ABAP Select data from SAP table FEB_BSPROC_DETAIL_FE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FEB_BSPROC_DETAIL_FE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FEB_BSPROC_DETAIL_FE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FEB_BSPROC_DETAIL_FE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FEB_BSPROC_DETAIL_FE TYPE STANDARD TABLE OF FEB_BSPROC_DETAIL_FE,
      WA_FEB_BSPROC_DETAIL_FE TYPE FEB_BSPROC_DETAIL_FE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FEB_BSPROC_DETAIL_FE> TYPE FEB_BSPROC_DETAIL_FE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FEB_BSPROC_DETAIL_FE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FEB_BSPROC_DETAIL_FE
  INTO TABLE IT_FEB_BSPROC_DETAIL_FE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FEB_BSPROC_DETAIL_FE
*  INTO TABLE @DATA(IT_FEB_BSPROC_DETAIL_FE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FEB_BSPROC_DETAIL_FE INDEX 1 INTO DATA(WA_FEB_BSPROC_DETAIL_FE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FEB_BSPROC_DETAIL_FE ASSIGNING <FEB_BSPROC_DETAIL_FE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FEB_BSPROC_DETAIL_FE>-BUKRS = 1.
<FEB_BSPROC_DETAIL_FE>-HBKID = 1.
<FEB_BSPROC_DETAIL_FE>-HKTID = 1.
<FEB_BSPROC_DETAIL_FE>-VGINT = 1.
<FEB_BSPROC_DETAIL_FE>-VGINT_TXT = 1.
ENDLOOP.

LOOP AT IT_FEB_BSPROC_DETAIL_FE INTO WA_FEB_BSPROC_DETAIL_FE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FEB_BSPROC_DETAIL_FE-AVKOA, sy-vline,
WA_FEB_BSPROC_DETAIL_FE-AVKON, sy-vline,
WA_FEB_BSPROC_DETAIL_FE-PARTN, sy-vline,
WA_FEB_BSPROC_DETAIL_FE-TATYP, sy-vline,
WA_FEB_BSPROC_DETAIL_FE-CHECT, sy-vline,
WA_FEB_BSPROC_DETAIL_FE-GRPNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FEB_BSPROC_DETAIL_FE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FEB_BSPROC_DETAIL_FE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FEB_BSPROC_DETAIL_FE INTO WA_FEB_BSPROC_DETAIL_FE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AVKON CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FEB_BSPROC_DETAIL_FE-AVKON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEB_BSPROC_DETAIL_FE-AVKON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field CURR_RATE CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_FEB_BSPROC_DETAIL_FE-CURR_RATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEB_BSPROC_DETAIL_FE-CURR_RATE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field FWBTR CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FEB_BSPROC_DETAIL_FE-FWBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEB_BSPROC_DETAIL_FE-FWBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TRANS_AMT CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FEB_BSPROC_DETAIL_FE-TRANS_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEB_BSPROC_DETAIL_FE-TRANS_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field ASSIGNED_AMT CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FEB_BSPROC_DETAIL_FE-ASSIGNED_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEB_BSPROC_DETAIL_FE-ASSIGNED_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field ON_ACC_AMT CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FEB_BSPROC_DETAIL_FE-ON_ACC_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEB_BSPROC_DETAIL_FE-ON_ACC_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field ACC_ASSIGN_AMT CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FEB_BSPROC_DETAIL_FE-ACC_ASSIGN_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEB_BSPROC_DETAIL_FE-ACC_ASSIGN_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field DME_AMT CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FEB_BSPROC_DETAIL_FE-DME_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEB_BSPROC_DETAIL_FE-DME_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field OPEN_AMT CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FEB_BSPROC_DETAIL_FE-OPEN_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEB_BSPROC_DETAIL_FE-OPEN_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU172, internal->external for field ON_ACC_AMT_FOOTER CALL FUNCTION 'CONVERSION_EXIT_AU172_OUTPUT' EXPORTING input = WA_FEB_BSPROC_DETAIL_FE-ON_ACC_AMT_FOOTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FEB_BSPROC_DETAIL_FE-ON_ACC_AMT_FOOTER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FEB_BSPROC_DETAIL_FE_STR,
BUKRS TYPE STRING,
HBKID TYPE STRING,
HKTID TYPE STRING,
VGINT TYPE STRING,
VGINT_TXT TYPE STRING,
AVKOA TYPE STRING,
AVKON TYPE STRING,
PARTN TYPE STRING,
TATYP TYPE STRING,
CHECT TYPE STRING,
GRPNR TYPE STRING,
RSTGR TYPE STRING,
STATUS_ICON TYPE STRING,
VALUT TYPE STRING,
BUDAT TYPE STRING,
VB1OK TYPE STRING,
VB2OK TYPE STRING,
XDIFPO TYPE STRING,
MAX_NO TYPE STRING,
DIFF_MORE_BUT TYPE STRING,
B1APP TYPE STRING,
B2APP TYPE STRING,
CURR_RATE TYPE STRING,
FWBTR TYPE STRING,
FWAER TYPE STRING,
X_FWBTR_CHG TYPE STRING,
XRATE TYPE STRING,
XRATE_TXT TYPE STRING,
KWAER TYPE STRING,
TRANS_AMT TYPE STRING,
TRANS_AMT_CURR TYPE STRING,
FORM_TRANS_AMT TYPE STRING,
ASSIGNED_AMT TYPE STRING,
ASSIGNED_AMT_CURR TYPE STRING,
ASSIGNED_AMT_SIGN TYPE STRING,
