ABAP Select data from SAP table FEBSCK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FEBSCK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FEBSCK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FEBSCK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FEBSCK TYPE STANDARD TABLE OF FEBSCK,
      WA_FEBSCK TYPE FEBSCK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FEBSCK> TYPE FEBSCK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FEBSCK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FEBSCK
  INTO TABLE IT_FEBSCK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FEBSCK
*  INTO TABLE @DATA(IT_FEBSCK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FEBSCK INDEX 1 INTO DATA(WA_FEBSCK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FEBSCK ASSIGNING <FEBSCK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FEBSCK>-SCHNR_PRSC = 1.
<FEBSCK>-SCH10_PRSC = 1.
<FEBSCK>-SCH03_PRSC = 1.
<FEBSCK>-AUSST_PR = 1.
<FEBSCK>-BNKLZ_PRBL = 1.
ENDLOOP.

LOOP AT IT_FEBSCK INTO WA_FEBSCK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FEBSCK-BNK08_PRBL, sy-vline,
WA_FEBSCK-KTONR_PRKT, sy-vline,
WA_FEBSCK-BELNR, sy-vline,
WA_FEBSCK-KUNNR, sy-vline,
WA_FEBSCK-KUNNR_MC, sy-vline,
WA_FEBSCK-BLDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FEBSCK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FEBSCK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FEBSCK INTO WA_FEBSCK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FEBSCK-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEBSCK-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FEBSCK-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEBSCK-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field WRBTR CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FEBSCK-WRBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEBSCK-WRBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FEBSCK-VERTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEBSCK-VERTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REBZG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FEBSCK-REBZG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEBSCK-REBZG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR_KF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FEBSCK-PRCTR_KF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEBSCK-PRCTR_KF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FEBSCK_STR,
SCHNR_PRSC TYPE STRING,
SCH10_PRSC TYPE STRING,
SCH03_PRSC TYPE STRING,
AUSST_PR TYPE STRING,
BNKLZ_PRBL TYPE STRING,
BNK08_PRBL TYPE STRING,
KTONR_PRKT TYPE STRING,
BELNR TYPE STRING,
KUNNR TYPE STRING,
KUNNR_MC TYPE STRING,
BLDAT TYPE STRING,
BUDAT TYPE STRING,
VALTA TYPE STRING,
WRBTR TYPE STRING,
ZUONR TYPE STRING,
XBLNR TYPE STRING,
VERTN TYPE STRING,
VBEWA TYPE STRING,
DEPOT TYPE STRING,
KIDNO TYPE STRING,
REBZG TYPE STRING,
BUKRS_KF TYPE STRING,
XBLNR_KF TYPE STRING,
GSBER_KF TYPE STRING,
VERTT_KF TYPE STRING,
SGTXT_KF TYPE STRING,
KIDNO_KF TYPE STRING,
PRCTR_KF TYPE STRING,
PIBAN_KF TYPE STRING,END OF T_EKKO_STR. DATA: WA_FEBSCK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FEBSCK_STR-SCHNR_PRSC sy-vline
WA_FEBSCK_STR-SCH10_PRSC sy-vline
WA_FEBSCK_STR-SCH03_PRSC sy-vline
WA_FEBSCK_STR-AUSST_PR sy-vline
WA_FEBSCK_STR-BNKLZ_PRBL sy-vline
WA_FEBSCK_STR-BNK08_PRBL sy-vline
WA_FEBSCK_STR-KTONR_PRKT sy-vline
WA_FEBSCK_STR-BELNR sy-vline
WA_FEBSCK_STR-KUNNR sy-vline
WA_FEBSCK_STR-KUNNR_MC sy-vline
WA_FEBSCK_STR-BLDAT sy-vline
WA_FEBSCK_STR-BUDAT sy-vline
WA_FEBSCK_STR-VALTA sy-vline
WA_FEBSCK_STR-WRBTR sy-vline
WA_FEBSCK_STR-ZUONR sy-vline
WA_FEBSCK_STR-XBLNR sy-vline
WA_FEBSCK_STR-VERTN sy-vline
WA_FEBSCK_STR-VBEWA sy-vline
WA_FEBSCK_STR-DEPOT sy-vline
WA_FEBSCK_STR-KIDNO sy-vline
WA_FEBSCK_STR-REBZG sy-vline
WA_FEBSCK_STR-BUKRS_KF sy-vline
WA_FEBSCK_STR-XBLNR_KF sy-vline
WA_FEBSCK_STR-GSBER_KF sy-vline
WA_FEBSCK_STR-VERTT_KF sy-vline
WA_FEBSCK_STR-SGTXT_KF sy-vline
WA_FEBSCK_STR-KIDNO_KF sy-vline
WA_FEBSCK_STR-PRCTR_KF sy-vline
WA_FEBSCK_STR-PIBAN_KF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.