ABAP Select data from SAP table FBICRC002T into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FBICRC002T table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FBICRC002T. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FBICRC002T table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FBICRC002T TYPE STANDARD TABLE OF FBICRC002T,
      WA_FBICRC002T TYPE FBICRC002T,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FBICRC002T> TYPE FBICRC002T.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FBICRC002T.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FBICRC002T
  INTO TABLE IT_FBICRC002T.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FBICRC002T
*  INTO TABLE @DATA(IT_FBICRC002T2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FBICRC002T INDEX 1 INTO DATA(WA_FBICRC002T2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FBICRC002T ASSIGNING <FBICRC002T>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FBICRC002T>-RCLNT = 1.
<FBICRC002T>-RLDNR = 1.
<FBICRC002T>-RRCTY = 1.
<FBICRC002T>-RVERS = 1.
<FBICRC002T>-RYEAR = 1.
ENDLOOP.

LOOP AT IT_FBICRC002T INTO WA_FBICRC002T.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FBICRC002T-ROBJNR, sy-vline,
WA_FBICRC002T-COBJNR, sy-vline,
WA_FBICRC002T-SOBJNR, sy-vline,
WA_FBICRC002T-RTCUR, sy-vline,
WA_FBICRC002T-DRCRK, sy-vline,
WA_FBICRC002T-RPMAX, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FBICRC002T you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FBICRC002T TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FBICRC002T INTO WA_FBICRC002T. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBICRC002T-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBICRC002T-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FBICRC002T-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBICRC002T-RCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-RCOMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RACCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBICRC002T-RACCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-RACCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RASSC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBICRC002T-RASSC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-RASSC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBICRC002T-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSLVT CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSLVT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSLVT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL01 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL02 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL03 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL04 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL05 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL06 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL07 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL07 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL07.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL08 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL08 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL08.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL09 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL09 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL09.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL10 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL10 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL10.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL11 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL12 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL12 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL12.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL13 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL13 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL13.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL14 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL14 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL14.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL15 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL15 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL15.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL16 CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FBICRC002T-TSL16 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBICRC002T-TSL16.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FBICRC002T_STR,
RCLNT TYPE STRING,
RLDNR TYPE STRING,
RRCTY TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
ROBJNR TYPE STRING,
COBJNR TYPE STRING,
SOBJNR TYPE STRING,
RTCUR TYPE STRING,
DRCRK TYPE STRING,
RPMAX TYPE STRING,
RCOMP TYPE STRING,
SEQNR TYPE STRING,
ROBUKRS TYPE STRING,
RACCT TYPE STRING,
RASSC TYPE STRING,
LOGSYS TYPE STRING,
RTYPE TYPE STRING,
TSLVT TYPE STRING,
TSL01 TYPE STRING,
TSL02 TYPE STRING,
TSL03 TYPE STRING,
TSL04 TYPE STRING,
TSL05 TYPE STRING,
TSL06 TYPE STRING,
TSL07 TYPE STRING,
TSL08 TYPE STRING,
TSL09 TYPE STRING,
TSL10 TYPE STRING,
TSL11 TYPE STRING,
TSL12 TYPE STRING,
TSL13 TYPE STRING,
TSL14 TYPE STRING,
TSL15 TYPE STRING,
TSL16 TYPE STRING,
CSPRED TYPE STRING,
TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_FBICRC002T_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FBICRC002T_STR-RCLNT sy-vline
WA_FBICRC002T_STR-RLDNR sy-vline
WA_FBICRC002T_STR-RRCTY sy-vline
WA_FBICRC002T_STR-RVERS sy-vline
WA_FBICRC002T_STR-RYEAR sy-vline
WA_FBICRC002T_STR-ROBJNR sy-vline
WA_FBICRC002T_STR-COBJNR sy-vline
WA_FBICRC002T_STR-SOBJNR sy-vline
WA_FBICRC002T_STR-RTCUR sy-vline
WA_FBICRC002T_STR-DRCRK sy-vline
WA_FBICRC002T_STR-RPMAX sy-vline
WA_FBICRC002T_STR-RCOMP sy-vline
WA_FBICRC002T_STR-SEQNR sy-vline
WA_FBICRC002T_STR-ROBUKRS sy-vline
WA_FBICRC002T_STR-RACCT sy-vline
WA_FBICRC002T_STR-RASSC sy-vline
WA_FBICRC002T_STR-LOGSYS sy-vline
WA_FBICRC002T_STR-RTYPE sy-vline
WA_FBICRC002T_STR-TSLVT sy-vline
WA_FBICRC002T_STR-TSL01 sy-vline
WA_FBICRC002T_STR-TSL02 sy-vline
WA_FBICRC002T_STR-TSL03 sy-vline
WA_FBICRC002T_STR-TSL04 sy-vline
WA_FBICRC002T_STR-TSL05 sy-vline
WA_FBICRC002T_STR-TSL06 sy-vline
WA_FBICRC002T_STR-TSL07 sy-vline
WA_FBICRC002T_STR-TSL08 sy-vline
WA_FBICRC002T_STR-TSL09 sy-vline
WA_FBICRC002T_STR-TSL10 sy-vline
WA_FBICRC002T_STR-TSL11 sy-vline
WA_FBICRC002T_STR-TSL12 sy-vline
WA_FBICRC002T_STR-TSL13 sy-vline
WA_FBICRC002T_STR-TSL14 sy-vline
WA_FBICRC002T_STR-TSL15 sy-vline
WA_FBICRC002T_STR-TSL16 sy-vline
WA_FBICRC002T_STR-CSPRED sy-vline
WA_FBICRC002T_STR-TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.