ABAP Select data from SAP table FBS_SX_COMP_RPLCTN_WORK_STRUC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FBS_SX_COMP_RPLCTN_WORK_STRUC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FBS_SX_COMP_RPLCTN_WORK_STRUC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FBS_SX_COMP_RPLCTN_WORK_STRUC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FBS_SX_COMP_RPLCTN_WORK_STRUC TYPE STANDARD TABLE OF FBS_SX_COMP_RPLCTN_WORK_STRUC,
      WA_FBS_SX_COMP_RPLCTN_WORK_STRUC TYPE FBS_SX_COMP_RPLCTN_WORK_STRUC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FBS_SX_COMP_RPLCTN_WORK_STRUC> TYPE FBS_SX_COMP_RPLCTN_WORK_STRUC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FBS_SX_COMP_RPLCTN_WORK_STRUC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FBS_SX_COMP_RPLCTN_WORK_STRUC
  INTO TABLE IT_FBS_SX_COMP_RPLCTN_WORK_STRUC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FBS_SX_COMP_RPLCTN_WORK_STRUC
*  INTO TABLE @DATA(IT_FBS_SX_COMP_RPLCTN_WORK_STRUC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FBS_SX_COMP_RPLCTN_WORK_STRUC INDEX 1 INTO DATA(WA_FBS_SX_COMP_RPLCTN_WORK_STRUC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FBS_SX_COMP_RPLCTN_WORK_STRUC ASSIGNING <FBS_SX_COMP_RPLCTN_WORK_STRUC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FBS_SX_COMP_RPLCTN_WORK_STRUC>-FEH_CONTEXT = 1.
<FBS_SX_COMP_RPLCTN_WORK_STRUC>-HANDLING_CLASS = 1.
<FBS_SX_COMP_RPLCTN_WORK_STRUC>-INBND_MSG_HEADER = 1.
<FBS_SX_COMP_RPLCTN_WORK_STRUC>-INBND_MSG_HEADER_BULK = 1.
<FBS_SX_COMP_RPLCTN_WORK_STRUC>-COREL_ID = 1.
ENDLOOP.

LOOP AT IT_FBS_SX_COMP_RPLCTN_WORK_STRUC INTO WA_FBS_SX_COMP_RPLCTN_WORK_STRUC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-CONTROL, sy-vline,
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-COMPANY, sy-vline,
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-CONTROL, sy-vline,
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-KEYY, sy-vline,
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-RCOMP, sy-vline,
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-COMPANY_DATA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FBS_SX_COMP_RPLCTN_WORK_STRUC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FBS_SX_COMP_RPLCTN_WORK_STRUC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FBS_SX_COMP_RPLCTN_WORK_STRUC INTO WA_FBS_SX_COMP_RPLCTN_WORK_STRUC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-RCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-RCOMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-RCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-RCOMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-RCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-RCOMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBS_SX_COMP_RPLCTN_WORK_STRUC-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR,
FEH_CONTEXT TYPE STRING,
HANDLING_CLASS TYPE STRING,
INBND_MSG_HEADER TYPE STRING,
INBND_MSG_HEADER_BULK TYPE STRING,
COREL_ID TYPE STRING,
CONTROL TYPE STRING,
COMPANY TYPE STRING,
CONTROL TYPE STRING,
KEYY TYPE STRING,
RCOMP TYPE STRING,
COMPANY_DATA TYPE STRING,
CONTROL TYPE STRING,
DB_ACTION TYPE STRING,
COMPL_TRANSMISSION TYPE STRING,
KEYY TYPE STRING,
RCOMP TYPE STRING,
T880 TYPE STRING,
MANDT TYPE STRING,
RCOMP TYPE STRING,
NAME1 TYPE STRING,
CNTRY TYPE STRING,
NAME2 TYPE STRING,
LANGU TYPE STRING,
STRET TYPE STRING,
POBOX TYPE STRING,
PSTLC TYPE STRING,
CITY TYPE STRING,
CURR TYPE STRING,
MODCP TYPE STRING,
GLSIP TYPE STRING,
RESTA TYPE STRING,
RFORM TYPE STRING,
ZWEIG TYPE STRING,
MCOMP TYPE STRING,
MCLNT TYPE STRING,
LCCOMP TYPE STRING,
STRT2 TYPE STRING,
INDPO TYPE STRING,
COMPANY_TEXT TYPE STRING,
COMPANY_DEFLT_CURR TYPE STRING,
COMPANY_ADDRESSES TYPE STRING,END OF T_EKKO_STR. DATA: WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-FEH_CONTEXT sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-HANDLING_CLASS sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-INBND_MSG_HEADER sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-INBND_MSG_HEADER_BULK sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-COREL_ID sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-CONTROL sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-COMPANY sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-CONTROL sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-KEYY sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-RCOMP sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-COMPANY_DATA sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-CONTROL sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-DB_ACTION sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-COMPL_TRANSMISSION sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-KEYY sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-RCOMP sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-T880 sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-MANDT sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-RCOMP sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-NAME1 sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-CNTRY sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-NAME2 sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-LANGU sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-STRET sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-POBOX sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-PSTLC sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-CITY sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-CURR sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-MODCP sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-GLSIP sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-RESTA sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-RFORM sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-ZWEIG sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-MCOMP sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-MCLNT sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-LCCOMP sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-STRT2 sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-INDPO sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-COMPANY_TEXT sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-COMPANY_DEFLT_CURR sy-vline
WA_FBS_SX_COMP_RPLCTN_WORK_STRUC_STR-COMPANY_ADDRESSES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.