ABAP Select data from SAP table FBICRC_S_COHIERY_GRP_NODE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FBICRC_S_COHIERY_GRP_NODE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FBICRC_S_COHIERY_GRP_NODE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FBICRC_S_COHIERY_GRP_NODE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FBICRC_S_COHIERY_GRP_NODE TYPE STANDARD TABLE OF FBICRC_S_COHIERY_GRP_NODE,
      WA_FBICRC_S_COHIERY_GRP_NODE TYPE FBICRC_S_COHIERY_GRP_NODE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FBICRC_S_COHIERY_GRP_NODE> TYPE FBICRC_S_COHIERY_GRP_NODE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FBICRC_S_COHIERY_GRP_NODE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FBICRC_S_COHIERY_GRP_NODE
  INTO TABLE IT_FBICRC_S_COHIERY_GRP_NODE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FBICRC_S_COHIERY_GRP_NODE
*  INTO TABLE @DATA(IT_FBICRC_S_COHIERY_GRP_NODE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FBICRC_S_COHIERY_GRP_NODE INDEX 1 INTO DATA(WA_FBICRC_S_COHIERY_GRP_NODE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FBICRC_S_COHIERY_GRP_NODE ASSIGNING <FBICRC_S_COHIERY_GRP_NODE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FBICRC_S_COHIERY_GRP_NODE>-UUID = 1.
<FBICRC_S_COHIERY_GRP_NODE>-HLEVEL = 1.
<FBICRC_S_COHIERY_GRP_NODE>-SETID = 1.
<FBICRC_S_COHIERY_GRP_NODE>-SHORTNAME = 1.
<FBICRC_S_COHIERY_GRP_NODE>-CLASS = 1.
ENDLOOP.

LOOP AT IT_FBICRC_S_COHIERY_GRP_NODE INTO WA_FBICRC_S_COHIERY_GRP_NODE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FBICRC_S_COHIERY_GRP_NODE-TYPE, sy-vline,
WA_FBICRC_S_COHIERY_GRP_NODE-XDYNAMIC, sy-vline,
WA_FBICRC_S_COHIERY_GRP_NODE-XUNIQ, sy-vline,
WA_FBICRC_S_COHIERY_GRP_NODE-ROLLNAME, sy-vline,
WA_FBICRC_S_COHIERY_GRP_NODE-ORGUNIT, sy-vline,
WA_FBICRC_S_COHIERY_GRP_NODE-DESCRIPT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FBICRC_S_COHIERY_GRP_NODE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FBICRC_S_COHIERY_GRP_NODE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FBICRC_S_COHIERY_GRP_NODE INTO WA_FBICRC_S_COHIERY_GRP_NODE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field OLANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_FBICRC_S_COHIERY_GRP_NODE-OLANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC_S_COHIERY_GRP_NODE-OLANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FBICRC_S_COHIERY_GRP_NODE_STR,
UUID TYPE STRING,
HLEVEL TYPE STRING,
SETID TYPE STRING,
SHORTNAME TYPE STRING,
CLASS TYPE STRING,
TYPE TYPE STRING,
XDYNAMIC TYPE STRING,
XUNIQ TYPE STRING,
ROLLNAME TYPE STRING,
ORGUNIT TYPE STRING,
DESCRIPT TYPE STRING,
AUTHGR TYPE STRING,
SNAME TYPE STRING,
PRTCLASS TYPE STRING,
LNAME TYPE STRING,
PMFLAG TYPE STRING,
XSUPPRESS TYPE STRING,
RVALUE TYPE STRING,
SETVARI TYPE STRING,
CREUSER TYPE STRING,
CREDATE TYPE STRING,
CRETIME TYPE STRING,
UPDUSER TYPE STRING,
UPDDATE TYPE STRING,
UPDTIME TYPE STRING,
OLANGU TYPE STRING,
NOTSHOW TYPE STRING,
STANDARD TYPE STRING,
XVALUES TYPE STRING,
TABFLDPNT TYPE STRING,
OLD_LINE TYPE STRING,
REF_SET TYPE STRING,
ACTION TYPE STRING,
MARK TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,END OF T_EKKO_STR. DATA: WA_FBICRC_S_COHIERY_GRP_NODE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-UUID sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-HLEVEL sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-SETID sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-SHORTNAME sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-CLASS sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-TYPE sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-XDYNAMIC sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-XUNIQ sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-ROLLNAME sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-ORGUNIT sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-DESCRIPT sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-AUTHGR sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-SNAME sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-PRTCLASS sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-LNAME sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-PMFLAG sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-XSUPPRESS sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-RVALUE sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-SETVARI sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-CREUSER sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-CREDATE sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-CRETIME sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-UPDUSER sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-UPDDATE sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-UPDTIME sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-OLANGU sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-NOTSHOW sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-STANDARD sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-XVALUES sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-TABFLDPNT sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-OLD_LINE sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-REF_SET sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-ACTION sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-MARK sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-VALID_FROM sy-vline
WA_FBICRC_S_COHIERY_GRP_NODE_STR-VALID_TO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.