ABAP Select data from SAP table FCCX_TASK_EXEC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FCCX_TASK_EXEC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FCCX_TASK_EXEC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FCCX_TASK_EXEC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FCCX_TASK_EXEC TYPE STANDARD TABLE OF FCCX_TASK_EXEC,
      WA_FCCX_TASK_EXEC TYPE FCCX_TASK_EXEC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FCCX_TASK_EXEC> TYPE FCCX_TASK_EXEC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FCCX_TASK_EXEC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FCCX_TASK_EXEC
  INTO TABLE IT_FCCX_TASK_EXEC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FCCX_TASK_EXEC
*  INTO TABLE @DATA(IT_FCCX_TASK_EXEC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FCCX_TASK_EXEC INDEX 1 INTO DATA(WA_FCCX_TASK_EXEC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FCCX_TASK_EXEC ASSIGNING <FCCX_TASK_EXEC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FCCX_TASK_EXEC>-MANDT = 1.
<FCCX_TASK_EXEC>-OWN_SYSTEM_UUID = 1.
<FCCX_TASK_EXEC>-EXEC_GRP_UUID = 1.
<FCCX_TASK_EXEC>-EXECUUID = 1.
<FCCX_TASK_EXEC>-TASK_UUID = 1.
ENDLOOP.

LOOP AT IT_FCCX_TASK_EXEC INTO WA_FCCX_TASK_EXEC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FCCX_TASK_EXEC-BTC_JOB_NAME, sy-vline,
WA_FCCX_TASK_EXEC-BTC_JOB_ID, sy-vline,
WA_FCCX_TASK_EXEC-BTC_STEP_COUNT, sy-vline,
WA_FCCX_TASK_EXEC-LIFE_CYCLE_STATUS, sy-vline,
WA_FCCX_TASK_EXEC-CREATED_BY, sy-vline,
WA_FCCX_TASK_EXEC-CREATED_ON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FCCX_TASK_EXEC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FCCX_TASK_EXEC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FCCX_TASK_EXEC INTO WA_FCCX_TASK_EXEC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FCCX_TASK_EXEC_STR,
MANDT TYPE STRING,
OWN_SYSTEM_UUID TYPE STRING,
EXEC_GRP_UUID TYPE STRING,
EXECUUID TYPE STRING,
TASK_UUID TYPE STRING,
BTC_JOB_NAME TYPE STRING,
BTC_JOB_ID TYPE STRING,
BTC_STEP_COUNT TYPE STRING,
LIFE_CYCLE_STATUS TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
LAST_CHANGED_BY TYPE STRING,
LAST_CHANGED_ON TYPE STRING,
BTC_START_ON TYPE STRING,
BTC_END_ON TYPE STRING,
COMBINED_STATUS TYPE STRING,
BTC_PLANNED_START_ON TYPE STRING,
TASK TYPE STRING,
BTTYPE TYPE STRING,
PARAMETERS TYPE STRING,
BUKRS TYPE STRING,
KOKRS TYPE STRING,
WERKS TYPE STRING,
CGROP TYPE STRING,
CUNIT TYPE STRING,
COUNTRY TYPE STRING,END OF T_EKKO_STR. DATA: WA_FCCX_TASK_EXEC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FCCX_TASK_EXEC_STR-MANDT sy-vline
WA_FCCX_TASK_EXEC_STR-OWN_SYSTEM_UUID sy-vline
WA_FCCX_TASK_EXEC_STR-EXEC_GRP_UUID sy-vline
WA_FCCX_TASK_EXEC_STR-EXECUUID sy-vline
WA_FCCX_TASK_EXEC_STR-TASK_UUID sy-vline
WA_FCCX_TASK_EXEC_STR-BTC_JOB_NAME sy-vline
WA_FCCX_TASK_EXEC_STR-BTC_JOB_ID sy-vline
WA_FCCX_TASK_EXEC_STR-BTC_STEP_COUNT sy-vline
WA_FCCX_TASK_EXEC_STR-LIFE_CYCLE_STATUS sy-vline
WA_FCCX_TASK_EXEC_STR-CREATED_BY sy-vline
WA_FCCX_TASK_EXEC_STR-CREATED_ON sy-vline
WA_FCCX_TASK_EXEC_STR-LAST_CHANGED_BY sy-vline
WA_FCCX_TASK_EXEC_STR-LAST_CHANGED_ON sy-vline
WA_FCCX_TASK_EXEC_STR-BTC_START_ON sy-vline
WA_FCCX_TASK_EXEC_STR-BTC_END_ON sy-vline
WA_FCCX_TASK_EXEC_STR-COMBINED_STATUS sy-vline
WA_FCCX_TASK_EXEC_STR-BTC_PLANNED_START_ON sy-vline
WA_FCCX_TASK_EXEC_STR-TASK sy-vline
WA_FCCX_TASK_EXEC_STR-BTTYPE sy-vline
WA_FCCX_TASK_EXEC_STR-PARAMETERS sy-vline
WA_FCCX_TASK_EXEC_STR-BUKRS sy-vline
WA_FCCX_TASK_EXEC_STR-KOKRS sy-vline
WA_FCCX_TASK_EXEC_STR-WERKS sy-vline
WA_FCCX_TASK_EXEC_STR-CGROP sy-vline
WA_FCCX_TASK_EXEC_STR-CUNIT sy-vline
WA_FCCX_TASK_EXEC_STR-COUNTRY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.