ABAP Select data from SAP table FCOM_EXP_ACTQTY_WD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FCOM_EXP_ACTQTY_WD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FCOM_EXP_ACTQTY_WD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FCOM_EXP_ACTQTY_WD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FCOM_EXP_ACTQTY_WD TYPE STANDARD TABLE OF FCOM_EXP_ACTQTY_WD,
      WA_FCOM_EXP_ACTQTY_WD TYPE FCOM_EXP_ACTQTY_WD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FCOM_EXP_ACTQTY_WD> TYPE FCOM_EXP_ACTQTY_WD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FCOM_EXP_ACTQTY_WD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FCOM_EXP_ACTQTY_WD
  INTO TABLE IT_FCOM_EXP_ACTQTY_WD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FCOM_EXP_ACTQTY_WD
*  INTO TABLE @DATA(IT_FCOM_EXP_ACTQTY_WD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FCOM_EXP_ACTQTY_WD INDEX 1 INTO DATA(WA_FCOM_EXP_ACTQTY_WD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FCOM_EXP_ACTQTY_WD ASSIGNING <FCOM_EXP_ACTQTY_WD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FCOM_EXP_ACTQTY_WD>-OBJECT = 1.
<FCOM_EXP_ACTQTY_WD>-KOSTL = 1.
<FCOM_EXP_ACTQTY_WD>-KOSTL_ALPHA = 1.
<FCOM_EXP_ACTQTY_WD>-KOSTLTEXT = 1.
<FCOM_EXP_ACTQTY_WD>-KOSTL_DISP = 1.
ENDLOOP.

LOOP AT IT_FCOM_EXP_ACTQTY_WD INTO WA_FCOM_EXP_ACTQTY_WD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FCOM_EXP_ACTQTY_WD-LSTAR, sy-vline,
WA_FCOM_EXP_ACTQTY_WD-LSTAR_TEXT, sy-vline,
WA_FCOM_EXP_ACTQTY_WD-GJAHR, sy-vline,
WA_FCOM_EXP_ACTQTY_WD-WRTTP, sy-vline,
WA_FCOM_EXP_ACTQTY_WD-VERSN, sy-vline,
WA_FCOM_EXP_ACTQTY_WD-LEINH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FCOM_EXP_ACTQTY_WD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FCOM_EXP_ACTQTY_WD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FCOM_EXP_ACTQTY_WD INTO WA_FCOM_EXP_ACTQTY_WD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FCOM_EXP_ACTQTY_WD-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOM_EXP_ACTQTY_WD-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WRTTP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCOM_EXP_ACTQTY_WD-WRTTP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOM_EXP_ACTQTY_WD-WRTTP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCOM_EXP_ACTQTY_WD-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOM_EXP_ACTQTY_WD-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FCOM_EXP_ACTQTY_WD-LEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOM_EXP_ACTQTY_WD-LEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TARKZ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCOM_EXP_ACTQTY_WD-TARKZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOM_EXP_ACTQTY_WD-TARKZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKSTA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCOM_EXP_ACTQTY_WD-VKSTA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOM_EXP_ACTQTY_WD-VKSTA.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FCOM_EXP_ACTQTY_WD_STR,
OBJECT TYPE STRING,
KOSTL TYPE STRING,
KOSTL_ALPHA TYPE STRING,
KOSTLTEXT TYPE STRING,
KOSTL_DISP TYPE STRING,
LSTAR TYPE STRING,
LSTAR_TEXT TYPE STRING,
GJAHR TYPE STRING,
WRTTP TYPE STRING,
VERSN TYPE STRING,
LEINH TYPE STRING,
TKE TYPE STRING,
TARKZ TYPE STRING,
VKSTA TYPE STRING,
DIS_PER01 TYPE STRING,
DIS_PER02 TYPE STRING,
DIS_PER03 TYPE STRING,
DIS_PER04 TYPE STRING,
DIS_PER05 TYPE STRING,
DIS_PER06 TYPE STRING,
DIS_PER07 TYPE STRING,
DIS_PER08 TYPE STRING,
DIS_PER09 TYPE STRING,
DIS_PER10 TYPE STRING,
DIS_PER11 TYPE STRING,
DIS_PER12 TYPE STRING,
DIS_PER13 TYPE STRING,
DIS_PER14 TYPE STRING,
DIS_PER15 TYPE STRING,
DIS_PER16 TYPE STRING,
DIS_QUAR1 TYPE STRING,
DIS_QUAR2 TYPE STRING,
DIS_QUAR3 TYPE STRING,
DIS_QUAR4 TYPE STRING,
DIS_YEAR TYPE STRING,
KAP_REF1_PER01 TYPE STRING,
KAP_REF1_PER02 TYPE STRING,
KAP_REF1_PER03 TYPE STRING,
KAP_REF1_PER04 TYPE STRING,
KAP_REF1_PER05 TYPE STRING,
KAP_REF1_PER06 TYPE STRING,
KAP_REF1_PER07 TYPE STRING,
KAP_REF1_PER08 TYPE STRING,
KAP_REF1_PER09 TYPE STRING,
KAP_REF1_PER10 TYPE STRING,
KAP_REF1_PER11 TYPE STRING,
KAP_REF1_PER12 TYPE STRING,
KAP_REF1_PER13 TYPE STRING,
KAP_REF1_PER14 TYPE STRING,
KAP_REF1_PER15 TYPE STRING,
KAP_REF1_PER16 TYPE STRING,
KAP_REF1_QUAR1 TYPE STRING,
KAP_REF1_QUAR2 TYPE STRING,
KAP_REF1_QUAR3 TYPE STRING,
KAP_REF1_QUAR4 TYPE STRING,
KAP_REF1_YEAR TYPE STRING,
KAP_PLAN_PER01 TYPE STRING,
KAP_PLAN_PER02 TYPE STRING,
KAP_PLAN_PER03 TYPE STRING,
KAP_PLAN_PER04 TYPE STRING,
KAP_PLAN_PER05 TYPE STRING,
KAP_PLAN_PER06 TYPE STRING,
KAP_PLAN_PER07 TYPE STRING,
KAP_PLAN_PER08 TYPE STRING,
KAP_PLAN_PER09 TYPE STRING,
KAP_PLAN_PER10 TYPE STRING,
KAP_PLAN_PER11 TYPE STRING,
KAP_PLAN_PER12 TYPE STRING,
KAP_PLAN_PER13 TYPE STRING,
KAP_PLAN_PER14 TYPE STRING,
KAP_PLAN_PER15 TYPE STRING,
KAP_PLAN_PER16 TYPE STRING,
KAP_PLAN_QUAR1 TYPE STRING,
KAP_PLAN_QUAR2 TYPE STRING,
KAP_PLAN_QUAR3 TYPE STRING,
KAP_PLAN_QUAR4 TYPE STRING,
KAP_PLAN_YEAR TYPE STRING,
LST_REF1_PER01 TYPE STRING,
LST_REF1_PER02 TYPE STRING,
LST_REF1_PER03 TYPE STRING,
LST_REF1_PER04 TYPE STRING,
LST_REF1_PER05 TYPE STRING,
LST_REF1_PER06 TYPE STRING,
LST_REF1_PER07 TYPE STRING,
LST_REF1_PER08 TYPE STRING,
LST_REF1_PER09 TYPE STRING,
LST_REF1_PER10 TYPE STRING,
LST_REF1_PER11 TYPE STRING,
LST_REF1_PER12 TYPE STRING,
LST_REF1_PER13 TYPE STRING,
LST_REF1_PER14 TYPE STRING,
LST_REF1_PER15 TYPE STRING,
LST_REF1_PER16 TYPE STRING,
LST_REF1_QUAR1 TYPE STRING,
LST_REF1_QUAR2 TYPE STRING,
LST_REF1_QUAR3 TYPE STRING,
LST_REF1_QUAR4 TYPE STRING,
LST_REF1_YEAR TYPE STRING,
LST_PLAN_PER01 TYPE STRING,
LST_PLAN_PER02 TYPE STRING,
LST_PLAN_PER03 TYPE STRING,
LST_PLAN_PER04 TYPE STRING,
LST_PLAN_PER05 TYPE STRING,
LST_PLAN_PER06 TYPE STRING,
LST_PLAN_PER07 TYPE STRING,
LST_PLAN_PER08 TYPE STRING,
LST_PLAN_PER09 TYPE STRING,
LST_PLAN_PER10 TYPE STRING,
LST_PLAN_PER11 TYPE STRING,
LST_PLAN_PER12 TYPE STRING,
LST_PLAN_PER13 TYPE STRING,
LST_PLAN_PER14 TYPE STRING,
LST_PLAN_PER15 TYPE STRING,
LST_PLAN_PER16 TYPE STRING,
LST_PLAN_QUAR1 TYPE STRING,
LST_PLAN_QUAR2 TYPE STRING,
LST_PLAN_QUAR3 TYPE STRING,
LST_PLAN_QUAR4 TYPE STRING,
LST_PLAN_YEAR TYPE STRING,
COMMENT_ICON TYPE STRING,
COMMENT_ICON_TTP TYPE STRING,
PERIOD_CHANGED TYPE STRING,
BOOLE TYPE STRING,
FRONTEND_ADD TYPE STRING,
BOOLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FCOM_EXP_ACTQTY_WD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-OBJECT sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KOSTL sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KOSTL_ALPHA sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KOSTLTEXT sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KOSTL_DISP sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LSTAR sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LSTAR_TEXT sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-GJAHR sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-WRTTP sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-VERSN sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LEINH sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-TKE sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-TARKZ sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-VKSTA sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER01 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER02 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER03 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER04 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER05 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER06 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER07 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER08 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER09 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER10 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER11 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER12 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER13 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER14 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER15 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_PER16 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_QUAR1 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_QUAR2 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_QUAR3 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_QUAR4 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-DIS_YEAR sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER01 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER02 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER03 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER04 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER05 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER06 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER07 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER08 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER09 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER10 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER11 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER12 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER13 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER14 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER15 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_PER16 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_QUAR1 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_QUAR2 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_QUAR3 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_QUAR4 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_REF1_YEAR sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER01 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER02 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER03 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER04 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER05 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER06 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER07 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER08 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER09 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER10 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER11 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER12 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER13 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER14 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER15 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_PER16 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_QUAR1 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_QUAR2 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_QUAR3 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_QUAR4 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-KAP_PLAN_YEAR sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER01 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER02 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER03 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER04 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER05 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER06 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER07 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER08 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER09 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER10 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER11 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER12 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER13 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER14 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER15 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_PER16 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_QUAR1 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_QUAR2 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_QUAR3 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_QUAR4 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_REF1_YEAR sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER01 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER02 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER03 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER04 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER05 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER06 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER07 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER08 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER09 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER10 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER11 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER12 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER13 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER14 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER15 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_PER16 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_QUAR1 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_QUAR2 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_QUAR3 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_QUAR4 sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-LST_PLAN_YEAR sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-COMMENT_ICON sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-COMMENT_ICON_TTP sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-PERIOD_CHANGED sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-BOOLE sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-FRONTEND_ADD sy-vline
WA_FCOM_EXP_ACTQTY_WD_STR-BOOLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.