ABAP Select data from SAP table FAGL_EMU_S_KEY6 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAGL_EMU_S_KEY6 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAGL_EMU_S_KEY6. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FAGL_EMU_S_KEY6 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FAGL_EMU_S_KEY6 TYPE STANDARD TABLE OF FAGL_EMU_S_KEY6,
      WA_FAGL_EMU_S_KEY6 TYPE FAGL_EMU_S_KEY6,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FAGL_EMU_S_KEY6> TYPE FAGL_EMU_S_KEY6.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FAGL_EMU_S_KEY6.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FAGL_EMU_S_KEY6
  INTO TABLE IT_FAGL_EMU_S_KEY6.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FAGL_EMU_S_KEY6
*  INTO TABLE @DATA(IT_FAGL_EMU_S_KEY62).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FAGL_EMU_S_KEY6 INDEX 1 INTO DATA(WA_FAGL_EMU_S_KEY62).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FAGL_EMU_S_KEY6 ASSIGNING <FAGL_EMU_S_KEY6>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAGL_EMU_S_KEY6>-BELNR = 1.
<FAGL_EMU_S_KEY6>-GJAHR = 1.
<FAGL_EMU_S_KEY6>-BUZEI = 1.
<FAGL_EMU_S_KEY6>-LDGRP = 1.
<FAGL_EMU_S_KEY6>-BUDAT = 1.
ENDLOOP.

LOOP AT IT_FAGL_EMU_S_KEY6 INTO WA_FAGL_EMU_S_KEY6.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FAGL_EMU_S_KEY6-HKONT, sy-vline,
WA_FAGL_EMU_S_KEY6-AUGDT, sy-vline,
WA_FAGL_EMU_S_KEY6-SHKZG, sy-vline,
WA_FAGL_EMU_S_KEY6-PSWBT, sy-vline,
WA_FAGL_EMU_S_KEY6-DMBTR, sy-vline,
WA_FAGL_EMU_S_KEY6-DMBE2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FAGL_EMU_S_KEY6 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAGL_EMU_S_KEY6 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAGL_EMU_S_KEY6 INTO WA_FAGL_EMU_S_KEY6. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAGL_EMU_S_KEY6-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGL_EMU_S_KEY6-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FAGL_EMU_S_KEY6-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGL_EMU_S_KEY6-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAGL_EMU_S_KEY6-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGL_EMU_S_KEY6-HKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field PSWBT CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAGL_EMU_S_KEY6-PSWBT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGL_EMU_S_KEY6-PSWBT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field DMBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAGL_EMU_S_KEY6-DMBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGL_EMU_S_KEY6-DMBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field DMBE2 CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAGL_EMU_S_KEY6-DMBE2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGL_EMU_S_KEY6-DMBE2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field DMBE3 CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAGL_EMU_S_KEY6-DMBE3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGL_EMU_S_KEY6-DMBE3.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAGL_EMU_S_KEY6_STR,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BUZEI TYPE STRING,
LDGRP TYPE STRING,
BUDAT TYPE STRING,
HKONT TYPE STRING,
AUGDT TYPE STRING,
SHKZG TYPE STRING,
PSWBT TYPE STRING,
DMBTR TYPE STRING,
DMBE2 TYPE STRING,
DMBE3 TYPE STRING,
SI_ENTRY TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAGL_EMU_S_KEY6_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAGL_EMU_S_KEY6_STR-BELNR sy-vline
WA_FAGL_EMU_S_KEY6_STR-GJAHR sy-vline
WA_FAGL_EMU_S_KEY6_STR-BUZEI sy-vline
WA_FAGL_EMU_S_KEY6_STR-LDGRP sy-vline
WA_FAGL_EMU_S_KEY6_STR-BUDAT sy-vline
WA_FAGL_EMU_S_KEY6_STR-HKONT sy-vline
WA_FAGL_EMU_S_KEY6_STR-AUGDT sy-vline
WA_FAGL_EMU_S_KEY6_STR-SHKZG sy-vline
WA_FAGL_EMU_S_KEY6_STR-PSWBT sy-vline
WA_FAGL_EMU_S_KEY6_STR-DMBTR sy-vline
WA_FAGL_EMU_S_KEY6_STR-DMBE2 sy-vline
WA_FAGL_EMU_S_KEY6_STR-DMBE3 sy-vline
WA_FAGL_EMU_S_KEY6_STR-SI_ENTRY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.