ABAP Select data from SAP table FDC_S_ACCDOC_HDR_EXO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FDC_S_ACCDOC_HDR_EXO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FDC_S_ACCDOC_HDR_EXO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FDC_S_ACCDOC_HDR_EXO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FDC_S_ACCDOC_HDR_EXO TYPE STANDARD TABLE OF FDC_S_ACCDOC_HDR_EXO,
      WA_FDC_S_ACCDOC_HDR_EXO TYPE FDC_S_ACCDOC_HDR_EXO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FDC_S_ACCDOC_HDR_EXO> TYPE FDC_S_ACCDOC_HDR_EXO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FDC_S_ACCDOC_HDR_EXO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FDC_S_ACCDOC_HDR_EXO
  INTO TABLE IT_FDC_S_ACCDOC_HDR_EXO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FDC_S_ACCDOC_HDR_EXO
*  INTO TABLE @DATA(IT_FDC_S_ACCDOC_HDR_EXO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FDC_S_ACCDOC_HDR_EXO INDEX 1 INTO DATA(WA_FDC_S_ACCDOC_HDR_EXO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FDC_S_ACCDOC_HDR_EXO ASSIGNING <FDC_S_ACCDOC_HDR_EXO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FDC_S_ACCDOC_HDR_EXO>-BUKRS_TXT = 1.
<FDC_S_ACCDOC_HDR_EXO>-BLART_TXT = 1.
<FDC_S_ACCDOC_HDR_EXO>-LDGRP_TXT = 1.
<FDC_S_ACCDOC_HDR_EXO>-BSTAT_TXT = 1.
<FDC_S_ACCDOC_HDR_EXO>-GJAHR = 1.
ENDLOOP.

LOOP AT IT_FDC_S_ACCDOC_HDR_EXO INTO WA_FDC_S_ACCDOC_HDR_EXO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FDC_S_ACCDOC_HDR_EXO-HWAER, sy-vline,
WA_FDC_S_ACCDOC_HDR_EXO-HWAE2, sy-vline,
WA_FDC_S_ACCDOC_HDR_EXO-HWAE3, sy-vline,
WA_FDC_S_ACCDOC_HDR_EXO-HWAE4, sy-vline,
WA_FDC_S_ACCDOC_HDR_EXO-HWAE5, sy-vline,
WA_FDC_S_ACCDOC_HDR_EXO-HWAE6, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FDC_S_ACCDOC_HDR_EXO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FDC_S_ACCDOC_HDR_EXO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FDC_S_ACCDOC_HDR_EXO INTO WA_FDC_S_ACCDOC_HDR_EXO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FDC_S_ACCDOC_HDR_EXO-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDC_S_ACCDOC_HDR_EXO-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURS2 CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_FDC_S_ACCDOC_HDR_EXO-KURS2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDC_S_ACCDOC_HDR_EXO-KURS2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURS3 CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_FDC_S_ACCDOC_HDR_EXO-KURS3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDC_S_ACCDOC_HDR_EXO-KURS3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FDC_S_ACCDOC_HDR_EXO-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDC_S_ACCDOC_HDR_EXO-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DBBLG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FDC_S_ACCDOC_HDR_EXO-DBBLG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDC_S_ACCDOC_HDR_EXO-DBBLG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field DBBLG_GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FDC_S_ACCDOC_HDR_EXO-DBBLG_GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDC_S_ACCDOC_HDR_EXO-DBBLG_GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TEMPD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FDC_S_ACCDOC_HDR_EXO-TEMPD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDC_S_ACCDOC_HDR_EXO-TEMPD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FDC_S_ACCDOC_HDR_EXO_STR,
BUKRS_TXT TYPE STRING,
BLART_TXT TYPE STRING,
LDGRP_TXT TYPE STRING,
BSTAT_TXT TYPE STRING,
GJAHR TYPE STRING,
HWAER TYPE STRING,
HWAE2 TYPE STRING,
HWAE3 TYPE STRING,
HWAE4 TYPE STRING,
HWAE5 TYPE STRING,
HWAE6 TYPE STRING,
HWAE7 TYPE STRING,
HWAE8 TYPE STRING,
HWAE9 TYPE STRING,
HWAE10 TYPE STRING,
KURS2 TYPE STRING,
KURS3 TYPE STRING,
UMRD2 TYPE STRING,
UMRD3 TYPE STRING,
BASW2 TYPE STRING,
BASW3 TYPE STRING,
CURT1 TYPE STRING,
CURT2 TYPE STRING,
CURT3 TYPE STRING,
KURST TYPE STRING,
KUTY2 TYPE STRING,
KUTY3 TYPE STRING,
STBUK TYPE STRING,
CURT4 TYPE STRING,
CURT5 TYPE STRING,
CURT6 TYPE STRING,
CURT7 TYPE STRING,
CURT8 TYPE STRING,
CURT9 TYPE STRING,
CURT10 TYPE STRING,
CURT1_TXT TYPE STRING,
CURT2_TXT TYPE STRING,
CURT3_TXT TYPE STRING,
CURT4_TXT TYPE STRING,
CURT5_TXT TYPE STRING,
CURT6_TXT TYPE STRING,
CURT7_TXT TYPE STRING,
CURT8_TXT TYPE STRING,
CURT9_TXT TYPE STRING,
CURT10_TXT TYPE STRING,
RLDNR TYPE STRING,
RFCCUR TYPE STRING,
TCODE TYPE STRING,
LCHG_DATE_TIME TYPE STRING,
CRDAT TYPE STRING,
CRTIM TYPE STRING,
BSTAT TYPE STRING,
DISP_CURR TYPE STRING,
SCVARIANT TYPE STRING,
AUGLV TYPE STRING,
XREBZ TYPE STRING,
XNETA TYPE STRING,
XNOBK TYPE STRING,
XLGCLR TYPE STRING,
IS_CHANGE_ALLOWED TYPE STRING,
IS_OSP_WO_REF TYPE STRING,
DBBLG TYPE STRING,
DBBLG_GJAHR TYPE STRING,
DBBLG_BUKRS TYPE STRING,
STATUS_OLD TYPE STRING,
PPNAM TYPE STRING,
USNAM TYPE STRING,
USNAM_TXT TYPE STRING,
CPUDT TYPE STRING,
CPUTM TYPE STRING,
APPLICATION_ID TYPE STRING,
HOLD_DOC_UUID TYPE STRING,
HOLD_DOC_ID TYPE STRING,
HOLD_DOC_CRDAT TYPE STRING,
TEMPD TYPE STRING,
GLO_REF1_HD_LBL TYPE STRING,
GLO_DAT1_HD_LBL TYPE STRING,
GLO_REF2_HD_LBL TYPE STRING,
GLO_DAT2_HD_LBL TYPE STRING,
GLO_REF3_HD_LBL TYPE STRING,
GLO_DAT3_HD_LBL TYPE STRING,
GLO_REF4_HD_LBL TYPE STRING,
GLO_DAT4_HD_LBL TYPE STRING,
GLO_REF5_HD_LBL TYPE STRING,
GLO_DAT5_HD_LBL TYPE STRING,
GLO_BP1_HD_LBL TYPE STRING,
GLO_BP2_HD_LBL TYPE STRING,
XDISPUTE_ACTIVE TYPE STRING,
XCOLLECTION_ACTIVE TYPE STRING,
