FGLV_SIL_RP_CC-AWREF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FGLV_SIL_RP_CC_STR,
RCLNT TYPE STRING,
RLDNR TYPE STRING,
RBUKRS TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BUDAT TYPE STRING,
BSTAT TYPE STRING,
AWTYP TYPE STRING,
AWSYS TYPE STRING,
AWORG TYPE STRING,
AWREF TYPE STRING,
LDGRP TYPE STRING,
BVORG TYPE STRING,
CPUDT TYPE STRING,
CPUTM TYPE STRING,END OF T_EKKO_STR. DATA: WA_FGLV_SIL_RP_CC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FGLV_SIL_RP_CC_STR-RCLNT sy-vline
WA_FGLV_SIL_RP_CC_STR-RLDNR sy-vline
WA_FGLV_SIL_RP_CC_STR-RBUKRS sy-vline
WA_FGLV_SIL_RP_CC_STR-BELNR sy-vline
WA_FGLV_SIL_RP_CC_STR-GJAHR sy-vline
WA_FGLV_SIL_RP_CC_STR-BUDAT sy-vline
WA_FGLV_SIL_RP_CC_STR-BSTAT sy-vline
WA_FGLV_SIL_RP_CC_STR-AWTYP sy-vline
WA_FGLV_SIL_RP_CC_STR-AWSYS sy-vline
WA_FGLV_SIL_RP_CC_STR-AWORG sy-vline
WA_FGLV_SIL_RP_CC_STR-AWREF sy-vline
WA_FGLV_SIL_RP_CC_STR-LDGRP sy-vline
WA_FGLV_SIL_RP_CC_STR-BVORG sy-vline
WA_FGLV_SIL_RP_CC_STR-CPUDT sy-vline
WA_FGLV_SIL_RP_CC_STR-CPUTM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.