ABAP Select data from SAP table FAP_OC_S_ACTION_VOID_NOTUSED into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAP_OC_S_ACTION_VOID_NOTUSED table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAP_OC_S_ACTION_VOID_NOTUSED. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FAP_OC_S_ACTION_VOID_NOTUSED table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FAP_OC_S_ACTION_VOID_NOTUSED TYPE STANDARD TABLE OF FAP_OC_S_ACTION_VOID_NOTUSED,
      WA_FAP_OC_S_ACTION_VOID_NOTUSED TYPE FAP_OC_S_ACTION_VOID_NOTUSED,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FAP_OC_S_ACTION_VOID_NOTUSED> TYPE FAP_OC_S_ACTION_VOID_NOTUSED.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FAP_OC_S_ACTION_VOID_NOTUSED.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FAP_OC_S_ACTION_VOID_NOTUSED
  INTO TABLE IT_FAP_OC_S_ACTION_VOID_NOTUSED.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FAP_OC_S_ACTION_VOID_NOTUSED
*  INTO TABLE @DATA(IT_FAP_OC_S_ACTION_VOID_NOTUSED2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FAP_OC_S_ACTION_VOID_NOTUSED INDEX 1 INTO DATA(WA_FAP_OC_S_ACTION_VOID_NOTUSED2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FAP_OC_S_ACTION_VOID_NOTUSED ASSIGNING <FAP_OC_S_ACTION_VOID_NOTUSED>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAP_OC_S_ACTION_VOID_NOTUSED>-ZBUKR = 1.
<FAP_OC_S_ACTION_VOID_NOTUSED>-HBKID = 1.
<FAP_OC_S_ACTION_VOID_NOTUSED>-HKTID = 1.
<FAP_OC_S_ACTION_VOID_NOTUSED>-CHECF = 1.
<FAP_OC_S_ACTION_VOID_NOTUSED>-CHECT = 1.
ENDLOOP.

LOOP AT IT_FAP_OC_S_ACTION_VOID_NOTUSED INTO WA_FAP_OC_S_ACTION_VOID_NOTUSED.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FAP_OC_S_ACTION_VOID_NOTUSED-VOIDR, sy-vline,
WA_FAP_OC_S_ACTION_VOID_NOTUSED-VOIDD, sy-vline,
WA_FAP_OC_S_ACTION_VOID_NOTUSED-VOIDCOMMENTS, sy-vline,
WA_FAP_OC_S_ACTION_VOID_NOTUSED-CHECKTYPE, sy-vline,
WA_FAP_OC_S_ACTION_VOID_NOTUSED-RZAWE, sy-vline,
ENDLOOP. *Add any further fields from structure WA_FAP_OC_S_ACTION_VOID_NOTUSED you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAP_OC_S_ACTION_VOID_NOTUSED TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAP_OC_S_ACTION_VOID_NOTUSED INTO WA_FAP_OC_S_ACTION_VOID_NOTUSED. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAP_OC_S_ACTION_VOID_NOTUSED_STR,
ZBUKR TYPE STRING,
HBKID TYPE STRING,
HKTID TYPE STRING,
CHECF TYPE STRING,
CHECT TYPE STRING,
VOIDR TYPE STRING,
VOIDD TYPE STRING,
VOIDCOMMENTS TYPE STRING,
CHECKTYPE TYPE STRING,
RZAWE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR-ZBUKR sy-vline
WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR-HBKID sy-vline
WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR-HKTID sy-vline
WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR-CHECF sy-vline
WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR-CHECT sy-vline
WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR-VOIDR sy-vline
WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR-VOIDD sy-vline
WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR-VOIDCOMMENTS sy-vline
WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR-CHECKTYPE sy-vline
WA_FAP_OC_S_ACTION_VOID_NOTUSED_STR-RZAWE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.