ABAP Select data from SAP table FBICRC01010 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FBICRC01010 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FBICRC01010. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FBICRC01010 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FBICRC01010 TYPE STANDARD TABLE OF FBICRC01010,
      WA_FBICRC01010 TYPE FBICRC01010,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FBICRC01010> TYPE FBICRC01010.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FBICRC01010.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FBICRC01010
  INTO TABLE IT_FBICRC01010.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FBICRC01010
*  INTO TABLE @DATA(IT_FBICRC010102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FBICRC01010 INDEX 1 INTO DATA(WA_FBICRC010102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FBICRC01010 ASSIGNING <FBICRC01010>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FBICRC01010>-RCLNT = 1.
<FBICRC01010>-RPROC = 1.
<FBICRC01010>-RCOMP = 1.
<FBICRC01010>-SEQNR = 1.
<FBICRC01010>-RFCDES = 1.
ENDLOOP.

LOOP AT IT_FBICRC01010 INTO WA_FBICRC01010.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FBICRC01010-RFCDES_SEL, sy-vline,
WA_FBICRC01010-SLOCAL, sy-vline,
WA_FBICRC01010-SEPSEL, sy-vline,
WA_FBICRC01010-NONSAP, sy-vline,
WA_FBICRC01010-SLDNR, sy-vline,
WA_FBICRC01010-XFNAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FBICRC01010 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FBICRC01010 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FBICRC01010 INTO WA_FBICRC01010. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBICRC01010-RCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC01010-RCOMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBICRC01010-SLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC01010-SLDNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FBICRC01010_STR,
RCLNT TYPE STRING,
RPROC TYPE STRING,
RCOMP TYPE STRING,
SEQNR TYPE STRING,
RFCDES TYPE STRING,
RFCDES_SEL TYPE STRING,
SLOCAL TYPE STRING,
SEPSEL TYPE STRING,
NONSAP TYPE STRING,
SLDNR TYPE STRING,
XFNAM TYPE STRING,
XFNAM2 TYPE STRING,
XFNAM3 TYPE STRING,
DSOURCE TYPE STRING,
TTYPE TYPE STRING,
RFCDES_PUSH TYPE STRING,
XPRES TYPE STRING,
LFILE TYPE STRING,
USTRUC TYPE STRING,
CTYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FBICRC01010_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FBICRC01010_STR-RCLNT sy-vline
WA_FBICRC01010_STR-RPROC sy-vline
WA_FBICRC01010_STR-RCOMP sy-vline
WA_FBICRC01010_STR-SEQNR sy-vline
WA_FBICRC01010_STR-RFCDES sy-vline
WA_FBICRC01010_STR-RFCDES_SEL sy-vline
WA_FBICRC01010_STR-SLOCAL sy-vline
WA_FBICRC01010_STR-SEPSEL sy-vline
WA_FBICRC01010_STR-NONSAP sy-vline
WA_FBICRC01010_STR-SLDNR sy-vline
WA_FBICRC01010_STR-XFNAM sy-vline
WA_FBICRC01010_STR-XFNAM2 sy-vline
WA_FBICRC01010_STR-XFNAM3 sy-vline
WA_FBICRC01010_STR-DSOURCE sy-vline
WA_FBICRC01010_STR-TTYPE sy-vline
WA_FBICRC01010_STR-RFCDES_PUSH sy-vline
WA_FBICRC01010_STR-XPRES sy-vline
WA_FBICRC01010_STR-LFILE sy-vline
WA_FBICRC01010_STR-USTRUC sy-vline
WA_FBICRC01010_STR-CTYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.