ABAP Select data from SAP table FC00LST10M into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FC00LST10M table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FC00LST10M. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FC00LST10M table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FC00LST10M TYPE STANDARD TABLE OF FC00LST10M,
      WA_FC00LST10M TYPE FC00LST10M,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FC00LST10M> TYPE FC00LST10M.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FC00LST10M.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FC00LST10M
  INTO TABLE IT_FC00LST10M.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FC00LST10M
*  INTO TABLE @DATA(IT_FC00LST10M2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FC00LST10M INDEX 1 INTO DATA(WA_FC00LST10M2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FC00LST10M ASSIGNING <FC00LST10M>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FC00LST10M>-POPER = 1.
<FC00LST10M>-DOCNR = 1.
<FC00LST10M>-DOCLN = 1.
<FC00LST10M>-SGTXT = 1.
<FC00LST10M>-DOCCT = 1.
ENDLOOP.

LOOP AT IT_FC00LST10M INTO WA_FC00LST10M.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FC00LST10M-DOCTY, sy-vline,
WA_FC00LST10M-PLEVL, sy-vline,
WA_FC00LST10M-RPFLG, sy-vline,
WA_FC00LST10M-RTFLG, sy-vline,
WA_FC00LST10M-AUTOM, sy-vline,
WA_FC00LST10M-RBUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FC00LST10M you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FC00LST10M TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FC00LST10M INTO WA_FC00LST10M. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC00LST10M-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-DOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RBUNIT CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC00LST10M-RBUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-RBUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field RITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_FC00LST10M-RITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-RITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RBUPTR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC00LST10M-RBUPTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-RBUPTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field YRACQ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC00LST10M-YRACQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-YRACQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RCONGR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC00LST10M-RCONGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-RCONGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field COICU CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC00LST10M-COICU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-COICU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COINR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC00LST10M-COINR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-COINR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVSDOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC00LST10M-RVSDOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-RVSDOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORNDOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC00LST10M-ORNDOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-ORNDOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field REVYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC00LST10M-REVYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-REVYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC00LST10M-TSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-TSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field HSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC00LST10M-HSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-HSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC00LST10M-KSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-KSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FC00LST10M-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-RUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFDOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC00LST10M-REFDOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-REFDOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field REFRYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC00LST10M-REFRYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-REFRYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC00LST10M-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00LST10M-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FC00LST10M_STR,
POPER TYPE STRING,
DOCNR TYPE STRING,
DOCLN TYPE STRING,
SGTXT TYPE STRING,
DOCCT TYPE STRING,
DOCTY TYPE STRING,
PLEVL TYPE STRING,
RPFLG TYPE STRING,
RTFLG TYPE STRING,
AUTOM TYPE STRING,
RBUNIT TYPE STRING,
RITCLG TYPE STRING,
RITEM TYPE STRING,
SITYP TYPE STRING,
SUBIT TYPE STRING,
RBUPTR TYPE STRING,
YRACQ TYPE STRING,
PRACQ TYPE STRING,
RCONGR TYPE STRING,
COICU TYPE STRING,
COIAC TYPE STRING,
COINR TYPE STRING,
RVSDOCNR TYPE STRING,
ORNDOCNR TYPE STRING,
REVYEAR TYPE STRING,
RTCUR TYPE STRING,
TSL TYPE STRING,
LCURR TYPE STRING,
HSL TYPE STRING,
GCURR TYPE STRING,
KSL TYPE STRING,
RUNIT TYPE STRING,
MSL TYPE STRING,
BUDAT TYPE STRING,
WSDAT TYPE STRING,
CPUDT TYPE STRING,
CPUTM TYPE STRING,
USNAM TYPE STRING,
ROBUKRS TYPE STRING,
ACTIV TYPE STRING,
BVORG TYPE STRING,
REFDOCNR TYPE STRING,
REFRYEAR TYPE STRING,
REFDOCLN TYPE STRING,
REFDOCCT TYPE STRING,
REFACTIV TYPE STRING,
AWTYP TYPE STRING,
AWORG TYPE STRING,
LOGSYS TYPE STRING,
UNIJRL TYPE STRING,END OF T_EKKO_STR. DATA: WA_FC00LST10M_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FC00LST10M_STR-POPER sy-vline
WA_FC00LST10M_STR-DOCNR sy-vline
WA_FC00LST10M_STR-DOCLN sy-vline
WA_FC00LST10M_STR-SGTXT sy-vline
WA_FC00LST10M_STR-DOCCT sy-vline
WA_FC00LST10M_STR-DOCTY sy-vline
WA_FC00LST10M_STR-PLEVL sy-vline
WA_FC00LST10M_STR-RPFLG sy-vline
WA_FC00LST10M_STR-RTFLG sy-vline
WA_FC00LST10M_STR-AUTOM sy-vline
WA_FC00LST10M_STR-RBUNIT sy-vline
WA_FC00LST10M_STR-RITCLG sy-vline
WA_FC00LST10M_STR-RITEM sy-vline
WA_FC00LST10M_STR-SITYP sy-vline
WA_FC00LST10M_STR-SUBIT sy-vline
WA_FC00LST10M_STR-RBUPTR sy-vline
WA_FC00LST10M_STR-YRACQ sy-vline
WA_FC00LST10M_STR-PRACQ sy-vline
WA_FC00LST10M_STR-RCONGR sy-vline
WA_FC00LST10M_STR-COICU sy-vline
WA_FC00LST10M_STR-COIAC sy-vline
WA_FC00LST10M_STR-COINR sy-vline
WA_FC00LST10M_STR-RVSDOCNR sy-vline
WA_FC00LST10M_STR-ORNDOCNR sy-vline
WA_FC00LST10M_STR-REVYEAR sy-vline
WA_FC00LST10M_STR-RTCUR sy-vline
WA_FC00LST10M_STR-TSL sy-vline
WA_FC00LST10M_STR-LCURR sy-vline
WA_FC00LST10M_STR-HSL sy-vline
WA_FC00LST10M_STR-GCURR sy-vline
WA_FC00LST10M_STR-KSL sy-vline
WA_FC00LST10M_STR-RUNIT sy-vline
WA_FC00LST10M_STR-MSL sy-vline
WA_FC00LST10M_STR-BUDAT sy-vline
WA_FC00LST10M_STR-WSDAT sy-vline
WA_FC00LST10M_STR-CPUDT sy-vline
WA_FC00LST10M_STR-CPUTM sy-vline
WA_FC00LST10M_STR-USNAM sy-vline
WA_FC00LST10M_STR-ROBUKRS sy-vline
WA_FC00LST10M_STR-ACTIV sy-vline
WA_FC00LST10M_STR-BVORG sy-vline
WA_FC00LST10M_STR-REFDOCNR sy-vline
WA_FC00LST10M_STR-REFRYEAR sy-vline
WA_FC00LST10M_STR-REFDOCLN sy-vline
WA_FC00LST10M_STR-REFDOCCT sy-vline
WA_FC00LST10M_STR-REFACTIV sy-vline
WA_FC00LST10M_STR-AWTYP sy-vline
WA_FC00LST10M_STR-AWORG sy-vline
WA_FC00LST10M_STR-LOGSYS sy-vline
WA_FC00LST10M_STR-UNIJRL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.