ABAP Select data from SAP table FC03_S_UPL16 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FC03_S_UPL16 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FC03_S_UPL16. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FC03_S_UPL16 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FC03_S_UPL16 TYPE STANDARD TABLE OF FC03_S_UPL16,
      WA_FC03_S_UPL16 TYPE FC03_S_UPL16,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FC03_S_UPL16> TYPE FC03_S_UPL16.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FC03_S_UPL16.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FC03_S_UPL16
  INTO TABLE IT_FC03_S_UPL16.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FC03_S_UPL16
*  INTO TABLE @DATA(IT_FC03_S_UPL162).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FC03_S_UPL16 INDEX 1 INTO DATA(WA_FC03_S_UPL162).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FC03_S_UPL16 ASSIGNING <FC03_S_UPL16>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FC03_S_UPL16>-RITCLG = 1.
<FC03_S_UPL16>-RDIMEN = 1.
<FC03_S_UPL16>-RVERS = 1.
<FC03_S_UPL16>-RYEAR = 1.
<FC03_S_UPL16>-POPER = 1.
ENDLOOP.

LOOP AT IT_FC03_S_UPL16 INTO WA_FC03_S_UPL16.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FC03_S_UPL16-DOCTY, sy-vline,
WA_FC03_S_UPL16-RCONGR, sy-vline,
WA_FC03_S_UPL16-RBUNIT, sy-vline,
WA_FC03_S_UPL16-RITEM, sy-vline,
WA_FC03_S_UPL16-SITYP, sy-vline,
WA_FC03_S_UPL16-SUBIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FC03_S_UPL16 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FC03_S_UPL16 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FC03_S_UPL16 INTO WA_FC03_S_UPL16. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RCONGR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-RCONGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-RCONGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RBUNIT CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-RBUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-RBUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field RITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-RITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-RITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RBUPTR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-RBUPTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-RBUPTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field YRACQ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-YRACQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-YRACQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-RUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-KSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-KSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field HSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-HSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-HSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-TSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-TSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC03_S_UPL16-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL16-DOCNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FC03_S_UPL16_STR,
RITCLG TYPE STRING,
RDIMEN TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
POPER TYPE STRING,
DOCTY TYPE STRING,
RCONGR TYPE STRING,
RBUNIT TYPE STRING,
RITEM TYPE STRING,
SITYP TYPE STRING,
SUBIT TYPE STRING,
RBUPTR TYPE STRING,
YRACQ TYPE STRING,
PRACQ TYPE STRING,
RGCUR TYPE STRING,
RLCUR TYPE STRING,
RTCUR TYPE STRING,
RUNIT TYPE STRING,
KSL TYPE STRING,
HSL TYPE STRING,
TSL TYPE STRING,
MSL TYPE STRING,
RLDNR TYPE STRING,
DOCNR TYPE STRING,
DOCLN TYPE STRING,
LINECOUNT TYPE STRING,
LINETYPE TYPE STRING,
LINECOUNT_HEAD TYPE STRING,
PROT_ERR TYPE STRING,END OF T_EKKO_STR. DATA: WA_FC03_S_UPL16_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FC03_S_UPL16_STR-RITCLG sy-vline
WA_FC03_S_UPL16_STR-RDIMEN sy-vline
WA_FC03_S_UPL16_STR-RVERS sy-vline
WA_FC03_S_UPL16_STR-RYEAR sy-vline
WA_FC03_S_UPL16_STR-POPER sy-vline
WA_FC03_S_UPL16_STR-DOCTY sy-vline
WA_FC03_S_UPL16_STR-RCONGR sy-vline
WA_FC03_S_UPL16_STR-RBUNIT sy-vline
WA_FC03_S_UPL16_STR-RITEM sy-vline
WA_FC03_S_UPL16_STR-SITYP sy-vline
WA_FC03_S_UPL16_STR-SUBIT sy-vline
WA_FC03_S_UPL16_STR-RBUPTR sy-vline
WA_FC03_S_UPL16_STR-YRACQ sy-vline
WA_FC03_S_UPL16_STR-PRACQ sy-vline
WA_FC03_S_UPL16_STR-RGCUR sy-vline
WA_FC03_S_UPL16_STR-RLCUR sy-vline
WA_FC03_S_UPL16_STR-RTCUR sy-vline
WA_FC03_S_UPL16_STR-RUNIT sy-vline
WA_FC03_S_UPL16_STR-KSL sy-vline
WA_FC03_S_UPL16_STR-HSL sy-vline
WA_FC03_S_UPL16_STR-TSL sy-vline
WA_FC03_S_UPL16_STR-MSL sy-vline
WA_FC03_S_UPL16_STR-RLDNR sy-vline
WA_FC03_S_UPL16_STR-DOCNR sy-vline
WA_FC03_S_UPL16_STR-DOCLN sy-vline
WA_FC03_S_UPL16_STR-LINECOUNT sy-vline
WA_FC03_S_UPL16_STR-LINETYPE sy-vline
WA_FC03_S_UPL16_STR-LINECOUNT_HEAD sy-vline
WA_FC03_S_UPL16_STR-PROT_ERR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.