ABAP Select data from SAP table FC05RCLDOCLN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FC05RCLDOCLN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FC05RCLDOCLN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FC05RCLDOCLN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FC05RCLDOCLN TYPE STANDARD TABLE OF FC05RCLDOCLN,
      WA_FC05RCLDOCLN TYPE FC05RCLDOCLN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FC05RCLDOCLN> TYPE FC05RCLDOCLN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FC05RCLDOCLN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FC05RCLDOCLN
  INTO TABLE IT_FC05RCLDOCLN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FC05RCLDOCLN
*  INTO TABLE @DATA(IT_FC05RCLDOCLN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FC05RCLDOCLN INDEX 1 INTO DATA(WA_FC05RCLDOCLN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FC05RCLDOCLN ASSIGNING <FC05RCLDOCLN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FC05RCLDOCLN>-DOCNR = 1.
<FC05RCLDOCLN>-DOCLN = 1.
<FC05RCLDOCLN>-AUTOM = 1.
<FC05RCLDOCLN>-RBUNIT = 1.
<FC05RCLDOCLN>-RHCUR = 1.
ENDLOOP.

LOOP AT IT_FC05RCLDOCLN INTO WA_FC05RCLDOCLN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FC05RCLDOCLN-RITEM, sy-vline,
WA_FC05RCLDOCLN-SITYP, sy-vline,
WA_FC05RCLDOCLN-SUBIT, sy-vline,
WA_FC05RCLDOCLN-RBUPTR, sy-vline,
WA_FC05RCLDOCLN-RTCUR, sy-vline,
WA_FC05RCLDOCLN-RUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FC05RCLDOCLN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FC05RCLDOCLN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FC05RCLDOCLN INTO WA_FC05RCLDOCLN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC05RCLDOCLN-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05RCLDOCLN-DOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RBUNIT CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC05RCLDOCLN-RBUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05RCLDOCLN-RBUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field RITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_FC05RCLDOCLN-RITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05RCLDOCLN-RITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RBUPTR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC05RCLDOCLN-RBUPTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05RCLDOCLN-RBUPTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FC05RCLDOCLN-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05RCLDOCLN-RUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field YRACQ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC05RCLDOCLN-YRACQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05RCLDOCLN-YRACQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC05RCLDOCLN-TSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05RCLDOCLN-TSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field HSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC05RCLDOCLN-HSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05RCLDOCLN-HSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC05RCLDOCLN-KSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05RCLDOCLN-KSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RCONGR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC05RCLDOCLN-RCONGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05RCLDOCLN-RCONGR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FC05RCLDOCLN_STR,
DOCNR TYPE STRING,
DOCLN TYPE STRING,
AUTOM TYPE STRING,
RBUNIT TYPE STRING,
RHCUR TYPE STRING,
RITEM TYPE STRING,
SITYP TYPE STRING,
SUBIT TYPE STRING,
RBUPTR TYPE STRING,
RTCUR TYPE STRING,
RUNIT TYPE STRING,
YRACQ TYPE STRING,
PRACQ TYPE STRING,
TSL TYPE STRING,
HSL TYPE STRING,
KSL TYPE STRING,
MSL TYPE STRING,
RPFLG TYPE STRING,
RCONGR TYPE STRING,END OF T_EKKO_STR. DATA: WA_FC05RCLDOCLN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FC05RCLDOCLN_STR-DOCNR sy-vline
WA_FC05RCLDOCLN_STR-DOCLN sy-vline
WA_FC05RCLDOCLN_STR-AUTOM sy-vline
WA_FC05RCLDOCLN_STR-RBUNIT sy-vline
WA_FC05RCLDOCLN_STR-RHCUR sy-vline
WA_FC05RCLDOCLN_STR-RITEM sy-vline
WA_FC05RCLDOCLN_STR-SITYP sy-vline
WA_FC05RCLDOCLN_STR-SUBIT sy-vline
WA_FC05RCLDOCLN_STR-RBUPTR sy-vline
WA_FC05RCLDOCLN_STR-RTCUR sy-vline
WA_FC05RCLDOCLN_STR-RUNIT sy-vline
WA_FC05RCLDOCLN_STR-YRACQ sy-vline
WA_FC05RCLDOCLN_STR-PRACQ sy-vline
WA_FC05RCLDOCLN_STR-TSL sy-vline
WA_FC05RCLDOCLN_STR-HSL sy-vline
WA_FC05RCLDOCLN_STR-KSL sy-vline
WA_FC05RCLDOCLN_STR-MSL sy-vline
WA_FC05RCLDOCLN_STR-RPFLG sy-vline
WA_FC05RCLDOCLN_STR-RCONGR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.