CASE_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FDC_S_ACCDOC_HDR_EXO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-BUKRS_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-BLART_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-LDGRP_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-BSTAT_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GJAHR sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HWAER sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HWAE2 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HWAE3 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HWAE4 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HWAE5 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HWAE6 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HWAE7 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HWAE8 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HWAE9 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HWAE10 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-KURS2 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-KURS3 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-UMRD2 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-UMRD3 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-BASW2 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-BASW3 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT1 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT2 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT3 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-KURST sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-KUTY2 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-KUTY3 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-STBUK sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT4 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT5 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT6 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT7 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT8 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT9 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT10 sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT1_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT2_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT3_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT4_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT5_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT6_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT7_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT8_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT9_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CURT10_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-RLDNR sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-RFCCUR sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-TCODE sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-LCHG_DATE_TIME sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CRDAT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CRTIM sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-BSTAT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-DISP_CURR sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-SCVARIANT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-AUGLV sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-XREBZ sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-XNETA sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-XNOBK sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-XLGCLR sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-IS_CHANGE_ALLOWED sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-IS_OSP_WO_REF sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-DBBLG sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-DBBLG_GJAHR sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-DBBLG_BUKRS sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-STATUS_OLD sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-PPNAM sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-USNAM sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-USNAM_TXT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CPUDT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CPUTM sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-APPLICATION_ID sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HOLD_DOC_UUID sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HOLD_DOC_ID sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-HOLD_DOC_CRDAT sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-TEMPD sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_REF1_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_DAT1_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_REF2_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_DAT2_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_REF3_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_DAT3_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_REF4_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_DAT4_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_REF5_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_DAT5_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_BP1_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-GLO_BP2_HD_LBL sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-XDISPUTE_ACTIVE sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-XCOLLECTION_ACTIVE sy-vline
WA_FDC_S_ACCDOC_HDR_EXO_STR-CASE_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.