ABAP Select data from SAP table FCO_REWORK_COCKPIT_REWORK_EXT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FCO_REWORK_COCKPIT_REWORK_EXT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FCO_REWORK_COCKPIT_REWORK_EXT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FCO_REWORK_COCKPIT_REWORK_EXT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FCO_REWORK_COCKPIT_REWORK_EXT TYPE STANDARD TABLE OF FCO_REWORK_COCKPIT_REWORK_EXT,
      WA_FCO_REWORK_COCKPIT_REWORK_EXT TYPE FCO_REWORK_COCKPIT_REWORK_EXT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FCO_REWORK_COCKPIT_REWORK_EXT> TYPE FCO_REWORK_COCKPIT_REWORK_EXT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FCO_REWORK_COCKPIT_REWORK_EXT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FCO_REWORK_COCKPIT_REWORK_EXT
  INTO TABLE IT_FCO_REWORK_COCKPIT_REWORK_EXT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FCO_REWORK_COCKPIT_REWORK_EXT
*  INTO TABLE @DATA(IT_FCO_REWORK_COCKPIT_REWORK_EXT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FCO_REWORK_COCKPIT_REWORK_EXT INDEX 1 INTO DATA(WA_FCO_REWORK_COCKPIT_REWORK_EXT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FCO_REWORK_COCKPIT_REWORK_EXT ASSIGNING <FCO_REWORK_COCKPIT_REWORK_EXT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FCO_REWORK_COCKPIT_REWORK_EXT>-CHECKBOX = 1.
<FCO_REWORK_COCKPIT_REWORK_EXT>-AUTOWE = 1.
<FCO_REWORK_COCKPIT_REWORK_EXT>-OBJID = 1.
<FCO_REWORK_COCKPIT_REWORK_EXT>-AUFNR = 1.
<FCO_REWORK_COCKPIT_REWORK_EXT>-AUFNR_PKOSA = 1.
ENDLOOP.

LOOP AT IT_FCO_REWORK_COCKPIT_REWORK_EXT INTO WA_FCO_REWORK_COCKPIT_REWORK_EXT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FCO_REWORK_COCKPIT_REWORK_EXT-BUDAT, sy-vline,
WA_FCO_REWORK_COCKPIT_REWORK_EXT-AUFPL, sy-vline,
WA_FCO_REWORK_COCKPIT_REWORK_EXT-APLZL, sy-vline,
WA_FCO_REWORK_COCKPIT_REWORK_EXT-VORNE, sy-vline,
WA_FCO_REWORK_COCKPIT_REWORK_EXT-PLNFL, sy-vline,
WA_FCO_REWORK_COCKPIT_REWORK_EXT-RUECK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FCO_REWORK_COCKPIT_REWORK_EXT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FCO_REWORK_COCKPIT_REWORK_EXT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FCO_REWORK_COCKPIT_REWORK_EXT INTO WA_FCO_REWORK_COCKPIT_REWORK_EXT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR_PKOSA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-AUFNR_PKOSA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-AUFNR_PKOSA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNE CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-VORNE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-VORNE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-PLNFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-PLNFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-MEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RESPCC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-RESPCC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-RESPCC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NOTIF_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-NOTIF_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-NOTIF_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field REVLV CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-REVLV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-REVLV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR_IO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-AUFNR_IO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-AUFNR_IO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR_PP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-AUFNR_PP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-AUFNR_PP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field WBS_ELEMENT CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-WBS_ELEMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-WBS_ELEMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CALC_MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FCO_REWORK_COCKPIT_REWORK_EXT-CALC_MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCO_REWORK_COCKPIT_REWORK_EXT-CALC_MEINH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FCO_REWORK_COCKPIT_REWORK_EXT_STR,
CHECKBOX TYPE STRING,
AUTOWE TYPE STRING,
OBJID TYPE STRING,
AUFNR TYPE STRING,
AUFNR_PKOSA TYPE STRING,
BUDAT TYPE STRING,
AUFPL TYPE STRING,
APLZL TYPE STRING,
VORNE TYPE STRING,
PLNFL TYPE STRING,
RUECK TYPE STRING,
RMZHL TYPE STRING,
RQUANT TYPE STRING,
MEINH TYPE STRING,
RESPCC TYPE STRING,
NGRND TYPE STRING,
BELNR TYPE STRING,
REWORK_COMPL TYPE STRING,
BASISQUANT TYPE STRING,
MEINS TYPE STRING,
NOTIF_NUMBER TYPE STRING,
BWTAR TYPE STRING,
REVLV TYPE STRING,
AUFNR_IO TYPE STRING,
AUFNR_PP TYPE STRING,
WBS_ELEMENT TYPE STRING,
BWART TYPE STRING,
REW_OBJNR TYPE STRING,
CALC_QUANT TYPE STRING,
CALC_MEINH TYPE STRING,END OF T_EKKO_STR. DATA: WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-CHECKBOX sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-AUTOWE sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-OBJID sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-AUFNR sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-AUFNR_PKOSA sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-BUDAT sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-AUFPL sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-APLZL sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-VORNE sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-PLNFL sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-RUECK sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-RMZHL sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-RQUANT sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-MEINH sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-RESPCC sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-NGRND sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-BELNR sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-REWORK_COMPL sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-BASISQUANT sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-MEINS sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-NOTIF_NUMBER sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-BWTAR sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-REVLV sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-AUFNR_IO sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-AUFNR_PP sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-WBS_ELEMENT sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-BWART sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-REW_OBJNR sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-CALC_QUANT sy-vline
WA_FCO_REWORK_COCKPIT_REWORK_EXT_STR-CALC_MEINH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.