ABAP Select data from SAP table FC03_S_UPL06 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FC03_S_UPL06 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FC03_S_UPL06. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FC03_S_UPL06 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FC03_S_UPL06 TYPE STANDARD TABLE OF FC03_S_UPL06,
      WA_FC03_S_UPL06 TYPE FC03_S_UPL06,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FC03_S_UPL06> TYPE FC03_S_UPL06.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FC03_S_UPL06.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FC03_S_UPL06
  INTO TABLE IT_FC03_S_UPL06.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FC03_S_UPL06
*  INTO TABLE @DATA(IT_FC03_S_UPL062).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FC03_S_UPL06 INDEX 1 INTO DATA(WA_FC03_S_UPL062).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FC03_S_UPL06 ASSIGNING <FC03_S_UPL06>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FC03_S_UPL06>-SITYP = 1.
<FC03_S_UPL06>-SITEM = 1.
<FC03_S_UPL06>-LANGU = 1.
<FC03_S_UPL06>-SIGN = 1.
<FC03_S_UPL06>-UPCFO = 1.
ENDLOOP.

LOOP AT IT_FC03_S_UPL06 INTO WA_FC03_S_UPL06.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FC03_S_UPL06-FMLIND, sy-vline,
WA_FC03_S_UPL06-CFIND, sy-vline,
WA_FC03_S_UPL06-SDEIND, sy-vline,
WA_FC03_S_UPL06-CYIND, sy-vline,
WA_FC03_S_UPL06-UPRET, sy-vline,
WA_FC03_S_UPL06-UPACQ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FC03_S_UPL06 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FC03_S_UPL06 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FC03_S_UPL06 INTO WA_FC03_S_UPL06. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_FC03_S_UPL06-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_UPL06-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FC03_S_UPL06_STR,
SITYP TYPE STRING,
SITEM TYPE STRING,
LANGU TYPE STRING,
SIGN TYPE STRING,
UPCFO TYPE STRING,
FMLIND TYPE STRING,
CFIND TYPE STRING,
SDEIND TYPE STRING,
CYIND TYPE STRING,
UPRET TYPE STRING,
UPACQ TYPE STRING,
UPMER TYPE STRING,
TXTSH TYPE STRING,
TXTMI TYPE STRING,
TXTLG TYPE STRING,
DUMMY TYPE STRING,
SEQNR TYPE STRING,
LINECOUNT TYPE STRING,
LINETYPE TYPE STRING,
LINECOUNT_HEAD TYPE STRING,
PROT_ERR TYPE STRING,END OF T_EKKO_STR. DATA: WA_FC03_S_UPL06_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FC03_S_UPL06_STR-SITYP sy-vline
WA_FC03_S_UPL06_STR-SITEM sy-vline
WA_FC03_S_UPL06_STR-LANGU sy-vline
WA_FC03_S_UPL06_STR-SIGN sy-vline
WA_FC03_S_UPL06_STR-UPCFO sy-vline
WA_FC03_S_UPL06_STR-FMLIND sy-vline
WA_FC03_S_UPL06_STR-CFIND sy-vline
WA_FC03_S_UPL06_STR-SDEIND sy-vline
WA_FC03_S_UPL06_STR-CYIND sy-vline
WA_FC03_S_UPL06_STR-UPRET sy-vline
WA_FC03_S_UPL06_STR-UPACQ sy-vline
WA_FC03_S_UPL06_STR-UPMER sy-vline
WA_FC03_S_UPL06_STR-TXTSH sy-vline
WA_FC03_S_UPL06_STR-TXTMI sy-vline
WA_FC03_S_UPL06_STR-TXTLG sy-vline
WA_FC03_S_UPL06_STR-DUMMY sy-vline
WA_FC03_S_UPL06_STR-SEQNR sy-vline
WA_FC03_S_UPL06_STR-LINECOUNT sy-vline
WA_FC03_S_UPL06_STR-LINETYPE sy-vline
WA_FC03_S_UPL06_STR-LINECOUNT_HEAD sy-vline
WA_FC03_S_UPL06_STR-PROT_ERR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.