ABAP Select data from SAP table FDT_CP_RULES_AIF_INBOUND_SRV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FDT_CP_RULES_AIF_INBOUND_SRV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FDT_CP_RULES_AIF_INBOUND_SRV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FDT_CP_RULES_AIF_INBOUND_SRV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FDT_CP_RULES_AIF_INBOUND_SRV TYPE STANDARD TABLE OF FDT_CP_RULES_AIF_INBOUND_SRV,
      WA_FDT_CP_RULES_AIF_INBOUND_SRV TYPE FDT_CP_RULES_AIF_INBOUND_SRV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FDT_CP_RULES_AIF_INBOUND_SRV> TYPE FDT_CP_RULES_AIF_INBOUND_SRV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FDT_CP_RULES_AIF_INBOUND_SRV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FDT_CP_RULES_AIF_INBOUND_SRV
  INTO TABLE IT_FDT_CP_RULES_AIF_INBOUND_SRV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FDT_CP_RULES_AIF_INBOUND_SRV
*  INTO TABLE @DATA(IT_FDT_CP_RULES_AIF_INBOUND_SRV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FDT_CP_RULES_AIF_INBOUND_SRV INDEX 1 INTO DATA(WA_FDT_CP_RULES_AIF_INBOUND_SRV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FDT_CP_RULES_AIF_INBOUND_SRV ASSIGNING <FDT_CP_RULES_AIF_INBOUND_SRV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FDT_CP_RULES_AIF_INBOUND_SRV>-ODATA_STD = 1.
<FDT_CP_RULES_AIF_INBOUND_SRV>-REQUEST_URI = 1.
<FDT_CP_RULES_AIF_INBOUND_SRV>-CRUD = 1.
<FDT_CP_RULES_AIF_INBOUND_SRV>-USERNAME = 1.
<FDT_CP_RULES_AIF_INBOUND_SRV>-TIMESTAMP = 1.
ENDLOOP.

LOOP AT IT_FDT_CP_RULES_AIF_INBOUND_SRV INTO WA_FDT_CP_RULES_AIF_INBOUND_SRV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FDT_CP_RULES_AIF_INBOUND_SRV-LOCATION, sy-vline,
WA_FDT_CP_RULES_AIF_INBOUND_SRV-CHANNEL, sy-vline,
WA_FDT_CP_RULES_AIF_INBOUND_SRV-NAMESPACE, sy-vline,
WA_FDT_CP_RULES_AIF_INBOUND_SRV-SERVICE_NAME, sy-vline,
WA_FDT_CP_RULES_AIF_INBOUND_SRV-REMOTE_ADDRESS, sy-vline,
WA_FDT_CP_RULES_AIF_INBOUND_SRV-DESTINATION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FDT_CP_RULES_AIF_INBOUND_SRV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FDT_CP_RULES_AIF_INBOUND_SRV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FDT_CP_RULES_AIF_INBOUND_SRV INTO WA_FDT_CP_RULES_AIF_INBOUND_SRV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FDT_CP_RULES_AIF_INBOUND_SRV_STR,
ODATA_STD TYPE STRING,
REQUEST_URI TYPE STRING,
CRUD TYPE STRING,
USERNAME TYPE STRING,
TIMESTAMP TYPE STRING,
LOCATION TYPE STRING,
CHANNEL TYPE STRING,
NAMESPACE TYPE STRING,
SERVICE_NAME TYPE STRING,
REMOTE_ADDRESS TYPE STRING,
DESTINATION TYPE STRING,
BALOGNO TYPE STRING,
ICF_NODE TYPE STRING,
REQUEST_ID TYPE STRING,
SERVICE_VERSION TYPE STRING,
RULES_DATA TYPE STRING,
RULE_SERVICE_ID TYPE STRING,
CONTENT_VERSION TYPE STRING,
CONTENT TYPE STRING,END OF T_EKKO_STR. DATA: WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-ODATA_STD sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-REQUEST_URI sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-CRUD sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-USERNAME sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-TIMESTAMP sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-LOCATION sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-CHANNEL sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-NAMESPACE sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-SERVICE_NAME sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-REMOTE_ADDRESS sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-DESTINATION sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-BALOGNO sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-ICF_NODE sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-REQUEST_ID sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-SERVICE_VERSION sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-RULES_DATA sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-RULE_SERVICE_ID sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-CONTENT_VERSION sy-vline
WA_FDT_CP_RULES_AIF_INBOUND_SRV_STR-CONTENT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.