ABAP Select data from SAP table FC03VALTAB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FC03VALTAB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FC03VALTAB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FC03VALTAB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FC03VALTAB TYPE STANDARD TABLE OF FC03VALTAB,
      WA_FC03VALTAB TYPE FC03VALTAB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FC03VALTAB> TYPE FC03VALTAB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FC03VALTAB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FC03VALTAB
  INTO TABLE IT_FC03VALTAB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FC03VALTAB
*  INTO TABLE @DATA(IT_FC03VALTAB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FC03VALTAB INDEX 1 INTO DATA(WA_FC03VALTAB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FC03VALTAB ASSIGNING <FC03VALTAB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FC03VALTAB>-DIMEN = 1.
<FC03VALTAB>-RVERS = 1.
<FC03VALTAB>-RYEAR = 1.
<FC03VALTAB>-PERID = 1.
<FC03VALTAB>-CONGR = 1.
ENDLOOP.

LOOP AT IT_FC03VALTAB INTO WA_FC03VALTAB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FC03VALTAB-BUNIT, sy-vline,
WA_FC03VALTAB-VALID, sy-vline,
WA_FC03VALTAB-VAREA0, sy-vline,
WA_FC03VALTAB-VAREA1, sy-vline,
WA_FC03VALTAB-VAREA2, sy-vline,
WA_FC03VALTAB-VAREA3, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FC03VALTAB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FC03VALTAB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FC03VALTAB INTO WA_FC03VALTAB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC03VALTAB-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03VALTAB-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC03VALTAB-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03VALTAB-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field CONGR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC03VALTAB-CONGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03VALTAB-CONGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field BUNIT CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC03VALTAB-BUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03VALTAB-BUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FC03VALTAB_STR,
DIMEN TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
PERID TYPE STRING,
CONGR TYPE STRING,
BUNIT TYPE STRING,
VALID TYPE STRING,
VAREA0 TYPE STRING,
VAREA1 TYPE STRING,
VAREA2 TYPE STRING,
VAREA3 TYPE STRING,
VCURR1 TYPE STRING,
VCURR2 TYPE STRING,
VCURR3 TYPE STRING,
ITCLG TYPE STRING,
ROBUN TYPE STRING,
ROLEV TYPE STRING,
CORR_UJ TYPE STRING,
TESTRUN TYPE STRING,
PROT TYPE STRING,
LORIG TYPE STRING,END OF T_EKKO_STR. DATA: WA_FC03VALTAB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FC03VALTAB_STR-DIMEN sy-vline
WA_FC03VALTAB_STR-RVERS sy-vline
WA_FC03VALTAB_STR-RYEAR sy-vline
WA_FC03VALTAB_STR-PERID sy-vline
WA_FC03VALTAB_STR-CONGR sy-vline
WA_FC03VALTAB_STR-BUNIT sy-vline
WA_FC03VALTAB_STR-VALID sy-vline
WA_FC03VALTAB_STR-VAREA0 sy-vline
WA_FC03VALTAB_STR-VAREA1 sy-vline
WA_FC03VALTAB_STR-VAREA2 sy-vline
WA_FC03VALTAB_STR-VAREA3 sy-vline
WA_FC03VALTAB_STR-VCURR1 sy-vline
WA_FC03VALTAB_STR-VCURR2 sy-vline
WA_FC03VALTAB_STR-VCURR3 sy-vline
WA_FC03VALTAB_STR-ITCLG sy-vline
WA_FC03VALTAB_STR-ROBUN sy-vline
WA_FC03VALTAB_STR-ROLEV sy-vline
WA_FC03VALTAB_STR-CORR_UJ sy-vline
WA_FC03VALTAB_STR-TESTRUN sy-vline
WA_FC03VALTAB_STR-PROT sy-vline
WA_FC03VALTAB_STR-LORIG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.