ABAP Select data from SAP table FCINDELRUDOC00_HLP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FCINDELRUDOC00_HLP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FCINDELRUDOC00_HLP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FCINDELRUDOC00_HLP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FCINDELRUDOC00_HLP TYPE STANDARD TABLE OF FCINDELRUDOC00_HLP,
      WA_FCINDELRUDOC00_HLP TYPE FCINDELRUDOC00_HLP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FCINDELRUDOC00_HLP> TYPE FCINDELRUDOC00_HLP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FCINDELRUDOC00_HLP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FCINDELRUDOC00_HLP
  INTO TABLE IT_FCINDELRUDOC00_HLP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FCINDELRUDOC00_HLP
*  INTO TABLE @DATA(IT_FCINDELRUDOC00_HLP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FCINDELRUDOC00_HLP INDEX 1 INTO DATA(WA_FCINDELRUDOC00_HLP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FCINDELRUDOC00_HLP ASSIGNING <FCINDELRUDOC00_HLP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FCINDELRUDOC00_HLP>-MANDT = 1.
<FCINDELRUDOC00_HLP>-CONTP = 1.
<FCINDELRUDOC00_HLP>-DIMEN = 1.
<FCINDELRUDOC00_HLP>-ITCLG = 1.
<FCINDELRUDOC00_HLP>-RVERS = 1.
ENDLOOP.

LOOP AT IT_FCINDELRUDOC00_HLP INTO WA_FCINDELRUDOC00_HLP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FCINDELRUDOC00_HLP-RYEAR, sy-vline,
WA_FCINDELRUDOC00_HLP-PERID, sy-vline,
WA_FCINDELRUDOC00_HLP-RYEAR_FROM, sy-vline,
WA_FCINDELRUDOC00_HLP-RYEAR_TO, sy-vline,
WA_FCINDELRUDOC00_HLP-PERID_FROM, sy-vline,
WA_FCINDELRUDOC00_HLP-PERID_TO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FCINDELRUDOC00_HLP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FCINDELRUDOC00_HLP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FCINDELRUDOC00_HLP INTO WA_FCINDELRUDOC00_HLP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR_FROM CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-RYEAR_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-RYEAR_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR_TO CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-RYEAR_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-RYEAR_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-DOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVSDOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-RVSDOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-RVSDOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORNDOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-ORNDOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-ORNDOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field REVYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-REVYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-REVYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field BUNIT CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-BUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-BUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field ITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-ITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-ITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field BUPTR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-BUPTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-BUPTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-TSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-TSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field HSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-HSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-HSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FCINDELRUDOC00_HLP-KSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCINDELRUDOC00_HLP-KSL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FCINDELRUDOC00_HLP_STR,
MANDT TYPE STRING,
CONTP TYPE STRING,
DIMEN TYPE STRING,
ITCLG TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
PERID TYPE STRING,
RYEAR_FROM TYPE STRING,
RYEAR_TO TYPE STRING,
PERID_FROM TYPE STRING,
PERID_TO TYPE STRING,
DOCNR TYPE STRING,
RLDNR TYPE STRING,
BUKRS TYPE STRING,
GLVOR TYPE STRING,
AWTYP TYPE STRING,
BLART TYPE STRING,
BELNR TYPE STRING,
BUDAT TYPE STRING,
CPUDT TYPE STRING,
TESTRUN TYPE STRING,
DOCTY TYPE STRING,
RVSDOCNR TYPE STRING,
ORNDOCNR TYPE STRING,
REVYEAR TYPE STRING,
REVPERID TYPE STRING,
GJAHR TYPE STRING,
MONAT TYPE STRING,
BUNIT TYPE STRING,
ITEM TYPE STRING,
SITYP TYPE STRING,
SUBIT TYPE STRING,
BUPTR TYPE STRING,
RTCUR TYPE STRING,
LCURR TYPE STRING,
GCURR TYPE STRING,
TSL TYPE STRING,
HSL TYPE STRING,
KSL TYPE STRING,END OF T_EKKO_STR. DATA: WA_FCINDELRUDOC00_HLP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FCINDELRUDOC00_HLP_STR-MANDT sy-vline
WA_FCINDELRUDOC00_HLP_STR-CONTP sy-vline
WA_FCINDELRUDOC00_HLP_STR-DIMEN sy-vline
WA_FCINDELRUDOC00_HLP_STR-ITCLG sy-vline
WA_FCINDELRUDOC00_HLP_STR-RVERS sy-vline
WA_FCINDELRUDOC00_HLP_STR-RYEAR sy-vline
WA_FCINDELRUDOC00_HLP_STR-PERID sy-vline
WA_FCINDELRUDOC00_HLP_STR-RYEAR_FROM sy-vline
WA_FCINDELRUDOC00_HLP_STR-RYEAR_TO sy-vline
WA_FCINDELRUDOC00_HLP_STR-PERID_FROM sy-vline
WA_FCINDELRUDOC00_HLP_STR-PERID_TO sy-vline
WA_FCINDELRUDOC00_HLP_STR-DOCNR sy-vline
WA_FCINDELRUDOC00_HLP_STR-RLDNR sy-vline
WA_FCINDELRUDOC00_HLP_STR-BUKRS sy-vline
WA_FCINDELRUDOC00_HLP_STR-GLVOR sy-vline
WA_FCINDELRUDOC00_HLP_STR-AWTYP sy-vline
WA_FCINDELRUDOC00_HLP_STR-BLART sy-vline
WA_FCINDELRUDOC00_HLP_STR-BELNR sy-vline
WA_FCINDELRUDOC00_HLP_STR-BUDAT sy-vline
WA_FCINDELRUDOC00_HLP_STR-CPUDT sy-vline
WA_FCINDELRUDOC00_HLP_STR-TESTRUN sy-vline
WA_FCINDELRUDOC00_HLP_STR-DOCTY sy-vline
WA_FCINDELRUDOC00_HLP_STR-RVSDOCNR sy-vline
WA_FCINDELRUDOC00_HLP_STR-ORNDOCNR sy-vline
WA_FCINDELRUDOC00_HLP_STR-REVYEAR sy-vline
WA_FCINDELRUDOC00_HLP_STR-REVPERID sy-vline
WA_FCINDELRUDOC00_HLP_STR-GJAHR sy-vline
WA_FCINDELRUDOC00_HLP_STR-MONAT sy-vline
WA_FCINDELRUDOC00_HLP_STR-BUNIT sy-vline
WA_FCINDELRUDOC00_HLP_STR-ITEM sy-vline
WA_FCINDELRUDOC00_HLP_STR-SITYP sy-vline
WA_FCINDELRUDOC00_HLP_STR-SUBIT sy-vline
WA_FCINDELRUDOC00_HLP_STR-BUPTR sy-vline
WA_FCINDELRUDOC00_HLP_STR-RTCUR sy-vline
WA_FCINDELRUDOC00_HLP_STR-LCURR sy-vline
WA_FCINDELRUDOC00_HLP_STR-GCURR sy-vline
WA_FCINDELRUDOC00_HLP_STR-TSL sy-vline
WA_FCINDELRUDOC00_HLP_STR-HSL sy-vline
WA_FCINDELRUDOC00_HLP_STR-KSL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.