ABAP Select data from SAP table FARR_S_FULFILLMENT_ATTR_WS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FARR_S_FULFILLMENT_ATTR_WS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FARR_S_FULFILLMENT_ATTR_WS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FARR_S_FULFILLMENT_ATTR_WS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FARR_S_FULFILLMENT_ATTR_WS TYPE STANDARD TABLE OF FARR_S_FULFILLMENT_ATTR_WS,
      WA_FARR_S_FULFILLMENT_ATTR_WS TYPE FARR_S_FULFILLMENT_ATTR_WS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FARR_S_FULFILLMENT_ATTR_WS> TYPE FARR_S_FULFILLMENT_ATTR_WS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FARR_S_FULFILLMENT_ATTR_WS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FARR_S_FULFILLMENT_ATTR_WS
  INTO TABLE IT_FARR_S_FULFILLMENT_ATTR_WS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FARR_S_FULFILLMENT_ATTR_WS
*  INTO TABLE @DATA(IT_FARR_S_FULFILLMENT_ATTR_WS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FARR_S_FULFILLMENT_ATTR_WS INDEX 1 INTO DATA(WA_FARR_S_FULFILLMENT_ATTR_WS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FARR_S_FULFILLMENT_ATTR_WS ASSIGNING <FARR_S_FULFILLMENT_ATTR_WS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FARR_S_FULFILLMENT_ATTR_WS>-RECON_KEY = 1.
<FARR_S_FULFILLMENT_ATTR_WS>-EVENT_DATE = 1.
<FARR_S_FULFILLMENT_ATTR_WS>-EVENT_TIME = 1.
<FARR_S_FULFILLMENT_ATTR_WS>-DEFERRAL_CAT = 1.
<FARR_S_FULFILLMENT_ATTR_WS>-EVENT_TYPE = 1.
ENDLOOP.

LOOP AT IT_FARR_S_FULFILLMENT_ATTR_WS INTO WA_FARR_S_FULFILLMENT_ATTR_WS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FARR_S_FULFILLMENT_ATTR_WS-REPORTED_QTY, sy-vline,
WA_FARR_S_FULFILLMENT_ATTR_WS-REPORTED_QTY_UNT, sy-vline,
WA_FARR_S_FULFILLMENT_ATTR_WS-ACTUAL_QTY, sy-vline,
WA_FARR_S_FULFILLMENT_ATTR_WS-ACTUAL_QTY_UNT, sy-vline,
WA_FARR_S_FULFILLMENT_ATTR_WS-REPORTED_QTY_DIFF, sy-vline,
WA_FARR_S_FULFILLMENT_ATTR_WS-GROUP_GUID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FARR_S_FULFILLMENT_ATTR_WS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FARR_S_FULFILLMENT_ATTR_WS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FARR_S_FULFILLMENT_ATTR_WS INTO WA_FARR_S_FULFILLMENT_ATTR_WS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit RRQUT, internal->external for field REPORTED_QTY CALL FUNCTION 'CONVERSION_EXIT_RRQUT_OUTPUT' EXPORTING input = WA_FARR_S_FULFILLMENT_ATTR_WS-REPORTED_QTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_FULFILLMENT_ATTR_WS-REPORTED_QTY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field REPORTED_QTY_UNT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FARR_S_FULFILLMENT_ATTR_WS-REPORTED_QTY_UNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_FULFILLMENT_ATTR_WS-REPORTED_QTY_UNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit RRQUT, internal->external for field ACTUAL_QTY CALL FUNCTION 'CONVERSION_EXIT_RRQUT_OUTPUT' EXPORTING input = WA_FARR_S_FULFILLMENT_ATTR_WS-ACTUAL_QTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_FULFILLMENT_ATTR_WS-ACTUAL_QTY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ACTUAL_QTY_UNT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FARR_S_FULFILLMENT_ATTR_WS-ACTUAL_QTY_UNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_FULFILLMENT_ATTR_WS-ACTUAL_QTY_UNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit RRQUT, internal->external for field REPORTED_QTY_DIFF CALL FUNCTION 'CONVERSION_EXIT_RRQUT_OUTPUT' EXPORTING input = WA_FARR_S_FULFILLMENT_ATTR_WS-REPORTED_QTY_DIFF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_FULFILLMENT_ATTR_WS-REPORTED_QTY_DIFF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FARR_S_FULFILLMENT_ATTR_WS_STR,
RECON_KEY TYPE STRING,
EVENT_DATE TYPE STRING,
EVENT_TIME TYPE STRING,
DEFERRAL_CAT TYPE STRING,
EVENT_TYPE TYPE STRING,
REPORTED_QTY TYPE STRING,
REPORTED_QTY_UNT TYPE STRING,
ACTUAL_QTY TYPE STRING,
ACTUAL_QTY_UNT TYPE STRING,
REPORTED_QTY_DIFF TYPE STRING,
GROUP_GUID TYPE STRING,
AMOUNT TYPE STRING,
AMOUNT_CURK TYPE STRING,
COMPOUND_FULFILL_GROUP_GUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_FARR_S_FULFILLMENT_ATTR_WS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-RECON_KEY sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-EVENT_DATE sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-EVENT_TIME sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-DEFERRAL_CAT sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-EVENT_TYPE sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-REPORTED_QTY sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-REPORTED_QTY_UNT sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-ACTUAL_QTY sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-ACTUAL_QTY_UNT sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-REPORTED_QTY_DIFF sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-GROUP_GUID sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-AMOUNT sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-AMOUNT_CURK sy-vline
WA_FARR_S_FULFILLMENT_ATTR_WS_STR-COMPOUND_FULFILL_GROUP_GUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.