ABAP Select data from SAP table FCCX_TASK_EXEC_M into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FCCX_TASK_EXEC_M table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FCCX_TASK_EXEC_M. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FCCX_TASK_EXEC_M table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FCCX_TASK_EXEC_M TYPE STANDARD TABLE OF FCCX_TASK_EXEC_M,
      WA_FCCX_TASK_EXEC_M TYPE FCCX_TASK_EXEC_M,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FCCX_TASK_EXEC_M> TYPE FCCX_TASK_EXEC_M.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FCCX_TASK_EXEC_M.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FCCX_TASK_EXEC_M
  INTO TABLE IT_FCCX_TASK_EXEC_M.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FCCX_TASK_EXEC_M
*  INTO TABLE @DATA(IT_FCCX_TASK_EXEC_M2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FCCX_TASK_EXEC_M INDEX 1 INTO DATA(WA_FCCX_TASK_EXEC_M2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FCCX_TASK_EXEC_M ASSIGNING <FCCX_TASK_EXEC_M>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FCCX_TASK_EXEC_M>-MANDT = 1.
<FCCX_TASK_EXEC_M>-MSGUUID = 1.
<FCCX_TASK_EXEC_M>-EXECUUID = 1.
<FCCX_TASK_EXEC_M>-RESULT_TYPE = 1.
<FCCX_TASK_EXEC_M>-RESULT_UUID = 1.
ENDLOOP.

LOOP AT IT_FCCX_TASK_EXEC_M INTO WA_FCCX_TASK_EXEC_M.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FCCX_TASK_EXEC_M-LOGNUMBER, sy-vline,
WA_FCCX_TASK_EXEC_M-OBJECT, sy-vline,
WA_FCCX_TASK_EXEC_M-SUBOBJECT, sy-vline,
WA_FCCX_TASK_EXEC_M-MSGTY, sy-vline,
WA_FCCX_TASK_EXEC_M-MSGID, sy-vline,
WA_FCCX_TASK_EXEC_M-MSGNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FCCX_TASK_EXEC_M you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FCCX_TASK_EXEC_M TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FCCX_TASK_EXEC_M INTO WA_FCCX_TASK_EXEC_M. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FCCX_TASK_EXEC_M_STR,
MANDT TYPE STRING,
MSGUUID TYPE STRING,
EXECUUID TYPE STRING,
RESULT_TYPE TYPE STRING,
RESULT_UUID TYPE STRING,
LOGNUMBER TYPE STRING,
OBJECT TYPE STRING,
SUBOBJECT TYPE STRING,
MSGTY TYPE STRING,
MSGID TYPE STRING,
MSGNO TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,
CREATED_ON TYPE STRING,
CREATED_BY TYPE STRING,
MESSAGE TYPE STRING,
BUKRS TYPE STRING,
KOKRS TYPE STRING,
WERKS TYPE STRING,
CGROP TYPE STRING,
CUNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_FCCX_TASK_EXEC_M_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FCCX_TASK_EXEC_M_STR-MANDT sy-vline
WA_FCCX_TASK_EXEC_M_STR-MSGUUID sy-vline
WA_FCCX_TASK_EXEC_M_STR-EXECUUID sy-vline
WA_FCCX_TASK_EXEC_M_STR-RESULT_TYPE sy-vline
WA_FCCX_TASK_EXEC_M_STR-RESULT_UUID sy-vline
WA_FCCX_TASK_EXEC_M_STR-LOGNUMBER sy-vline
WA_FCCX_TASK_EXEC_M_STR-OBJECT sy-vline
WA_FCCX_TASK_EXEC_M_STR-SUBOBJECT sy-vline
WA_FCCX_TASK_EXEC_M_STR-MSGTY sy-vline
WA_FCCX_TASK_EXEC_M_STR-MSGID sy-vline
WA_FCCX_TASK_EXEC_M_STR-MSGNO sy-vline
WA_FCCX_TASK_EXEC_M_STR-MSGV1 sy-vline
WA_FCCX_TASK_EXEC_M_STR-MSGV2 sy-vline
WA_FCCX_TASK_EXEC_M_STR-MSGV3 sy-vline
WA_FCCX_TASK_EXEC_M_STR-MSGV4 sy-vline
WA_FCCX_TASK_EXEC_M_STR-CREATED_ON sy-vline
WA_FCCX_TASK_EXEC_M_STR-CREATED_BY sy-vline
WA_FCCX_TASK_EXEC_M_STR-MESSAGE sy-vline
WA_FCCX_TASK_EXEC_M_STR-BUKRS sy-vline
WA_FCCX_TASK_EXEC_M_STR-KOKRS sy-vline
WA_FCCX_TASK_EXEC_M_STR-WERKS sy-vline
WA_FCCX_TASK_EXEC_M_STR-CGROP sy-vline
WA_FCCX_TASK_EXEC_M_STR-CUNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.