FORM_ASSIGNED_AMT TYPE STRING,
ON_ACC_AMT TYPE STRING,
ON_ACC_AMT_SIGN TYPE STRING,
ON_ACC_AMT_CURR TYPE STRING,
FORM_ON_ACC_AMT TYPE STRING,
ACC_ASSIGN_AMT TYPE STRING,
ACC_ASSIGN_AMT_CURR TYPE STRING,
ACC_ASSIGN_AMT_SIGN TYPE STRING,
FORM_ACC_ASSIGN_AMT TYPE STRING,
DME_AMT TYPE STRING,
DME_AMT_CURR TYPE STRING,
DME_AMT_SIGN TYPE STRING,
FORM_DME_AMT TYPE STRING,
OPEN_AMT TYPE STRING,
OPEN_AMT_CURR TYPE STRING,
FORM_OPEN_AMT TYPE STRING,
ON_ACC_AMT_DEBCRED_IND TYPE STRING,
ON_ACC_AMT_FOOTER TYPE STRING,
ON_ACC_AMT_FOOTER_CURR TYPE STRING,
SVAVS TYPE STRING,
N2PCH TYPE STRING,
AVSID TYPE STRING,
FNAM1 TYPE STRING,
FVAL1 TYPE STRING,
FKOA1 TYPE STRING,
FNAM2 TYPE STRING,
FVAL2 TYPE STRING,
FKOA2 TYPE STRING,
FNAM3 TYPE STRING,
FVAL3 TYPE STRING,
FKOA3 TYPE STRING,END OF T_EKKO_STR. DATA: WA_FEB_BSPROC_DETAIL_FE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-BUKRS sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-HBKID sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-HKTID sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-VGINT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-VGINT_TXT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-AVKOA sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-AVKON sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-PARTN sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-TATYP sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-CHECT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-GRPNR sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-RSTGR sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-STATUS_ICON sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-VALUT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-BUDAT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-VB1OK sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-VB2OK sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-XDIFPO sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-MAX_NO sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-DIFF_MORE_BUT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-B1APP sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-B2APP sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-CURR_RATE sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FWBTR sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FWAER sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-X_FWBTR_CHG sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-XRATE sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-XRATE_TXT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-KWAER sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-TRANS_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-TRANS_AMT_CURR sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FORM_TRANS_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ASSIGNED_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ASSIGNED_AMT_CURR sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ASSIGNED_AMT_SIGN sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FORM_ASSIGNED_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ON_ACC_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ON_ACC_AMT_SIGN sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ON_ACC_AMT_CURR sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FORM_ON_ACC_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ACC_ASSIGN_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ACC_ASSIGN_AMT_CURR sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ACC_ASSIGN_AMT_SIGN sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FORM_ACC_ASSIGN_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-DME_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-DME_AMT_CURR sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-DME_AMT_SIGN sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FORM_DME_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-OPEN_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-OPEN_AMT_CURR sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FORM_OPEN_AMT sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ON_ACC_AMT_DEBCRED_IND sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ON_ACC_AMT_FOOTER sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-ON_ACC_AMT_FOOTER_CURR sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-SVAVS sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-N2PCH sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-AVSID sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FNAM1 sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FVAL1 sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FKOA1 sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FNAM2 sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FVAL2 sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FKOA2 sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FNAM3 sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FVAL3 sy-vline
WA_FEB_BSPROC_DETAIL_FE_STR-FKOA3 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.